IKAstandarddistributionboard,IP65withoutclamps Partno. IKA-1/12-OT CatalogNo. 174206 EatonCatalogNo. IKA-1/12-OT Deliveryprogram Basic function Basic device Product function Installation distribution boards Product range IKA standard DBO Design Surface mounted Installation site Indoor Type of installation Surface mounting Door/Flap Transparent Degree of Protection IP65 Colour Grey Module rack Single-rail Shroud for protection against accidental contact Plastic Rows Count 1 Module units per row 12 Description IP65 Protection Class II Plastic enclosure gray (RAL 7035) Cable entries Metric cable entries on top and bottom, side, back plate PE and N terminals design Without Equipment supplied Basic device Device support rails Locking screws can be sealed Sealing caps Current circuit designation Technicaldata General Standards EN 62208, IEC/EN 60670-24 RoHS (in accordance with Directive 2002/95/EC of the European Parliament and conform Council) Ambient temperature C -25 - +40 Degree of Protection IP65 Protection class II (totally insulated) Rated operational voltage Ue V AC 415 Rated frequency f Hz 50 Materialcharacteristics Material ABS (plastic) Colour Gray (RAL 7035) Materialproperties Mechanical Impact resistance IK08 DesignverificationasperIEC/EN61439 Technical data for design verification Heat dissipation, at an ambient temperature of 35C, delta T: 20 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P CO 20 V Heat dissipation, at an ambient temperature of 35C, delta T: 35 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P CO 40 V IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard s requirements. 07/31/2017 174206 - HPL-ED2017 V34.0 EN 1 / 310.2.3.1 Verification of thermal stability of enclosures Meets the product standard s requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard s requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat 650 C meets the product standard s requirements. and fire due to internal electric effects 10.2.4 Resistance to ultra-violet (UV) radiation Not relevant to indoor installations. 10.2.5 Lifting Does not apply to enclosures without lifting aids. 10.2.6 Mechanical impact IK08 10.2.7 Inscriptions Meets the product standard s requirements. 10.3 Degree of protection of ASSEMBLIES IP65 10.4 Clearances and creepage distances Is the panel builder s responsibility. 10.5 Protection against electric shock Protection class 2, therefore not applicable. 10.6 Incorporation of switching devices and components Is the panel builder s responsibility. 10.7 Internal electrical circuits and connections Is the panel builder s responsibility. 10.8 Connections for external conductors Is the panel builder s responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength U = 1000 V AC i 10.9.3 Impulse withstand voltage 3.3kV 10.9.4 Testing of enclosures made of insulating material Meets the product standard s requirements. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder s responsibility. 10.12 Electromagnetic compatibility Is the panel builder s responsibility. 10.13 Mechanical function Meets the product standard s requirements. TechnicaldataETIM6.0 Distribution boards (EG000023) / Small distribution board (EC000214) Electric engineering, automation, process control engineering / Electrical installation, device / Electrical distribution system (incl. small distribution board) / Small distribution board (ecl ss8.1-27-14-24-09 ACN387008 ) Mounting method Surface mounting Number of rows 1 Width in number of modular spacings 12 Type of cover Door Cover model With notch Transparent cover/door Yes Material housing Plastic Height mm 246 Width mm 310 Depth mm 145 Built-in depth mm 70 Internal depth mm 60 DIN-rail Yes With mounting plate No Extension possible Yes EMC-version No Colour Grey RAL-number 7035 Degree of protection (IP) IP65 With lock No 07/31/2017 174206 - HPL-ED2017 V34.0 EN 2 / 3