Revolutionary magnetic interconnect technology Creates magnetic connection between wristband and coil cord meets ANSI/ESD S20.20 and ESD S1.1, including disengagement force test (1-5 lbs). More consistent disengagement force than standard 4 mm designs. Dual-wire wrist strap provides redundancy If one dual wire wrist strap condutor is severed, operator still has reliable path-to-ground with other wire 3.5 mm mono plug compatible with 3M and other brand Continuous Monitors More reliable design MagSnap revolutionary design provides consistent retention and release performance. 19829 Premium metal expansion wrist strap Comfortable, designed not to pinch or pull hair Durable metal band Long wearing, easy to clean Superior contact with skin Magnetic For reliable removal of generated static charges Sockets Non-flaking or scratching laminated insulator on all external surfaces Protects wearers from electrical hazards provides many years of product life UL Listed 3.5 mm Note: This product is not recommended for use on equipment with operating voltage exceeding 250 VAC. Mono Plug CAUTION: The ESD Series is for electrostatic control. It will not reduce or increase your risk of receiving electric shock when using or working on electrical equipment. Follow the same precautions you would use Jewel MagSnap Wrist Straps meet or exceed the requirements of ANSI/ESD S20.20 and without wrist straps, including: ANSI/ESD S1.1 including section 5.4 Breakaway Force With the ground cord connected to Make certain that equipment having a grounding type plug is properly grounded. the cuff in a normal manner, a force of .45 kg (1 lb) but 2.3 kg (5 lb) applied to the ground Make certain that you are not in contact with grounded objects other than through the ESD Series. cord, in the normal disconnect direction, shall be required to separate the ground cord from Superior resistor connection strain relief the cuff. Superior reliability. Greatly exceeds ESD S1.1 Bending Life Test. Tested at over 11 million cycles vs. the Per ANSI/ESD S20.20 Paragraph 6.2.2.1. Personnel Grounding Requirements All personnel 16,000 requirement shall be bonded or electrically connected to ground or contrived ground when handling ESD Covered by one or more of the following patents: sensitive items. When personnel are seated at ESD protective workstations, they shall be Wristband: 4,639,825 connected to the common point ground via a wrist strap system. Superior warranty - See details of 1 year Limited Warranty at At first glance, the ground cord appears to be a relatively simple assembly. However, the www.Desco.com/LimitedJewelWarranty.aspx design requirements are considerable, given the wide range of user applications and the Made in America durability requirements of constant tugging, flexing, and dragging over the edge of workstation tops and equipment chassis. (ESD Handbook TR20.20 paragraph 5.3.2.2.2 Wrist Strap Ground Cord) Item Description NOTE: Complete wrist strap kits include an alligator clip. Wrist strap kits include an alligator clip for occasions when a grounded banana jack is not available. However, Wrist strap 19826 Jewel MagSnap Dual-Wire Metal Wristband, Large ground cords must be connected to a groundable point or an equipotential bonding point. Do 19827 Jewel MagSnap Dual-Wire Metal Wristband, Medium not connect to a snap on a dissipative mat unless it is the groundable point for the mat. Do not clip a wirst strap to the edge of a dissipative mat. (ESD Handbook TR20.20 section 5.3.2.7) 19828 Jewel MagSnap Dual-Wire Metal Wristband, Small ESD Handbook TR 20.20 paragraph 5.3.2.4.4 Test Frequency Because wrist straps have a 19829 Jewel MagSnap Dual-Wire Metal Wrist Strap, Large, 6 ft Coil Cord finite life, it is important to develop a test frequency that will guarantee integrity of the system. Typical test programs recommend that wrist straps that are used daily should be tested daily. 19830 Jewel MagSnap Dual-Wire Metal Wrist Strap, Medium, 6 ft Coil Cord However, if the products that are being produced are of such value that knowledge of a 19831 Jewel MagSnap Dual-Wire Metal Wrist Strap, Small, 6 ft Coil Cord continuous, reliable ground is needed, and then continuous monitoring should be considered or even required 19832 Jewel MagSnap Dual-Wire Metal Wrist Strap, Large, 12 ft Coil Cord Continuous Monitors pay for themselves improving quality, productivity, eliminating wrist strap 19833 Jewel MagSnap Dual-Wire Metal Wrist Strap, Medium, 12 ft Coil Cord daily testing and test result logging. Per ESD-S1.1 paragraph 6.1.3 Frequency of Functional 19834 Jewel MagSnap Dual-Wire Metal Wrist Strap, Small, 12 ft Coil Cord Testing Daily (Wrist Strap) testing may be omitted if constant monitoring is used. Made in America Improve wrist strap contact with Reztore ESD Hand Lotion. See Drawing 19820 for details on Jewel MagSnap Dual-Wire Coil Cords Jewel MagSnap Dual-Wire Metal Wrist Strap DESCO WEST: 3651 WALNUT AVE., CHINO, CA 91710 WEB SITE: Desco.com DRAWING DATE: PHONE (909) 627-8178 NUMBER March DESCO EAST: ONE COLGATE WAY, CANTON, MA 02021-1407 PHONE (781) 821-8370 19826 2009 2009 DESCO INDUSTRIES INC. Employee OwnedX-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Antistatic Control Products category: Click to view products by Desco manufacturer: Other Similar products are found below : 13505 13870 14404 20-053-0017 2229 2231 3039 37061 39792 42470 XON-ASB4X30 XON-ASB4X6 XON-ASB6X30 09813 09857 XON-ASB8X10 XON-ASB6X10 19695 09037 68101 68103 73741 13515 13869 13868 13485 13457 13245 13332 13205 13135 91070 8031 8523 13080 13215 157 ROLL BEIGE 1.0 VERAX1R-300R 17260 66051 12550 19863 09121 73831 13340 13338 04541 19696 16104 SPI-20686