Additional Resources: Product Page 3D Model date 02/07/2020 page 1 of 5 SERIES: CFM-50 DESCRIPTION: DC AXIAL FAN FEATURES 50 x 50 mm frame high fan speed for greater air flow dual ball bearing construction auto restart protection standard on all models input input input rated air static noise MODEL 1 2 voltage current power speed flow pressure rated range typ max max typ max (Vdc) (Vdc) (A) (A) (W) (RPM) (CFM) (inch H O) (dBA) 2 CFM-5010-03 5 4~5.75 0.21 0.28 1.4 6,100 16.07 0.20 37.2 CFM-5010-13 12 6~13.8 0.11 0.14 1.68 6,100 16.07 0.20 37.0 Notes: 1. At 0 inch H 0 static pressure. 2 2. At 0 CFM airflow. PART NUMBER KEY CFM-5010 - X 3 - XX - CXX Base Number Reserved for Custom Configurations Input Voltage Fan Signals 0 = 5 Vdc 10 = no signals 1 = 12 Vdc 20 = tachometer signal 22 = tachometer signal / PWM control signal cuidevices.comAdditional Resources: Product Page 3D Model CUI Devices SERIES: CFM-50 DESCRIPTION: DC AXIAL FAN date 02/07/2020 page 2 of 5 INPUT parameter conditions/description min typ max units 5 Vdc input models 4 5 5.75 Vdc operating input voltage 12 Vdc input models 6 12 13.8 Vdc 5 Vdc input models 0.21 0.28 A current 12 Vdc input models 0.11 0.14 A 5 Vdc input models 1.05 1.4 W power 12 Vdc input models 1.32 1.68 W at 25C starting voltage 5 Vdc input models 4 Vdc 12 Vdc input models 6 Vdc PERFORMANCE parameter conditions/description min typ max units rated speed at 25C, after 10 minutes 5,490 6,100 6,710 RPM air flow at 0 inch H O, see performance curves 16.07 CFM 2 static pressure at 0 CFM, see performance curves 0.20 inch H O 2 at 1 m noise 5 Vdc input models 36.0 37.2 dBA 12 Vdc input models 36.0 37.0 dBA 1 PROTECTIONS / SIGNALS parameter conditions/description min typ max units auto restart protection available on all models tachometer signal available on 20 and 22 models PWM control signal available on 22 models Notes: 1. See application notes for details. SAFETY & COMPLIANCE parameter conditions/description min typ max units insulation resistance of frame at 500 Vdc between frame and positive terminal 10 M at 500 Vac, 60 Hz, 1 minute between frame and dielectric strength 5 mA positive terminal safety approvals UL/cUL 507, TUV (EN 62368-1) EN 55022:2010+AC:2011 Class B, EN 61000-3- EMI/EMC 2:2014, EN 61000-3-3:2013, EN 55024:2010 life expectancy at 45C, 15~65% RH 70,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 C storage temperature -40 70 C operating humidity non-condensing 5 90 % storage humidity non-condensing 5 95 % cuidevices.com