Additional Resources: Product Page date 02/10/2020 page 1 of 5 SERIES: CFM-92 DESCRIPTION: DC AXIAL FAN FEATURES 92 x 92 mm frame high fan speed for greater air flow dual ball bearing construction auto restart protection standard on all models input input input rated air static noise MODEL 1 2 voltage current power speed flow pressure rated range typ max max typ max (Vdc) (Vdc) (A) (A) (W) (RPM) (CFM) (inch H O) (dBA) 2 CFM-9225-13* 12 6~13.8 0.40 0.5 6 4,200 96.06 0.37 49.8 CFM-9225-23* 24 16~26.4 0.24 0.32 6.72 4,200 96.06 0.37 49.8 Notes: 1. At 0 inch H 0 static pressure. 2 2. At 0 CFM airflow. *. Discontinued CFM-9225-13-11, CFM-9225-23-10, CFM-9225-23-11, CFM-9225-23-20, and CFM-9225-23-22 models. PART NUMBER KEY CFM-9225 - X 3 - XX - CXX Base Number Reserved for Custom Configurations Input Voltage 1 = 12 Vdc Fan Signals 2 = 24 Vdc 10 = no signals 11 = rotation detector signal 20 = tachometer signal 22 = tachometer signal / PWM control signal cuidevices.com DISCONTINUEDAdditional Resources: Product Page CUI Devices SERIES: CFM-92 DESCRIPTION: DC AXIAL FAN date 02/10/2020 page 2 of 5 INPUT parameter conditions/description min typ max units 12 Vdc input models 6 12 13.8 Vdc operating input voltage 24 Vdc input models 16 24 26.4 Vdc 12 Vdc input models 0.40 0.5 A current 24 Vdc input models 0.24 0.32 A 12 Vdc input models 4.80 6 W power 24 Vdc input models 5.76 6.72 W at 25C starting voltage 12 Vdc input models 6 Vdc 24 Vdc input models 16 Vdc PERFORMANCE parameter conditions/description min typ max units rated speed at 25C, after 10 minutes 3,780 4,200 4,620 RPM air flow at 0 inch H O, see performance curves 96.06 CFM 2 static pressure at 0 CFM, see performance curves 0.37 inch H O 2 noise at 1 m 48.5 49.8 dBA 1 PROTECTIONS / SIGNALS parameter conditions/description min typ max units auto restart protection available on all models rotation detector available on 11 models tachometer signal available on 20 and 22 models PWM control signal available on 22 models Notes: 1. See application notes for details. SAFETY & COMPLIANCE parameter conditions/description min typ max units insulation resistance of frame at 500 Vdc between frame and positive terminal 10 M at 500 Vac, 60 Hz, 1 minute between frame and dielectric strength 5 mA positive terminal safety approvals UL/cUL 507, TUV (EN 62368-1) EN 55022:2010+AC:2011 Class B, EN 61000-3- EMI/EMC 2:2014, EN 61000-3-3:2013, EN 55024:2010 life expectancy at 45C, 15~65% RH 70,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -10 70 C storage temperature -40 70 C operating humidity non-condensing 5 90 % storage humidity non-condensing 5 95 % cuidevices.com DISCONTINUED