USER GUIDE TB-9043 9110 Benchtop Air Ionizer Installation, Operation and Maintenance Features and Components Grill Tabs Front Grill Knobs Tab Screws Fan Speed Control Power Switch LED Power Indicator Saftey Switch Figure 2. Benchtop Air Ionizer features and components (front view) Figure 1. SCS 9110 Benchtop Air Ionizer Description The SCS 9110 Benchtop Air Ionizers a self-contained, ionized air blower designed to neutralize electrostatic charges from non-conductive objects (insulators) and isolated conductors. The SCS 9110 meets ANSI/ESD Back Grill S20.20 tested per ANSI/ESD STM3.1 and ESD TR53. The ionizer is designed with a built-in automatic emitter points cleaner to periodically clean the emitter points Offset Voltage Adjust therefore saving some manual work and time. The SCS 9110 Benchtop Air Ionizer is available in one Fuse Holder model: DC Input Jack Ground Terminal Item Power Adapter Input Figure 3. Benchtop Air Ionizer features and components 9110-NO 100-240 VAC (rear view) The SCS 9110 Benchtop Air Ionizer does not include a power cord. It must be purchased separately. Item Description 770000 Power Cord, IEC C-13, North America 770001 Power Cord, IEC C-13, UK 770002 Power Cord, IEC C-13, Europe 770003 Power Cord, IEC C-13, China Packaging 1 Benchtop Air Ionizer Unit Figure 4. Power adapter (included) and SCS 770000 1 Power Adapter, 100-240VAC Input, No Power Cord North America Power Cord (not included) 1 Ground Wire 1 Certificate of Calibration SCS - 926 JR Industrial Drive, Sanford, NC 27332 (919) 718-0000 Website: StaticControl.com 2015 DESCO INDUSTRIES, INC. TB-9043 Page 1 of 5 August 2015 Employee OwnedInstallation Maintenance The Benchtop Air Ionizer mounts easily in a variety of 1. When performing emitter points maintenance, positions using the provided tilting bracket/stand. Mount disconnect the Power Adapter AC plug from the the bracket by following the illustration below. Secure outlet. Do not connect or disconnect the power the mounting bracket with screws on table top. Adjust plug with wet hands as doing so puts you at risk of the angle of air flow towards the target and secure it by electrical shock or injury. tightening the side knobs. 2. Occasional cleaning of the case is the only routine maintenance required. Although the emitter points Metal screw Metal screw 4mm 4 x 20x m20mmm have a built-in automatic cleaner, a check is still necessary for any abnormality within the emitter points. Verification and adjustment may be required to keep the balance within the specification range. 3. Cleaning the Case - Wipe the case with a moistened, fully squeezed soft cloth with deionized water. If a stronger cleaning solution is required, use a soft cloth with a mixture of alcohol and water (70% IPA and 30% DI water). Do not use any other 1. Remove both side 2. Mount the bracket 3. Replace the fan body. Tighten solvents that can damage the coating of the case. 1. Remove both side knobs one 2. Mount the bracket using 3. Replace the fan body. Tighten knobs one at a time. using three screws. both knobs to a desired air flow at a time. three screws. both knobs to a desired air ow Fully squeeze the cloth or sponge to remove any angle abgltowards e towardsthe the ttarget arget oof f ionization. ionization. excess liquid. Figure 5. Installing the Benchtop Air Ionizer 4. Cleaning the Emitter Points - The emitter points and auto-cleaning brushes are accessible through the The safety of any system incorporating this equipment front grill. To clean them, turn off the unit clean the is the responsibility of the assembler of the system. The points and brushes with a cotton swab. Use caution ionizers performance is affected by its distance from when accessing the emitter points to avoid injury. the worksurface and fan speed. As distance increases Access to the points is available by removing two or fan speed is reduced, the discharge time at the work tab screws on each side, pressing the side tabs, surface will increase. and pulling off the grill (see images below). Use caution when removing the grill to avoid breaking WARNING: The Benchtop Air Ionizer is not designed to the cable that connects the grill. Be careful not to be used in explosive areas or flammable atmospheres. bend the emitter points during cleaning. The emitter Sparks from the fan motor or emitter points may cause points are fixed and therefore not replaceable. ignition. 5. The safety switch functions to turn off the power Electrical to the ionizer when the front grill is removed while Use the included AC/DC power adapter. For proper the ionizer is in operation. Before any maintenance operation, the unit must be grounded for safe operation. is performed on the emitter points and before Grounding removing the front grill, ensure the unit is powered The Benchtop Air Ionizer must be connected to ground off and the power cord is removed from the ionizer through the GROUND Terminal behind the unit and or the wall outlet. the ground wire included in the package. Connect the 6. Re-attach the front grill after cleaning the emitter ground wire to a known good electrical ground. Failure points and fan blades. Replace the two tab screws to connect the ground terminal may cause the unit to on each side of the grill. malfunction. 7. Service - If you believe that a unit is not functioning Operation properly, disconnect the unit from power. If the unit is covered by Warranty, contact your SCS sales 1. Insert the AC/DC power adapter plug into an representative or distributor. electrical outlet. Make certain that power line voltage is within the operating range of the AC/DC CAUTION: There are no user replaceable parts. power adapter. The use of improper power line Unauthorized replacement of parts will void the voltages may impair operation or damage the unit. warranty. This will void the warranty. 2. The power switch on the front of the unit turns the power and LED Power Indicator illuminates when its on. The dial knob adjusts the fan speed. Rotating it clockwise increases the fan speed. SCS - 926 JR Industrial Drive, Sanford, NC 27332 (919) 718-0000 Website: StaticControl.com 2015 DESCO INDUSTRIES, INC. TB-9043 Page 2 of 5 Employee Owned