. Ordering information DC-DC Converters Bus Converter Power Module Value-added Type SNDH S 50 A 05 -O SNDHS50A 1 2 3 4 5 6 1 Series name R 2 Single output 3 Output wattage 4 A : DC60-160V 5 Output voltage 6 Optional C : with Coating R : with Remote ON/OFF Please refer to Instruction manual 7. MODEL SNDHS50A05 SNDHS50A12 SNDHS50A15 SNDHS50A24 MAX OUTPUT WATTAGE W 50.0 50.4 51.0 50.4 DC OUTPUT 5V 10A 12V 4.2A 15V 3.4A 24V 2.1A SPECIFICATIONS MODEL SNDHS50A05 SNDHS50A12 SNDHS50A15 SNDHS50A24 VOLTAGE V DC60 - 160 INPUT CURRENT A *1 0.55typ 0.55typ 0.55typ 0.55typ *1 83.0typ 85.0typ 85.0typ 85.0typ EFFICIENCY % VOLTAGE V 5 121524 CURRENT A 10 4.2 3.4 2.1 LINE REGULATION mV 10max 24max 30max 48max LOAD REGULATION mV 150max 100max 100max 100max 0 to +95C *2 80max 120max 120max 120max RIPPLE mVp-p *2 120max 150max 150max 150max -20 to 0C *2 0 to 15% Load 160max 240max 240max 240max 0 to +95C *2 160max 200max 200max 200max OUTPUT RIPPLE NOISE mVp-p *2 250max 280max 280max 280max -20 to 0C *2 0 to 15% Load 300max 300max 300max 300max 0 to +50C 50max 120max 150max 240max TEMPERATURE REGULATION mV 100max 240max 300max 480max -20 to +95C *3 DRIFT mV 20max 40max 60max 90max START-UP TIME ms 200max (DCIN 110V, Io=100%) *4 4.50 - 5.50 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 OUTPUT VOLTAGE ADJUSTMENT RANGE V OUTPUT VOLTAGE SETTING V 5.00 - 5.15 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80 CIRCUIT AND REMOTE SENSING None OTHERS REMOTE ON/OFF (RC) Optional (Required external power source) SNDHS *5 INPUT-OUTPUT, RC AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) INPUT-FG AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MW min (2015C) ISOLATION *5 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OUTPUT, RC-FG *5 OUTPUT-RC AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (2015C) *6 OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +95C (Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 SAFETY CONDUCTED NOISE (at only DC input) Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A CASE SIZE/WEIGHT 61.5X44.5X150mm 2.42X1.75X5.91 inches (WXHXD) / 270g max OTHERS COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1 At rated input(DC110V) and rated load. *2 Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm 5.91 inches from output terminal. Refer to the instruction manual 3.2. *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 Refer to the instruction manual 4.6. *5 Applicable when remote control (optional) is added. *6 Refer to the instruction manual 6.2. SNDHS-2 SNDHS50A External view 10 0.39 10 20.75 4-f0.177 4-f4.5 0.82 0.39 Mounting hole Terminal cover 8.6 M4 Connector for remote ON/OFF 0.34 -Vin (optional) +Vin FG TB1 Name plate 16.75 0.66 Voltage adjust CN2 2 PointB 1 TB2 +Vout -Vout Terminal cover 8.6 PointA 0.34 M4 25.65 10 1.01 0.39 5.08 0.5 51.34 2.020.02 Tolerance : 1 0.04 0.20 Weight : 270g max 61.5 2.42 Dimensions in mm, =inches PCB material/thickness : FR-4 / 1.6mm 0.06 Power module Base plate material/thickness : Alminum / 3.0mm 0.12 (DHS50A) Mounting torque : 1.6N m (16.9kgf cm) max - - Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 f0.177 hole. Base plate SNDHS SNDHS-3 150 5.91 5.08 139.840.5 0.2 5.510.02 38.25 44.5 max 1.51 1.75 max 8.7 132.81 0.34 5.23