MBRB1530CT - MBRB1545CT
15A SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
Features and Benefits Mechanical Data
2
Guard Ring Die Construction for Transient Protection Case: D PAK
Low Power Loss, High Efficiency Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
High Surge Capability
Moisture Sensitivity: Level 1 per J-STD-020
High Current Capability and Low Forward Voltage Drop
Terminals: Finish Tin. Solderable per MIL-STD-202, Method
Surge Overload Rating to 150A Peak
208
For Use in Low Voltage, High Frequency Inverters, Free
Polarity: See Diagram
Wheeling, and Polarity Protection Applications
Weight: 1.7 grams (approximate)
Lead Free Finish, RoHS Compliant (Note 1)
PIN 1
PIN 2 & 4
PIN 3
Top View Polarity
Ordering Information (Note 2)
Device Packaging Shipping
2
MBRB1530CT-T D PAK 800/Tape & Reel, 13-inch
2
MBRB1535CT-T D PAK 800/Tape & Reel, 13-inch
2
MBRB1540CT-T D PAK 800/Tape & Reel, 13-inch
2
MBRB1545CT-T D PAK 800/Tape & Reel, 13-inch
Notes: 1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes
2. For packaging details, visit our website at
MBRB1530CT - MBRB1545CT
Maximum Ratings @T = 25C unless otherwise specified
A
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
MBRB MBRB MBRB MBRB
Characteristic Symbol Unit
1530CT 1535CT 1540CT 1545CT
V
Peak Repetitive Reverse Voltage RRM
Working Peak Reverse Voltage V 30 35 40 45 V
RWM
DC Blocking Voltage
V
R
RMS Reverse Voltage 21 24.5 28 31.5 V
V
R(RMS)
Average Rectified Output Current @ T = 105C I 15 A
C O
Non-Repetitive Peak Forward Surge Current 8.3ms
I 150 A
FSM
Single Half Sine-Wave Superimposed on Rated Load
Thermal Characteristics
Characteristic Symbol Value Unit
Typical Thermal Resistance Junction to Terminal 3.0 C/W
R
JT
V 80% V -65 to +150
R RRM
Operating Temperature Range (Note 3) C
V 50% V T 180
R RRM J
DC Forward Mode 200
Storage Temperature Range T -65 to +175 C
STG
Electrical Characteristics @T = 25C unless otherwise specified
A
Characteristic Symbol Value Unit
Forward Voltage, per Element @ I = 7.5A V 0.7 V
F FM
Voltage Rate of Change dv/dt 10,000 V/s
Peak Reverse Current @ T = 25C 0.1
A
I mA
RM
15
at Rated DC Blocking Voltage (Note 4) @ T = 100C
A
Maximum Reverse Recovery Time (Note 5) t 30 ns
rr
Typical Total Capacitance (Note 6) 250 pF
C
T
Notes: 3. The heat generated must be less than the thermal conductivity from Junction-to-Ambient: dP /dT < 1/R
D J JA
4. 300s pulse width, 2% duty cycle.
5. Reverse recovery test conditions: IF = 0.5A, IR = 1.0A, Irr = 0.25A (see figure 1).
6. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC.
20 100
16
10
12
8
1.0
4
T = 25 C
j
0
0.1
150
050 100 200
0.2 0.4 0.6 0.8
T , CASE TEMPERATURE (C)
C
V , INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Forward Current Derating Curve F
Fig. 2 Typical Forward Characteristics, per Element
2 of 4 May 2011
MBRB1530CT - MBRB1545CT
Diodes Incorporated
www.diodes.com
Document number: DS13015 Rev. 7 - 2
I, AVERAGE FORWARD CURRENT (A)
(AV)
I, INSTANTANEOUS FORWARD CURRENT (A)
F