Additional Resources: Product Page 3D Model PCB Footprint date 10/12/2020 page 1 of 10 SERIES: PBO-5 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 5 W continuous power ultra-compact SIP package wide input voltage range over current and short circuit protections 4,000 Vac isolation IEC, EN, UL62368 safety approvals efficiency up to 79% 2 output output output ripple efficiency MODEL 1 voltage current power and noise min max max max typ (Vdc) (mA) (mA) (W) (mVp-p) (%) PBO-5-S3.3 3.3 0 1000 3.3 150 67 PBO-5-S5 5 0 1000 5 150 74 PBO-5-S9 9 0 560 5 150 75 PBO-5-S12 12 0 420 5 150 76 PBO-5-S15 15 0 340 5 150 77 PBO-5-S24 24 0 210 5 150 79 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with a 1 F ceramic and 10 F electrolytyic capacitor on the output. 2. At 230 Vac input. 3. All specifications are measured at Ta=25C, humidity <75%, 115 or 230 Vac input voltage, and rated output load unless otherwise specified. PART NUMBER KEY PBO-5 - S XX - X Base Number Output Voltage Orientation: blank = vertical B = right-angle cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: PBO-5 DESCRIPTION: AC-DC POWER SUPPLY date 10/12/2020 page 2 of 10 INPUT parameter conditions/description min typ max units 85 305 Vac voltage 100 430 Vdc frequency 47 63 Hz at 115 Vac 0.2 A current at 230 Vac 0.1 A at 115 Vac 5 A inrush current at 230 Vac 10 A leakage current CY0 is 1 nF/400 Vac 0.25 mA no load power consumption 0.5 W OUTPUT parameter conditions/description min typ max units 3.3 Vdc output models 2,200 F 5 Vdc output models 1,500 F 9 Vdc output models 680 F capacitive load 12 Vdc output models 470 F 15 Vdc output models 330 F 24 Vdc output models 100 F 3.3 Vdc output models 3 % initial set point accuracy all other models 2 % line regulation at full load 0.5 % load regulation from 10~100% load 1.5 % at 115 Vac 15 ms hold-up time at 230 Vac 75 ms switching frequency 100 kHz temperature coefficient 0.02 %/C PROTECTIONS parameter conditions/description min typ max units output voltage clamp 3.3 & 5 Vdc output models 7.5 Vdc over voltage protection 9 Vdc output models 15 Vdc 12 & 15 Vdc output models 20 Vdc 24 Vdc output models 30 Vdc over current protection auto recovery 150 % short circuit protection continuous, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output at 5 mA for 1 minute 4,000 Vac safety approvals certified to 62368: IEC, EN, UL safety class class II CISPR32/EN55032 Class A, (recommended circuit 1,4) conducted emissions CISPR32/EN55032 Class B, (recommended circuit 2,3) radiated emissions CISPR32/EN55032 Class B, (recommended circuit 1,2,3,4) ESD IEC/EN61000-4-2, 6 kV, perf. Criteria B radiated immunity IEC/EN61000-4-3, 10V/m, perf. Criteria A IEC/EN61000-4-4, 2 kV (recommended circuit 1,2), perf. Criteria B EF T/burst IEC/EN61000-4-4, 4 kV (recommended circuit 3,4), perf. Criteria B cui.com