Additional Resources: Product Page 3D Model date 05/12/2021 page 1 of 6 SERIES: CFM-60S DESCRIPTION: DC AXIAL FAN FEATURES sleeve bearing 60 x 60 mm frame multiple speed options tachometer signal available auto restart 2 4 input input input rated airflow static noise MODEL 1 1 1 3 voltage current power speed pressure rated range max max typ typ (Vdc) (Vdc) (A) (W) (RPM600) (CFM) (inch H O) (dBA) 2 CFM-6020S-030-257 5 4.5~5.5 0.14 0.70 3,000 11.43 0.06 25.7 CFM-6020S-040-320 5 4.5~5.5 0.41 2.05 4,000 15.24 0.12 32.0 CFM-6020S-130-257 12 10.8~13.2 0.08 0.96 3,000 11.43 0.06 25.7 CFM-6020S-150-368 12 10.8~13.2 0.21 2.52 5,000 19.05 0.18 36.8 Notes: 1. At rated voltage, after 3 minutes. 2. At rated voltage, room temperature, 65% humidity, 0 inch H 0 static pressure. 2 3. At rated voltage, 0 CFM airflow. 4. Measured in an anechoic chamber as per ISO3745/GB4214-84 at rated voltage, with background noise 202 dBA at 1 m from the fan intake. 5. All specifications are measured at 25C, 65% relativ e humidity unless otherwise specified. PART NUMBER KEY CFM-6020S-030-257 - XX - CXX Fan Signals Base Number Reserved for Custom blank = no signals Configurations 20 = tachometer signal cuidevices.comAdditional Resources: Product Page 3D Model CUI Devices SERIES: CFM-60S DESCRIPTION: DC AXIAL FAN date 05/12/2021 page 2 of 6 INPUT parameter conditions/description min typ max units 5 Vdc input models 4.5 5 5.5 Vdc 6 operating input voltage 12 Vdc input models 10.8 12 13.2 Vdc 5 Vdc input models 3.5 Vdc starting voltage 12 Vdc input models 7.0 Vdc Note: 6. See Model section on page 1 for specific input voltage ranges. 7 PERFORMANCE parameter conditions/description min typ max units rated speed at rated voltage, 25C, after 3 minutes 3,000 5,000 RPM air flow at 0 inch H O, see performance curves 11.43 19.05 CFM 2 static pressure at 0 CFM, see performance curves 0.06 0.18 inch H O 2 noise at 1 m, rated speed 25.7 36.8 dBA Note: 7. See Model section on page 1 for specific values. 8 PROTECTIONS / FEATURES parameter conditions/description min typ max units auto restart on all models on all models polarity protection tachometer signal available on 20 models Notes: 8. See Application Notes for details. SAFETY & COMPLIANCE parameter conditions/description min typ max units insulation resistance at 500 Vdc between frame and positive terminal 10 M at 500 Vac, 60 Hz, 1 minute between housing and dielectric strength 5 mA positive terminal safety approvals UL/cUL 507, TUV (EN/IEC 62368-1:2020+A11) EMI/EMC EN 55032:2015, EN 55035:2017 life expectancy at 25C, 65% RH, 90% confidence level 30,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 C storage temperature -40 75 C operating humidity non-condensing 35 85 % storage humidity non-condensing 35 85 % cuidevices.com