Safety technique Emergency Stop Module BG 5924, IP 5924 safemaster According to EU directive for machines 98/37/EG According to IEC 204-1, DIN EN 60 204-1:1997, DIN VDE 0113-1 Safety category 4 according to DIN EN 954-1 Single channel operation Output: max. 4 NO contacts AC 230 V model with galvanic separation For thermal currents to 7 A LED indicator for channel 1 / 2 and state of operation Line fault detection on ON-button, terminal Y1 BG 5924 with: Removable terminal strips 2 Wire connection: also 2 x 1,5 mm stranded ferruled (isolated), DIN 46 228-4 or 2 2 x 2,5 mm stranded ferruled DIN 46 228-1/-2/-3 BG 5924 IP 5924 BG 5924: width 22,5 mm IP 5924: width 70 mm Function diagram Approvals and marking 1) 2) 2) Pushbutton 1) On for BG 5924 existing for IP 5924 pending 2) Canada / USA ET Canada / USA for BG 5924 Emergency stop (Off) Applications Protection of people and machines K1 Emergency stop circuits on machines Indicators K2 LED Netz: on, when supply connected LED K1/K2: on, when relay K1 and K2 energized M7218 Block diagrams BG 5924.48, BG 5924.48/207, IP 5924.48 BG 5924.02, BG 5924.02/207, BG 5924.04, BG 5924.04/207, IP 5924.02, IP 5924.04 All technical data in this list relate to the state at the moment of edition. We reserve the right BG 5924, IP 5924 / 30.10.01 d for technical improvements and changes at any time. 1 0225592Circuit diagrams A1 Y1 Y2 A1 Y1 Y2 13 23 23 13 23 33 43 A1 13 A1 13 23 A1 13 23 A1 13 23 33 43 Y1 Y1 Y1 K1 K1 K1 Y2 Y2 Y2 K2 K2 K2 A2 14 24 A2 14 24 A2 14 24 34 44 14 24 A2 14 24 14 24 34 44 M7129 M7130 M7386 a A2 A2 Y1 Y2 BG 5924.02 BG 5924.02/207 BG 5924.04 43 A1 Y1 Y2 41 13 A1 13 23 33 13 23 33 A1 23 33 A1 13 23 33 43 A1 13 23 33 41 A1 13 23 33 41 Y1 Y1 Y1 K1 K1 K1 Y2 Y2 Y2 K2 K2 K2 A2 14 24 34 44 A2 14 24 34 42 A2 14 24 34 42 A2 14 24 34 14 24 34 A2 14 24 34 M7131 M7385 a M7132 44 41 42 A2 42 Y1 Y2 Y1 Y2 BG 5924.04/207 BG 5924.48 BG 5924.48/207 A1 13 23 A1 13 23 33 43 A1 13 23 33 41 Y1 Y1 Y1 K1 K1 K1 Y2 Y2 Y2 K2 K2 K2 A2 14 24 A2 14 24 34 44 A2 14 24 34 42 A1 Y1 13 23 A1 Y1 13 23 33 43 A1 Y1 13 23 33 41 A2 Y2 14 24 A2 Y2 14 24 34 44 A2 Y2 14 24 34 42 M7912 M7913 M7911 IP 5924.04 IP 5924.02 IP 5924.48 Technical data Input Thermal current I : max. 7 A / 7 A** th BG 5924.04/207 Nominal voltage U : terminal 43/44: max. 5 A N BG 5924: DC 24 V BG 5924.48, BG 5924.48/207 AC/DC 24 V terminal 41/42: max. 5 A AC 230 V ** device mounted with distance to IP 5924: AC/DC 24, 48 V next device AC 110, 230 V (see total current limit curve) Voltage range: AC 0,8 ... 1,1 U Nominal output voltage: AC 250 V N at 10 % residual ripple: DC 0,9 ... 1,1 U Max. switching current: AC 8 A cos 1 ... 0,7 N at 48 % residual ripple: DC 0,8 ... 1,1 U Switching capacity N Nominal consumption to AC 15: 3 A / AC 230 V EN 60 947-5-1 AC/DC 24 V: DC 1,2 W AC 2 VA for NO contact AC 230 V: 3,5 VA 2 A / AC 230 V EN 60 947-5-1 Control voltage on Y1 for NC contact AC/DC 24 V: typ. DC 23 V Electrical life 5 AC 230 V: max. 45 V short pulse to AC 15 at 2 A, AC 230 V: 10 switching cycles EN 60 947-5-1 Control current: typ. DC 45 mA Permissible operating Recovery time: 0,5 s frequency: 600 switching cycles / h Short circuit strength Output max. fuse rating: 4 A gL EN 60 947-5-1 line circuit breaker: C 8 A 6 Contacts Mechanical life: 10 x 10 switching cycles BG 5924.02, IP 5924.02: 2 NO contacts BG 5924.04, IP 5924.04: 4 NO contacts General data BG 5924.48, IP 5924.48: 3 NO, 1 NC contacts Operate delay: max. 100 ms Operating mode: Continuous operation Release delay: max. 35 ms Temperature range: - 15 ... + 55 C Contact type: positive guided 2