Home > Product Details NAP Features Single Phase 250 VAC Selectable leakage current Quick and easy push-down terminal. Just connect the wires, push down and tighten the screws with a screwdriver. DIN rail installation (option) Outside Impulse high-attenuation type RoHS Compliant Rated Rated Voltage Current Model V A NAP-06-472 AC 1- 250 / DC250 6 NAP-10-472 AC 1- 250 / DC250 10 NAP-16-472 AC 1- 250 / DC250 16 NAP-20-472 AC 1- 250 / DC250 20 NAP-30-472 AC 1- 250 / DC250 30 NAP-04-472 AC 1- 250 / DC250 4 Ordering information High-voltage pulses high-attenuation type NAP -10 -472 -O NAP series 1 2 3 4 1Model Name 2Rated Current 3Line to ground capacitor code:See table 1.1. table1.1 Line to ground capacitor code Line to ground Leakage Current Code capacitor (Input 125/250V 60Hz) (nominal value) 000 5 A/ 10 A max Not Provided 101 12.5 A/ 25 A max 100pF 221 25 A/ 50 A max 220pF 331 37.5 A/ 75 A max 330pF 471 50 A/ 100 A max 470pF 681 75.5 A/ 150 A max 680pF 102 0.13 mA/ 0.25mA max 1000pF 222 0.25 mA/ 0.5 mA max 2200pF 332 0.38 mA/ 0.75mA max 3300pF 472 0.5 mA/ 1.0 mA max 4700pF The terminal cover is retracted inside the unit DIN rail installation type is option *1 When the line to ground capacitor code is different, the attenuation characteristic is different. 4Options D:DIN rail installation type * The dimensions change when the option is set. Refer to External view. Features of NAP series High-voltage pulses high-attenuation type - Single Phase 250 VAC - Quick and easy push-down terminal Just connect the wires, push down and tighten the screws with a screwdriver Specifications No. Items NAP-04-472 NAP-06-472 NAP-10-472 NAP-16-472 NAP-20-472 NAP-30-472 1 Rated Voltage V AC 1f 250 / DC250 2 Rated Current A 4 6 10162030 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW minute at room temperature and humidity 5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max 6 Voltage drop 1.0V max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 2 11 Vibration 10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis 2 12 Impact 196.1m/s (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN133200 VDE0565 Teil3-1, ENEC (At only AC input) 14 Case size (without projection) /Mass 53X41X92 mm (WXHXD) /300g max (Option : -D refer to external view) Circuit Diagram Derating Curve Case 100 80 1 3 60 CY LOAD LINE 40 CY 20 2 4 Noise 0 Filter -40 -30 -20 40 50 55 60 70 80 90 Ambient Temperature C CY : Line to ground capacitor : Mounting Plate I-4 Load Factor %