AC-DC Power Supplies Power Module Type Power Safety Isolated OCP OVP World wide Inrush Factor Approvals current Correction limiting TUXS-series Feature AC-DC Power Module Type Converter Harmonic attenuator (Complies with IEC61000-3-2 class A) Small size Built-in overcurrent, overvoltage and thermal protection circuits Mounting hole (M3 tapped) High efficiency 94% CE marking Low voltage directive RoHS Directive Safety Approval UL60950-1, C-UL, EN60950-1 5-year warranty June 17, 2021 TUXS-1Ordering information AC-DC Power Supplies Power Module Type TUX S 150 F 50 -O TUXS150F 1 2 3 4 5 6 1 Series name R 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage 6 Optional T : with Mounting hole (f3.4 thru) N : Auto restart in protection circuit working *Avoid short circuit between +BC and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. MODEL TUXS150F50 MAX OUTPUT WATTAGE W 150.0 DC OUTPUT 50V 3A SPECIFICATIONS MODEL TUXS150F50 VOLTAGE V AC85 - 264 1f ACIN 100V 1.70typ (Io=100%) CURRENT A ACIN 200V 0.80typ (Io=100%) FREQUENCY Hz 50/60 (45 - 66) ACIN 100V 93typ INPUT EFFICIENCY % ACIN 200V 94typ ACIN 100V 0.96typ POWER FACTOR (Io=100%) ACIN 200V 0.93typ INRUSH CURRENT Limited by external components (Thermistor) LEAKAGE CURRENT mA 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) VOLTAGE V 50 CURRENT A 3 LINE REGULATION mV 100max LOAD REGULATION mV 100max *1 -20 to +100C 200max RIPPLE mVp-p *1 -40 to -20C 300max *1 -20 to +100C 200max OUTPUT RIPPLE NOISE mVp-p *1 -40 to -20C 300max 0 to +100C 500max TEMPERATURE REGULATION mV -40 to +100C 1000max DRIFT mV *2 200max Fixed (TRM pin open), adjustable by external resistor or external signal OUTPUT VOLTAGE ADJUSTMENT RANGE V 45.0 - 55.0 OUTPUT VOLTAGE SETTING V 49.2 - 50.8 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 57.5 - 67.5 CIRCUIT AND REMOTE SENSING Not provided OTHERS REMOTE ON/OFF Not provided INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) OUTPUT-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to Derating), 4,000m (13,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 49.0m/s (5G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 SAFETY AND *3 NOISE REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) CASE SIZE/WEIGHT 76.2X28.5X50.8mm 3.0X1.12X2.0 inches (WXHXD) / 150g max OTHERS COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1 Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Please contact us about another class. June 17, 2021 TUXS-2