50 x 50 mm COMPACT SENSORS New background and foreground suppression models Free voltage versions with relay output 10-30 Vdc version with transistor output Standard cable or M12 connection S6 SERIES The S6 series, thanks to the excellent detection performances and the variety of power supply and connection possibilities, offers the most complete universal sensor range in the compact 50x50 mm housing. The operating distance can be set to the optimal value in each model: 2 m diffuse proximity, 25 or 50 cm background suppression, 5 m polarised retroreflex, 1 m retroreflex versions for transparent objects and 20 m through beam. New proximity models with 5 to 20 cm foreground suppression and 12 to 110 cm background suppression are available. The free voltage versions have a relay output and cable connection. The versions with 10-30 Vdc power supply present cable connection and NPN/PNP output or M12 connector, with either PNP output with dark/light configuration and NPN or PNP double NO-NC output complying to the EN 60947-5-2 standard. UNIVERSAL MIDI SENSORSTECHNICAL DATA DETECTION DIAGRAMS Power supply: ............................................... 10 ... 30 Vdc (d.c. vers.), reverse polarity Grey R18% White R90% protection 15 ... 264 Vac (free voltage vers.) Consumption: ............................................... 30 mA max. (d.c. vers.) 40 mA max. (free voltage vers.) Light emission: ............................................. infrared LED 880 nm red LED 660 nm (B3, T1, M10 vers.) S6-x-C90-x Diffuse proximity operating distance: ........ 1 ... 90 cm (C90 vers.) 5 ... 200 cm (C200 vers.) White R90% Grey R18% Background suppression op. distance: ..... 10 ... 50 cm (M50 vers.) 3 ... 25 cm (M25 vers.), 10 cm (M10 vers.) Foreground suppression op. distance: ...... 5 ... 20 cm (Backgr. suppr.: 12 ... 110 cm) Retroreflex operating distance: .................. 0.1 ... 6 m (on R2) Polarised retroreflex operating distance: .. 0.1 ... 5 m (on R2) S6-x-C200-x Retroreflex transparents op. distance: ...... 0.1 ... 1 m (on R2) Through beam operating distance: ............ 0 ... 20 m Grey R18% White R90% Setting: .......................................................... sensitivity trimmer (G vers. excluded) distance adj. screw (M25, M50, N20 vers.) Indicators: ..................................................... red OUTPUT LED green STABILITY LED (M, N vers.) red POWER LED (G5 vers.) Output type: .................................................. NPN/PNP configurable (d.c. vers.) S6-x-M10-x PNP (S6T vers.) NPN or PNP NO-NC (S6R vers.) Grey R18% White R90% relay SPDT 250V/3A (free voltage vers.) Saturation tension: .......................................1.5 V max. (d.c. vers.) Output current: ............................................. 100 mA max., short-circuit protection 3 A max. resistive load (free voltage vers.) Response time: .............................................1 ms max. (d.c. vers.), 2 ms max. (F vers.) S6-x-M25-x 30 ms max. (free voltage vers.) Switching frequency: ................................... 500 Hz max., 250 Hz max.(F/G vers. in d.c.) Grey R18% White R90% 16 Hz max. (free voltage vers.) Operating mode: ...........................................dark/light configurable Auxiliary functions: ...................................... test + and test - inputs (G vers. in d.c.) Connection: ...................................................4-pole M12 connector (S6T/S6R vers.) 2 m 6 mm cable (S6 vers.) Electrical protection: ....................................class 1 (free voltage vers.) S6-x-M50-x class 2 (d.c. vers.) Mechanical protection: ................................ IP65 Housing material: ......................................... ABS Lens material: ............................................... PMMA plastic Weight: .......................................................... 40 g max. (connector vers.) detection area 160 g max. (cable vers.) Operating temperature: ................................-25 ... +55C foreground suppr. Storage temperature: ................................... -25 ... +70C S6-x-N20-x Reference standard: ..................................... EN 60947-5-2 Certifications: ............................................... ( d.c.vers.) The detection diagrams indicate the typical The operating distances indicate the detection distance with excess gain 2. operating distance with excess gain 1. UNI EN ISO9001 UNI EN ISO14000 background suppr.