USER GUIDE TB-9008 Mini Air Ionizer Installation, Operation and Maintenance The Mini Air Ionizer requires 24 VAC power supplied through a RJ-11 power socket located on the back of the unit. It is possible to connect four (4) Mini Air Ionizers together in series and power them off of one power supply. Use the included RJ-11 cable to daisy-chain the Mini Air Ionizer to another Mini Air Ionizer. A third or fourth Mini Air Ionizer can be daisy-chained using additional RJ-11 cables. To reduce the risk of electric shock, the power supplies use a grounding plug that has a third (grounding) pin. This plug will only fit into a grounding-type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter the plug in any way. If an alternate power source is used, please make sure that it conforms to the power input requirements as listed in the Specifications section. For further questions concerning the power-input requirements, please contact SCS Customer Service. Packaging Figure 1. SCS 960 Mini Air Ionizer 1 Mini Air Ionizer 1 RJ-11 Cable, 3 ft. Description 1 Certificate of Calibration The SCS Mini Air Ionizer is a self-contained ionizing air blower designed to neutralize static charges from NOTE: Power adapter is not included and must be non-conductive objects. The proprietary circuitry purchased separately. contained in the blower generates balanced levels of positive and negative ions, and maintains correct Installation balance despite variations in line voltage, fan speed, The Mini Air Ionizer mounts easily in a variety of and emitter point condition. Meets ANS/ESD S20.20 positions using the provided tilting bracket/stand. Place tested per ANSI/ESD STM3.1 and ESD TR53. the unit on the worksurface and point it at the area or The Mini Air Ionizer reduces a static charge of 1000 V object to be neutralized. Alternatively, the mounting to 100 V in less than 4 seconds (the discharge time) at bracket may be attached directly to or above the a distance of 1 foot. workstation, or on another supporting structure. Please note that placement of the Mini Air Ionizer is important The power supply for the Mini Air Ionizer is sold in controlling its effectiveness. Its distance from the separately. The Mini Air Ionizer and its accessories are target object will affect the ionizers performance. As available as the following item numbers: distance increases, the discharge time will increase. Item Description Connect the RJ-11 terminal from an SCS power adapter to the back of the Mini Air Ionizer, and connect the 960 Mini Air Ionizer power adapter to an appropriate power outlet. Since the 960X/980X Power Adapter, 120 VAC Input, 24 VAC Mini Air Ionizer does not have a power switch, supplying Output, North America Plug power to the unit automatically turns it on. 770753 Power Adapter, 230 VAC Input, 24 VAC Output, UK Plug Operation 770754 Power Adapter, 230 VAC Input, 24 VAC Supplying power to the Mini Air Ionizer through the Output, Europe Plug power socket in the back of the unit will turn it on. A green monitor light is also illuminated on the front of the unit, which indicates that the ionizer is on, and that power is being applied to the emitter points. SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 West: (909) 627-9634 Website: StaticControl.com 2021 DESCO INDUSTRIES INC TB-9008 Page 1 of 2 December 2021 Employee OwnedSpecifications Input Voltage and AC Power Adapter Frequency Power Input: (120 VAC External 120 VAC, 60 Hz Adapter) Power Output: 24 VAC, 500 mA Input Voltage and AC Power Adapter Frequency Power Input: (230 VAC External 230 VAC, 50 Hz Adapter) Power Output: 24 VAC, 500 mA Operating Temperature 59 to 95 F (15 to 35 C) Figure 2. Using the Mini Air Ionizer inside a pick and Power Consumption 5 W place machine Dimensions 4.5 x 3.3 x 2.0 (including bracket) (114 mm x 84 mm x 51 mm) Maintenance Weight 0.75 lbs (0.3 kg) Occasional cleaning of the case and of the ionizing Balance (Offset 20 V electrodes are the only routine maintenance procedures Voltage) at 12 required. Neutralization < 4 seconds CLEANING THE CASE (Discharge) Time at 12 Wipe the case with a soft cloth moistened with water. Maximum Airflow 24 CFM If a stronger cleaning solution is required, mild soap with water may be used. The use of any other cleaning Ozone <0.05 ppm solutions is not recommended. Certifications cULus CLEANING THE EMITTER POINTS Country of Origin China NOTE: Disconnect the power to the ionizer whenever cleaning the emitter points. When the emitter pionts become dirty, the internal circuitry of the ionizer will be automatically adjusted to emit an equal amount of positive and negative ions. Particulates on the emitter point may, however, inhibit ionization to a limited degree. The emitter points are located between the fan blades and the rear grill. A jet of clean, compressed air can be used to remove dirt on emitter points. If a more rigorous cleaning method is needed to remove particulate, clean the points with a cotton swab dampened with isopropyl alcohol. Access to the points is available through the rear grill. Be careful not to damage the points during cleaning. Figure 3. Pin-out of RJ11 power plug and inlet Limited Warranty, Warranty Exclusions, Limit of Liability and RMA Request Instructions See the SCS Warranty - StaticControl.com/Limited-Warranty.aspx SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 West: (909) 627-9634 Website: StaticControl.com 2021 DESCO INDUSTRIES INC TB-9008 Page 2 of 2 Employee Owned