Additional Resources: Product Page 3D Model date 02/10/2020 page 1 of 9 SERIES: CFM-50V DESCRIPTION: DC AXIAL FAN FEATURES TM omniCOOL bearing system 50 x 50 mm frame multiple speed options for different cooling needs tachometer signal and rotation detect options available auto restart protection standard on all models 4 input input input rated air static noise MODEL 1 1 1 2 3 voltage current power speed flow pressure rated range max max typ max (Vdc) (Vdc) (mA) (W) (RPM15%) (CFM) (inch H O) (dBA) 2 CFM-5010V-043-260 5 3.5~6 98 0.49 4800 11.0 0.11 25.6 CFM-5010V-052-300 5 3.5~6 179 0.90 5800 13.8 0.15 30.7 CFM-5010V-143-260 12 6~13.8 58 0.70 4800 11.0 0.11 25.6 CFM-5010V-155-310 12 4.5~13.8 81 0.98 5800 13.8 0.15 30.7 CFM-5015V-132-154 12 4.5~13.8 33 0.40 3200 7.7 0.07 15.4 CFM-5015V-138-201 12 4.5~13.8 37 0.48 3800 10.2 0.12 20.1 CFM-5015V-150-290 12 4.5~13.8 54 0.65 5000 13.0 0.17 29.0 CFM-5015V-161-330 12 4.5~13.8 76 0.92 6100 17.0 0.23 33.0 CFM-5015V-172-381 12 4.5~13.8 127 1.53 7200 18.6 0.31 38.1 CFM-5015V-247-290 24 8~27.6 34 0.82 5000 13.0 0.17 29.0 CFM-5015V-258-330 24 8~27.6 51 1.23 6100 17.0 0.23 33.0 Notes: 1. At rated voltage, 25C, 0 inch H 0 static pressure, after 10 minutes 2 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H 0 static pressure 2 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. All specifications are measured at 25C, 65% relativ e humidity unless otherwise specified. PART NUMBER KEY CFM-5010V-043-260 - XX - CXX Fan Signals Base Number Reserved for Custom blank = no signals Configurations 11 = rotation detector signal 20 = tachometer signal cuidevices.comAdditional Resources: Product Page 3D Model CUI Devices SERIES: CFM-50V DESCRIPTION: DC AXIAL FAN date 02/10/2020 page 2 of 9 INPUT parameter conditions/description min typ max units 5 Vdc input models 3.5 5 6 Vdc 1 operating input voltage 12 Vdc input models 4.5 12 13.8 Vdc 24 Vdc input models 8 24 27.6 Vdc 5 Vdc input models 3.5 Vdc 2 starting voltage 12 Vdc input models 4.5 Vdc 24 Vdc input models 8 Vdc Note: 1. See Model section on page 1 for specific input voltage ranges. 2. Starting voltage for model CFM-5010V-143-260 is 6 Vdc. 3 PERFORMANCE parameter conditions/description min typ max units rated speed at rated voltage, 25C, after 10 minutes 3200 7200 RPM air flow at 0 inch H O, see performance curves 7.7 18.6 CFM 2 static pressure at 0 CFM, see performance curves 0.07 0.31 inch H O 2 noise at 1 m 15.4 38.1 dBA Note: 3. See Model section on page 1 for specific values. 4 PROTECTIONS / FEATURES parameter conditions/description min typ max units auto restart on all models rotation detector signal available on 11 models tachometer signal available on 20 models Notes: 4. See Application Notes for details. SAFETY & COMPLIANCE parameter conditions/description min typ max units at 500 Vdc between internal stator and positive insulation resistance of frame 10 M lead wire apply 500 Vac for 1 minute between housing and dielectric strength positive lead wire safety approvals UL/cUL 507, TUV (EN 60950-1) EMI/EMC EN 61000-6-1:2007, EN 61000-6-3:2007+A1 life expectancy at 40C, 65% RH 70,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 C storage temperature -40 70 C cuidevices.com