DM85 industrial relays Cadmium - free contacts Height 15,7 mm 5000 V / 10 mm reinforced insulation For PCB and plug-in sockets Accessories: sockets and modules AC and DC coils Recyclable packing R Recognitions, certificates, directives: RoHS, VDE Contacts Contact number & arrangement 1C/O, 1NO Contact material AgNi, AgSnO 2 Max. switching voltage AC/DC 400 V / 300 V Min. switching voltage 5 V AgNi, 10 V AgSnO 2 Rated load AC1 16 A / 250 V AC DC1 16 A / 24 V DC Min. switching current 5 mA AgNi, 10 mA AgSnO 2 Max. inrush current 30 A AgSnO 2 Rated current 16 A Max. breaking capacity AC1 4 000 VA Min. breaking capacity 0,3 W AgNi, 1 W AgSnO 2 Resistance 100 m Max. operating frequency at rated load AC1 600 cycles/hour no load 72 000 cycles/hour Coil Rated voltage 50/60 Hz AC 12...240 V DC 3...110 V Must release voltage AC: 0,15 U DC: 0,1 U n n Operating range of supply voltage see Tables 1, 2 and Fig. 4, 5 Rated power consumption AC 0,75 VA DC 0,4...0,48 W Insulation Insulation category C250 / B400 Insulation rated voltage 400 V AC Rated surge voltage 4 000 V AC Overvoltage category III IEC 61810-5 (PN-IEC 664-1) Insulation pollution degree 3 Dielectric strength coil - contact 5 000 V AC contact - contact 1 000 V AC Contact - coil distance clearance 10 mm creepage 10 mm General data Operating time (typical value) 7 ms Release time (typical value) 3 ms Electrical life 5 resistive AC1 > 0,7 x 10 16 A, 250 V AC cos see Fig. 2 5 L/R=40 ms > 10 0,15 A, 220 V DC 7 Mechanical life (cycles) > 3 x 10 Dimensions (L x W x H) 29 x 12,7 x 15,7 mm Weight 14 g Ambient temperature o storage -40...+85 C o o operating AC: -40...+70 C DC: -40...+85 C Cover protection category IP 40 or IP 67 Environmental protection RTII IEC 61810-7 Shock resistance 30 g Vibration resistance 10 g 10...150 Hz o Solder bath temperature max. 270 C Soldering time max. 5 s Standard contact materials are marked with bold type. Page 1 of 4 www.aecsensors.com Sales Department Tel: (888) 847-6552DM85 industrial relays Coil data - DC voltage version Table 1 Coil operating range at 20 C Coil resistance Rated voltage V DC Coil code 10% at 20 C V DC min. max. 1003 3 22 2,1 7,6 1005 5 60 3,5 12,7 1006 6 90 4,2 15,3 1009 9 200 6,3 22,9 1012 12 360 8,4 30,6 1018 18 710 12,6 45,9 1024 24 1 440 16,8 61,2 1036 36 3 140 25,2 91,8 1048 48 5 700 33,6 122,4 1060 60 7 500 42,0 153,0 1110 110 25 200 77,0 280,0 Standard coil rated voltages marked with bold type. Coil data - AC 50/60 Hz voltage version Table 2 Coil operating range at 20 C Coil resistance Acceptable Rated voltage V AC - 50 Hz Coil code at 20 C resistance V AC min. max. 5012 12 100 10% 9,6 13,2 5024 24 400 10% 19,2 28,8 5048 48 1 550 10% 38,4 57,6 5060 60 2 600 10% 48,0 72,0 5110 110 8 900 10% 88,0 132,0 5115 115 9 600 10% 92,0 138,0 5120 120 10 200 10% 96,0 144,0 5220 220 35 500 10% 176,0 264,0 5230 230 38 500 10% 184,0 276,0 5240 240 42 500 15% 192,0 288,0 Standard coil rated voltages marked with bold type. Dimensions Connections diagrams (pin side view) 14 (8) 24 (5) 14 (8) 24 (5) 29 11 (7) 21 (4) 11 (7) 21 (4) 12 (6) 22 (3) A1 (1) A2 (2) A1 (1) A2 (2) 5515 2,5 1C/O 1NO Terminal (pin) A1(1) A2(2) 22(3) 21(4) 24(5) 12(6) 11(7) 14(8) mm 0,6 0,5 x 0,9 Drilling hole: for relays 1,3 + 0,1 mm for sockets 1,5 + 0,1 mm DM85 terminals are doubled for each contact. Both terminals are to be used while connecting to load. Page 2 of 4 www.aecsensors.com Sales Department Tel: (888) 847-6552 12,7 7,5 3,9 15,7