Effective May 2017 Technical Data 2000 Supersedes June 2013 ABC 14 x 1 14 Fast-acting ceramic tube fuses Product features Fast-acting, ceramic tube Optional axial leads available 1 1 4 x 1 4 (6.4 x 31.7mm) physical size Ceramic tube, nickel-plated brass endcap construction UL Listed product meets standard 248-14 Agency information UL Listed Guide JDYX & File E19180 UL Recognition Guide JDYX2 & File E19180 CSA Certification: Class No: 1422-01 & ELECTRICAL CHARACTERISTICS 1422-30, File 53787 % of Amp Rating Opening Time 100% 4 Hours Minimum Ordering 135% 60 Minutes maximum 200% 120 Seconds Maximum Specify packaging, product and option code Specifications Voltage Vac Interrupting Vdc Interrupting Typical Typical Typical Part Ratings Ratings* (amps) Ratings (amps) DC Cold Pre-Arc Voltage Agency Approvals 2 Number Vac Vdc 250V 125V 125V 75V Resistance ( )** I t AC Drop (V) UL UR CSA 1 ABC- 4-R 250 125 35 10,000 10,000 2.950 0.0020 0.35 X X 1 ABC- 2-R 250 125 35 10,000 10,000 0.587 0.0390 0.41 X X 3 ABC- 4-R 250 125 35 10,000 10,000 0.300 0.1450 0.32 X X ABC-1-R 250 125 35 10,000 10,000 0.1950 0.4310 0.3 X X 1 ABC-1- 2-R 250 125 100 10,000 10,000 0.131 1.1630 0.28 X X ABC-2-R 250 125 100 10,000 10,000 0.0890 2.1670 0.31 X X 1 ABC-2- 2-R 250 125 100 10,000 10,000 0.061 4.4670 0.23 X X ABC-3-R 250 125 100 10,000 10,000 0.047 6.55 0.14 X X ABC-4-R 250 125 200 10,000 10,000 0.031 22.28 0.17 X X ABC-5-R 250 125 200 10,000 10,000 0.026 32.83 0.22 X X ABC-6-R 250 125 200 10,000 10,000 0.021 58 0.19 X X ABC-7-R 250 125 200 10,000 10,000 0.016 109.33 0.17 X X ABC-8-R 250 125 200 10,000 10,000 0.014 116.5 0.19 X X ABC-10-R 250 125 200 10,000 10,000 0.011 208.8 0.15 X X ABC-12-R 250 125 750 10,000 10,000 0.0068 133.3 0.1 X X ABC-15-R 250 125 750 10,000 10,000 0.00553 200.2 0.1 X X ABC-18-R 250 400 1000 0.00465 400 0.1 X X ABC-20-R 250 125 400 1000 10,000 0.00366 550.8 0.1 X X ABC-25-R 250 125 200 1000 400 1000 0.0028 839.3 0.09 X X ABC-30-R 250 125 200 1000 400 1000 0.002225 1429 0.09 X X * Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The interrupting ratings for 25A and 30A were measured at 89% power factor on AC. ** Typical DC cold resistance measured at <10% of rated current. Typical melting I2t measured at listed interrupting rating and rated voltage. Typical voltage drop measured at 25C3C ambient temperature at rated current. CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)ABC Technical Data 2000 Effective May 2017 14 x 1 14 Fast-acting ceramic tube fuses Dimensions - mm Drawing Not to Scale Time-Current Curves 1 3 15 18 12 25 20 10 5 8 30 Current in Amps PACKAGING CODE Packaging Code Description BK 100 pieces of fuses packed into a cardboard carton BK1 1000 pieces of fuses packed into a cardboard carton BK8 8000 pieces of fuses packed into a cardboard carton OPTION CODE Option Code Description V Axial leads - copper tinned wire with nickel plated brass overcaps Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Eaton Electronics Division 1000 Eaton Boulevard Cleveland, OH 44122 United States www.eaton.com/electronics 2017 Eaton Eaton is a registered trademark. All Rights Reserved Printed in USA All other trademarks are property Publication No. 2000 BU-SB13635 of their respective owners. May 2017 Time in Seconds