Additional Resources: Product Page date 02/07/2020 page 1 of 7 SERIES: CBM-75B DESCRIPTION: DC BLOWER FEATURES ball bearing design multiple speed options for different cooling needs 75 x 75 mm frame auto restart protection standard on all models 4 input input input rated air static noise MODEL 1 1 1 2 3 voltage current power speed flow pressure rated range max max typ max (Vdc) (Vdc) (mA) (W) (RPM10%) (CFM) (inch H O) (dBA) 2 CBM-7530B-119 12 6~13.8 80 1.0 1900 7.5 0.15 28.0 CBM-7530B-124 12 6~13.8 130 1.6 2400 9.6 0.27 33.9 CBM-7530B-130 12 6~13.8 230 2.8 3000 12.3 0.48 40.5 CBM-7530B-134 12 6~13.8 300 3.6 3400 13.6 0.60 43.5 CBM-7530B-219 24 10~27.6 50 1.2 1900 7.5 0.15 28.0 CBM-7530B-224 24 10~27.6 80 1.9 2400 9.6 0.27 33.9 CBM-7530B-230 24 10~27.6 140 3.4 3000 12.3 0.48 40.5 CBM-7530B-234 24 10~27.6 170 4.1 3400 13.6 0.60 43.5 Notes: 1. At rated voltage, 25C, 0 inch H 0 static pressure, after 10 minutes 2 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H 0 static pressure 2 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. All specifications are measured at 25C, 65% relative humidity unless otherwise specified. cuidevices.com DISCONTINUEDAdditional Resources: Product Page CUI Devices SERIES: CBM-75B DESCRIPTION: DC BLOWER date 02/07/2020 page 2 of 7 INPUT parameter conditions/description min typ max units 12 Vdc input models 6 12 13.8 Vdc operating input voltage 24 Vdc input models 10 24 27.6 Vdc 12 Vdc input models 6 Vdc starting voltage 24 Vdc input models 10 Vdc 1 PERFORMANCE parameter conditions/description min typ max units rated speed at rated voltage, 25C, after 10 minutes 1900 3400 RPM air flow at 0 inch H O, see performance curves 7.5 13.6 CFM 2 static pressure at 0 CFM, see performance curves 0.15 0.60 inch H O 2 noise at 1 m 28.0 43.5 dBA Note: 1. See Model section on page 1 for specific v alues. PROTECTIONS parameter conditions/description min typ max units when the fan motor is locked by an external force, the device will temporarily turn off electrical power auto restart to the motor and restart automatically when the locked rotor condition is released SAFETY & COMPLIANCE parameter conditions/description min typ max units at 500 Vdc between internal stator and positive insulation resistance of frame 10 M lead wire apply 500 Vac for 1 minute between housing and dielectric strength positive lead wire safety approvals UL/cUL 507, TUV (EN 60950-1) EMI/EMC EN 61000-6-1:2007, EN 61000-6-3:2007+A1 life expectancy at 40C, 65% RH 70,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 C storage temperature -40 70 C cuidevices.com DISCONTINUED