AC-DC Power Supplies PCB Mount Type Isolated Safety OCP OVP World wide Approvals TUHS-series Feature P.C.board mount AC-DC Converter Design flexibility for Hold-Up time and expected life Small size Built-in overcurrent and overvoltage protection circuits High efficiency by synchronous rectification technology (TUHS25) Not built-in aluminum and tantalum electrolytic capacitor CE marking Low voltage directive RoHS Directive Safety Approval UL60950-1, C-UL, EN60950-1 5-year warranty June 26, 2020 TUHS-1Ordering information AC-DC Power Supplies PCB Mount Type TUH S 3 F 05 TUHS3 1 2 3 4 5 1 Series name R 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage Class *Avoid short circuit between +BC and -BC. It may cause the failure of inside components. *To use TUHS, external components are required. Refer to the instruction manual for details. MODEL TUHS3F05 TUHS3F12 TUHS3F15 TUHS3F24 MAX OUTPUT WATTAGE W 3.00 3.00 3.00 3.12 DC OUTPUT 5V 0.6A 12V 0.25A 15V 0.2A 24V 0.13A SPECIFICATIONS MODEL TUHS3F05 TUHS3F12 TUHS3F15 TUHS3F24 VOLTAGE V AC85 - 264 1f DC120 - 370 ACIN 100V 0.08typ (Io=100%) CURRENT A ACIN 200V 0.05typ (Io=100%) INPUT FREQUENCY Hz 50/60 (47 - 63) ACIN 100V 79typ 81typ 81typ 81typ EFFICIENCY % ACIN 200V 78typ 79typ 79typ 79typ INRUSH CURRENT Limited by external components VOLTAGE V 5 12 15 24 CURRENT A 0.6 0.25 0.2 0.13 LINE REGULATION mV 20max 48max 60max 96max LOAD REGULATION mV 40max 100max 120max 150max 30 to 100% Load *1 120max 160max 160max 200max RIPPLE mVp-p 0 to 30% Load 400max 480max 480max 580max AC85V - 240V *1 OUTPUT *1 30 to 100% Load 160max 200max 200max 240max RIPPLE 0 to 30% Load NOISE mVp-p 480max 560max 560max 660max *1 AC85V - 240V 0 to +85C 100max 180max 240max 360max TEMPERATURE REGULATION mV -40 to +85C 150max 270max 360max 480max *2 DRIFT mV 20max 48max 60max 96max OUTPUT VOLTAGE SETTING V 4.90 - 5.30 11.40 - 12.60 14.25 - 15.75 23.00 - 25.00 OVERCURRENT PROTECTION Works over 105% of rating and recover automatically PROTECTION CIRCUIT AND OTHERS OVERVOLTAGE PROTECTION V 5.50 - 8.00 13.20 - 19.20 16.50 - 24.00 26.40 - 38.40 ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +85C, 20 - 95%RH (Non condensing) (Refer to Derating), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 49.0m/s (5G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1 SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B *3 REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter) CASE SIZE/WEIGHT 28.7X12.7X17.5mm 1.13X0.50X0.69 inches (WXHXD) / 15g max OTHERS COOLING METHOD Convection / Forced air *1 Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value. *3 Do not ground secondly circuit, in case of a standard adapted. * Measured with 18F capasitor as Cbc. June 26, 2020 TUHS-2