Low Voltage
Supplementary
Fuses
Low Voltage Supplementary Fuses
13 1
32x 1 2 Fast-acting fuses
BAF BAN KTK & KLM
Specifications
Class: Supplemental
Specifications Specifications
Description: Fast-
Class: Supplemental Class: Supplemental
acting supplementary
Description: Fast-acting Description: Fast-acting
fuse.
supplementary fuse. supplementary fuse.
13
Dimensions: 32 x
13 1 13 1
Dimensions: 32 x 1 2 Dimensions: 32 x 1 2
1
1 2 (10.3 x 38.1mm).
(10.3 x 38.1mm). (10.3 x 38.1mm).
Construction:
Construction: Fibre Construction: Fibre tube.
Melamine tube; nickel
cartridge; nickel plated
Ratings:
plated brass endcaps.
brass endcaps.
Volts 250Vac
Ratings:
Ratings:
Amps 1-30A
Volts KTK: 600Vac (or less)
2
Volts 250Vac ( 10-15A)
IR 35A (1.1-3.5A)
1 1
KLM: 500Vac/600Vdc ( 10A to 8A)
125Vac (20-30A)
100A (3.6-10A)
2
500Vac/dc ( 10-10A)
Amps 1-6A
200A (10.1-15A)
500Vac/600Vdc (12-30A)
2
IR 10,000A @ 125Vac ( 10-30A)
750A (15.1-30A) 1
Amps 10-30A
2
35A ( 10-1A @ 250Vac)
IR KTK: 100,000A RMS Sym. (UL)
1 Features and Benefits
100A (1 2-6A @ 250Vac)
Low cost supplemental protection of
KLM: 10,000A RMS Sym. (UL)
1
200A (6 4-10A @ 250Vac)
125V and 250V non-inductive
Agency Information: CE, Std. 248-14,
750A (12A- 15A @ 250Vac)
circuits.
KTK-UL Listed, Guide JDYX, File E19180,
Agency Information: CE, Std. 248-14,
Upgrade with LP-CC product to
KLM-UL Recognized, Guide JFHR2, File
UL 0-15/250V, Guide JDYX, File E19180
reduce SKU investment and mini-
E56412, CSA Certified, File 53787, Class
CSA Certified, 0-15/250V, Class
mize potential arc-flash hazards.
1422-01, HRC-Misc.
1422-01, File 53787.
(and
Features and Benefits
minimize potential for misapplying
Features and Benefits
Low cost supplemental protection of 600V
fuse.)
Low cost supplemental protection of
or less non-inductive circuits.
125V and 250V non-inductive circuits.
Typical Applications
Upgrade with LP-CC product to reduce
Upgrade with LP-CC product to reduce
General Purpose Circuits
SKU investment and minimize potential
SKU investment and minimize potential
Lighting Circuit Protection
arc-flash hazards.
arc-flash hazards. (and minimize
Meter Circuits
potential for misapplying fuse.) Typical Applications
Control Circuits
Catalog Numbers (Amps)
Typical Applications
Lighting Circuit Protection
BAN-1 BAN-5 BAN-12 BAN-30
General Purpose Circuits
Meter Circuits
BAN-2 BAN-6 BAN-15
Lighting Circuit Protection
Catalog Numbers (Amps)
BAN-3 BAN-8 BAN-20
Meter Circuits
600Vac - UL Listed and CSA
BAN-4 BAN-10 BAN-25
1 3
KTK- 10 KTK- 4 KTK-4 KTK-12 KTK-50
1
Catalog Numbers (Amps)
1
Recommended Fuse blocks 10 to 30A
KTK- 8 KTK-1 KTK-5 KTK-15
2
BAF- 10 BAF-2 BAF-8
2 1
KTK- 10 KTK-1 4 KTK-6 KTK-20
1 1
BAF- 4 BAF-2 2 BAF-9
Catalog Numbers
1 1
KTK- 4 KTK-1 2 KTK-7 KTK-25
1 Terminal Type
BAF- 2 BAF-3 BAF-10
3 1
Screw with Pressure Plate w/ KTK- 10 KTK-2 KTK-7 2 KTK-30
6
BAF- 10 BAF-4 BAF-12
Quick Connect Quick Connect Box Lug Poles
4 1
8 KTK- 10 KTK-2 2 KTK-8 KTK-35
BAF- 10 BAF-5 BAF-15
BM6031SQ BM6031PQ BM6031B 1
1
KTK- 2 KTK-3 KTK-9 KTK-40
BAF-1 BAF-6 BAF-20
BM6032SQ BM6032PQ BM6032B 2
1 1 6 1
BAF-1 2 BAF-6 4 BAF-25 KTK- 10 KTK-3 2 KTK-10 KTK-45
8 BM6033SQ BM6033PQ BM6033B 3
BAF-1 10 BAF-7 BAF-30
*500Vac/dc - UL Recognized and CSA.
*All have interrupting rating of 10,000A at 125V.
1 3
KLM- 10 KLM- 4 KLM-5 KLM-20
1
KLM- 8 KLM-1 KLM-6 KLM-25
Data Sheet: 2011 (0-30)
Data Sheet: 2046 (0-30)
2 1
KLM- 10 KLM-1 2 KLM-8 KLM-30
1
KLM- 4 KLM-2 KLM-10
For superior electrical protection, Cooper Bussmann recommends upgrading BAF,
3
KLM- 10 KLM-3 KLM-12
BAN and KTK fuse applications to Low-Peak LP-CC fuses See page 19.
1
KLM- 2 KLM-4 KLM-15
1 1
13 1
*KLM-( 10- 8A & 12-30A): 500Vac/600Vdc.
Recommended fuse blocks/fuse holders for 32x 1 2 fuses
See page 40
Data Sheets: KTK-1011 KLM-2020
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
43X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Industrial & Electrical Fuses category:
Click to view products by Eaton manufacturer:
Other Similar products are found below :
MTH-4 MTH-8 BCC-1-8/10 BP/FNM-5 BP/NON-30 KTN-R-10 LPS-RK-2SP ABU-15 ABU-25 ABU-3 ABU-35 ABU-50 ABU-60
TCF40RN BCF-10 BK-SC-20 FNM-6-1-4 FRN-R-6-1-4 FRS-R-3-12 KTK-1-1-2 BBS-610 FNM-6-10 FNQ-R-1-1-4 FRN-R-30ID FRS-
R-20ID CL03AB00M6 CHSF-80 BBS-1/10 LDFJ350.X KRP-C-700SP LPS-RK-3-2/10SP 3TX4431-0A BAF-4 KRP-C-1000SP TIA10
MIC-20 BBS-10 BBS-4/10 BBS-3/4 BBS-1/2 C10G32 C10M20 JJN-100 JJN-15 JJS-2 KTK-7 KTK-R-1-1/2 KTK-R-9 3RU1136-1KB0
LP-CC-12