USER GUIDE TB-9022 Iron Man Plus Workstation Monitor Installation, Operation and Maintenance Made in the United States of America Features and Components A B C D FRONT VIEW Figure 1. Iron Man Plus Workstation Monitor Description E The SCS Iron Man Plus Workstation Monitor: Monitors a voltage level that is being generated on a printed circuit board while working on it. Monitors resistance to ground of a conductive or dissipative static control type of worksurface. F G H I J Monitors resistance and voltage on a dual conductor REAR VIEW wrist strap while being worn by a person. The Iron Man Plus Workstation Monitor is available in Figure 2. Iron Man Plus Worstation Monitor features one model: and components Item Description A. Iron LED: When the LED is illuminated green, the voltage level on the monitored PCB ground plane CTC331-WW Iron Man Plus Workstation Monitor, is below the preset alarm level. When the LED is with World Wide Power Adapter illuminated red and the alarm sounds, the the voltage level on the monitored PCB ground plane is above the SCS offers the following accessories for the Iron Man preset alarm level. Plus Workstation Monitor: B. Mat LED: When the LED is illuminated green, the Item Description worksurface mat is properly grounded. When the LED is CTA212 Power Adapter, 100-240VAC Input, illuminated red and the alarm sounds, the worksurface 12VDC 1.5A Output, All Plugs mat is not properly grounded. CTA251 Replacement Jack PCB, Iron Man C. Operator LED: When the LED is illuminated green, Plus the operator is properly grounded and their voltage level is below the preset alarm level. When the LED is CTE701 Workstation Monitor Checker illuminated solid red and the alarm sounds, the operator is not properly grounded. When the LED is blinking red Packaging and the alarm sounds, the body voltage on the operator above the preset alarm level. 1 Iron Man Plus Workstation Monitor 1 Mat Monitor Cord (White) D. Monitored Operator Jack: The operator connects to 1 PCB Cord with Alligator Clip (Yellow) the monitor here. 1 Monitor Ground Cord (Green and Yellow) 1 Power Adapter, 12VDC, with interchangeable plugs E. Power Jack: Connect the included 12VDC power (North America, UK/Asia, Europe) adapter here. 1 Push and Clinch Snap, 10 mm F. Audible Alarm Switch: Press the switch to enable or 1 Countersunk Washer disable the audible alarm. 1 Flat Head Screw, 6-32 x 1/4 1 Certificate of Calibration SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 West: (909) 627-9634 Website: StaticControl.com 2020 DESCO INDUSTRIES INC. TB-9022 Page 1 of 5 February 2020 Employee OwnedG. Ground Terminal: Common ground point for the Placement monitor. Set the Iron Man Plus Workstation Monitor in a clearly visible, convenient location where it does not interfere H. Monitored Mat Terminal: Monitors a worksurface with normal work. mat for proper dissipative resistance and static charges. Connecting Reference Ground I. Monitored Board Terminal: Monitors the voltage Prepare an 18 AWG wire. Strip off the wire insulation level on a PCB ground plane. approximately 8mm (1/3 in) at each end of the wire. J. Voltage Alarm Adjustment: Turn the trimpot Twist the stranded wire on each end. In order to attach clockwise to increase the voltage alarm threshold. Turn the wire to the Iron Man Plus Workstation Monitor, the trimpot counter-clockwise to decrease the voltage insert a small blade screwdriver into the orange slot alarm threshold. above the reference ground connector. Gently push inward and insert the stripped wire fully into the hole in the green connector. Release the screwdriver to allow Installation the wire to catch. Attach the other end of the reference ground wire to a known-good-ground in the area. Connecting Mat Worksurface Prepare an 18 AWG wire. Strip off the wire insulation approximately 8mm (1/3 in) at each end of the wire. Twist the stranded wire on each end. In order to attach the wire to the Iron Man Plus Workstation Monitor, insert a small blade screwdriver into the orange slot above the Mat connector. Gently push inward and insert the stripped wire fully into the hole in the green connector. Release the screwdriver to allow the wire to catch. Use the suppliers recommended method to connect the mat worksurface to the other end of the wire. Connecting Cable to Board Under Test Attach the provided cable with alligator clip to the back of the Iron Man Plus Workstation Monitor. In order to attach the wire to the Iron Man , insert a small blade screwdriver into the orange slot above the Board connector. Gently push inward and insert the stripped wire fully into the hole in the green connector. Release the screwdriver to allow the wire to catch. Attach the other end of the cable to the targeted PCB using the alligator clip. Connecting Power Plug the power adapter into a power outlet, and plug the cord into the Iron Man Plus Workstation Monitor. Mounting Determine the mounting location of the Iron Man Plus Workstation Monitor. Mount the unit using one of the following recommended methods: Screws Figure 3. Installing the Iron Man Plus Workstation Dual Lock Fastener Monitor SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 West: (909) 627-9634 Website: StaticControl.com 2020 DESCO INDUSTRIES INC. TB-9022 Page 2 of 5 Employee Owned