USER GUIDE TB-9072 Electronic Service Vacuum Made in the Operation and Maintenance United States of America 497ABG Electronic Service Vacuum, 220 VAC, Euro Plug: SV-MPF2 Type 2 Filter 8 Foot Power Cord, Europe SV-SH33 7 Foot Dissipative Hose SV-WA2 Wand SV-CN1 Crevice Tool SV-CB1 Crevice Tool Brush SV-DBSD1 Dust Brush SV-NN Needle Nose Nozzle 497ABG-NO Electronic Service Vacuum, 220 VAC, No Power Cord: Figure 1. Electronic Service Vacuum. SV-MPF2 Type 2 Filter SV-SH33 7 Foot Dissipative Hose Description SV-WA2 Wand The 497AJN/497ABG Electronic Service Vacuum is SV-CN1 Crevice Tool designed for high-efficiency cleanup of most business SV-CB1 Crevice Tool Brush equipment including removing toner and dust. Portability, SV-DBSD1 Dust Brush quick setup and efficient and safe operation are key SV-NN Needle Nose Nozzle features of this vacuum. It contains a one horsepower, six amp motor. Grounding Instructions The 497AJN Vacuum is for use on a nominal 120 volt This product meets ANSI/ESD S20.20 and is designed circuit and has a grounding plug. The 497ABG Vacuum to be used in an ESD protected area The hose and is for use on a nominal 240 volt circuit and has a accessories are conductive/dissipative so electrostatic grounding plug. Make sure the vacuum is connected to charges will be removed when properly grounded an outlet having the same configuration as the plug. No through the power cord to electrical outlet ground prong. adapter should be used with this vacuum. Any service on the vacuum should be performed by an authorized The SCS Electronic Service Vacuum is available in three service representative. models: Warning: Improper connection of the equipment- grounding conductor can result in the risk of electric Item Description shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is 497AJN Electronic Service Vacuum, 120 VAC, properly grounded. Do not modify the plug provided with US Plug the appliance. If the plug does not fit the outlet, have a proper outlet installed by a qualified electrician. 497ABG Electronic Service Vacuum, 220 VAC, Euro Plug Specifications 497ABG-NO Electronic Service Vacuum, 220 VAC, Electrical No Power Cord 497AJN 120VAC, 50/60Hz, 6.0amps 497ABG 220/240VAC, 50/60Hz, 4.25amps 497ABG-NO 220/240VAC, 50/60Hz, 4.25amps Packaging Motor 1 Horsepower Suction Approx. 51/H20 497AJN Electronic Service Vacuum, 120 VAC, US Plug: Dimensions 17.8 L x 7.8 W x 9.3 H SV-MPF2 Type 2 Filter (45.2 cm L x 19.7 cm W x 23.5 cm H) SV-PC8 8 Foot Power Cord SV-SH33 7 Foot Dissipative Hose Weight 11 lbs. SV-WA2 Wand Certification cULus, EAC SV-CN1 Crevice Tool SV-CB1 Crevice Tool Brush SV-DBSD1 Dust Brush SV-NN Needle Nose Nozzle SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 West: (909) 627-9634 Website: StaticControl.com 2018 DESCO INDUSTRIES INC TB-9072 Page 1 of 3 March 2018 Employee OwnedTo Operate 1. Release latches and open lid . 2. Unfasten accessory door and remove vacuum hose, electrical cord and hose attachments . 3. Remove filter plug from vacuum inlet (always replace when repacking for transport) . 4. Attach selected accessory to hose (insert crevice brush as shown ). Insert other end of hose into inlet . 5. Place remaining accessory and filter plug in lid. Close lid. 6. Latch lid securely. 7. Insert hooded end of power cord in power cord receptacle on vacuum . Figure 3. How to replace the Electronic Service Vacuum 8. Plug cord into power outlet. Filter. 9. Turn on power switch . 1. Release the latches and open the lid . 2. Remove red filter plug or hose. Save the plug for use later (see WEEE Statement). 3. Grasp the filter on each side by using the circular indentations . Pull filter straight up by both ends. 4. Insert the red filter plug in the filter. 5. Dispose of the filter in a suitable manner. 6. Remove the red plug from the new filter and position filter in the vacuum with the filter hole to your left. Save the red plug for use in disposing of the filter (see WEEE Statement). 7. Verify that the gasket between the filter and the motor fits tightly. 8. Insert the red filter plug or hose. 9. Close and latch the lid. To Store Attachments for Transport 1. Unplug the power cord from the outlet and vacuum . 2. Open the lid and retrieve the filter plug. 3. Remove the hose from the inlet and insert the filter plug. 4. Detach the hose nozzle from the base. Figure 2. How to operate the Electronic Service Vacuum. 5. Place the hose, power cord and attachments into the lid and close the accessory door. To Replace Filter 6. Close the lid and securely fasten the latches . The Electronic Service Vacuum is designed for use with disposable SCS Filters. The filters must be replaced on Safety Information a regular basis. Frequency of filter replacement depends Warning: TO REDUCE THE RISK OF FIRE, ELECTRIC on the type and frequency of use of the Electronic SHOCK OR INJURY, FOLLOW THESE SAFETY Service Vacuum. RULES: 1. Use only as described in this manual. Use only manufacturers recommended attachments. 2. Do not use this machine to vacuum hazardous dust, flammable or combustible liquids, such as gasoline. 3. Connect to a properly grounded outlet only. See Grounding instructions. 4. Do not use without filter in place. 5. Do not leave appliance plugged in when not in use. Unplug from the outlet when not in use and before servicing. 6. Turn off all controls before unplugging SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 West: (909) 627-9634 Website: StaticControl.com 2018 DESCO INDUSTRIES INC TB-9072 Page 2 of 3 Employee Owned