Additional Resources: Product Page 3D Model date 02/12/2020 page 1 of 9 SERIES: CFM-70V DESCRIPTION: DC AXIAL FAN FEATURES TM omniCOOL bearing system 70 x 70 mm frame multiple speed options for different cooling needs tachometer signal and rotation detect options available auto restart protection standard on all models 4 input input input rated air static noise MODEL 1 1 1 2 3 voltage current power speed flow pressure rated range max max typ max (Vdc) (Vdc) (mA) (W) (RPM15%) (CFM) (inch H O) (dBA) 2 CFM-7015V-123-215 12 6.0~13.8 55 0.66 2300 19.0 0.07 21.5 CFM-7015V-128-265 12 4.5~13.8 86 1.04 2800 23.0 0.09 26.5 CFM-7015V-133-315 12 4.5~13.8 130 1.56 3300 27.0 0.11 31.5 5 CFM-7020V-126-260 12 4.5~13.8 89 1.07 2600 23.5 0.09 26.0 5 CFM-7020V-129-300 12 4.5~13.8 114 1.37 2900 27.0 0.12 30.0 5 CFM-7020V-132-330 12 4.5~13.8 150 1.80 3200 29.0 0.14 33.0 CFM-7020V-140-375 12 6.0~13.8 225 2.70 4000 37.0 0.21 37.5 CFM-7020V-143-400 12 6.0~13.8 265 3.18 4300 40.0 0.24 40.0 CFM-7020V-146-415 12 6.0~12.6 328 3.94 4600 43.0 0.28 41.5 5 CFM-7020V-226-360 24 8.0~27.6 51 1.23 2600 23.5 0.09 26.0 5 CFM-7020V-229-300 24 8.0~27.6 64 1.54 2900 27.0 0.12 30.0 5 CFM-7020V-232-330 24 8.0~27.6 76 1.83 3200 29.0 0.14 33.0 Notes: 1. At rated voltage, 25C, 0 inch H 0 static pressure, after 10 minutes 2 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H 0 static pressure 2 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. Typical rated speed is measured as RPM10% at rated voltage. 6. All specifications are measured at 25C, 65% relativ e humidity unless otherwise specified. PART NUMBER KEY CFM-7015V-123-215 - XX - CXX Fan Signals Base Number Reserved for Custom blank = no signals Configurations 11 = rotation detector signal 20 = tachometer signal cuidevices.comAdditional Resources: Product Page 3D Model CUI Devices SERIES: CFM-70V DESCRIPTION: DC AXIAL FAN date 02/12/2020 page 2 of 9 INPUT parameter conditions/description min typ max units 12 Vdc input models 4.5 12 13.8 Vdc 1 operating input voltage 24 Vdc input models 8 24 27.6 Vdc 12 Vdc input models 4.5 Vdc 2 starting voltage 24 Vdc input models 8 Vdc Note: 1. See Model section on page 1 for specific input voltage ranges. 2. Starting voltage for models CFM-7015V-123-215, CFM-7020V-140-375, CFM-7020V-143-400 and CFM-7020V-146-415 is 6 Vdc. 3 PERFORMANCE parameter conditions/description min typ max units rated speed at rated voltage, 25C, after 10 minutes 2300 4600 RPM air flow at 0 inch H O, see performance curves 19.0 43.0 CFM 2 static pressure at 0 CFM, see performance curves 0.07 0.28 inch H O 2 noise at 1 m 21.5 41.5 dBA Note: 3. See Model section on page 1 for specific values. 4 PROTECTIONS / FEATURES parameter conditions/description min typ max units auto restart on all models rotation detector signal available on 11 models tachometer signal available on 20 models Notes: 4. See Application Notes for details. SAFETY & COMPLIANCE parameter conditions/description min typ max units at 500 Vdc between internal stator and positive insulation resistance of frame 10 M lead wire apply 500 Vac for 1 minute between housing and dielectric strength positive lead wire safety approvals UL/cUL 507, TUV (EN 60950-1) EMI/EMC EN 61000-6-1:2007, EN 61000-6-3:2007+A1 life expectancy at 40C, 65% RH 70,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 C storage temperature -40 70 C cuidevices.com