AC-DC Power Supplies Medical Type Medical Power World wide Cost Safety EMI Inrush OCP OVP electric Factor Effective Approvals current PJMA equipment Correction limiting PJMA-series Feature EMI 4kV isolation Complies with FCC-B, CISPR32-B, EN55011-B, EN55032-B, Economical design VCCI-B Suitable for BF application (Output-FG : 1MOPP, lnput-Output : 2MOPP) EMS Compliance : EN61204-3, EN61000-6-2 Wide temperature range (-20C to +70C, Derating is required) IEC60601-1-2 (2014), IEC60601-1-2 (2015) Harmonic attenuator (Complies with IEC61000-3-2 class A) EN61000-4-2 Universal input (AC85 - 264V, Derating is required) EN61000-4-3 Low power consumption at no load EN61000-4-4 EN61000-4-5 Safety agency approvals EN61000-4-6 EN61000-4-8 ANSI/AAMI ES60601-1, EN60601-1 3rd EN61000-4-11 5-year warranty (See Instruction Manual) CE marking Low Voltage Directive RoHS Directive October 15, 2021 PJMA-1 Ordering information AC-DC Power Supplies Medical Type PJM A 300 F -O -O PJMA300F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output NAC-06-472 3 Output wattage 4 Universal input 5 Output voltage *6 6 Optional C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment High voltage pulse noise type : NAP series R : Remote on/off Low leakage current type : NAM series (Required external power source) * A higher current rating EMI/EMC filter F4 : Low speed fan may be recommended in view of the other devices that could be connected See 5.1 in Instruction Manual. in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL PJMA300F-12 PJMA300F-24 PJMA300F-36 PJMA300F-48 VOLTAGE V AC85 - 264 1f (Output derating is required at AC85V - 100V. Refer to Derating and instruction manual 1.1) ACIN 100V 3.9typ (Io=100%) CURRENT A ACIN 115V 3.3typ (Io=100%) ACIN 230V 1.7typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 63) ACIN 100V 79typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) 82typ (Io=100%) EFFICIENCY % ACIN 115V 80typ (Io=100%) 83typ (Io=100%) 83typ (Io=100%) 83typ (Io=100%) INPUT ACIN 230V 82typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 86typ (Io=100%) ACIN 100V 0.99typ (Io=100%) POWER FACTOR ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) ACIN 100V 20typ (Io=100%) TA=25C at cold start INRUSH CURRENT A ACIN 115V 20typ (Io=100%) TA=25C at cold start ACIN 230V 40typ (Io=100%) TA=25C at cold start LEAKAGE CURRENT mA 0.3max (ACIN 240V, 60Hz, Io=100%) VOLTAGE V 12 24 36 48 ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to Derating) CURRENT A ACIN 100V-264V 25 12.5 8.4 6.3 ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to Derating) WATTAGE W ACIN 100V-264V 300 300 302.4 302.4 LINE REGULATION mV *3 48max 96max 144max 192max *3 LOAD REGULATION mV 100max 150max 150max 300max 0 to +50C 120max 120max 150max 150max RIPPLE mVp-p *1 -10 to 0C 160max 160max 160max 400max OUTPUT 0 to +50C 150max 150max 200max 200max RIPPLE NOISE mVp-p *1 -10 to 0C 180max 180max 240max 500max 0 to +50C 120max 240max 360max 480max TEMPERATURE REGULATION mV -10 to +50C 180max 290max 440max 600max *2 DRIFT mV 48max 96max 144max 192max START-UP TIME ms 300typ (ACIN 100V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 10.80 to 13.20 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 OUTPUT VOLTAGE SETTING V 12.00 to 12.48 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION V 13.80 to 16.80 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 PROTECTION CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) *9 INPUT-OUTPUT RC AC4,000V 1minute, Cutoff=20mA, 2MOPP DC500V 50MWmin INPUT-FG AC2,000V 1minute, Cutoff=20mA, 1MOPP DC500V 50MWmin ISOLATION *9 OUTPUT RC-FG AC1,500V 1minute, Cutoff=20mA, 1MOPP DC500V 50MWmin OUTPUT-RC *9 AC500V 1minute, Cutoff=20mA, DC500V 50MWmin *4 OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +70C (Refer to Derating), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60 minutes each along X, Y and Z axes 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axes AGENCY APPROVALS ANSI/AAMI ES60601-1, EN60601-1 3rd SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS HARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 class A October 15, 2021 PJMA-2