HALOGEN 400Vdc/500-600Vac Time-Delay 5x20mm Fuses HF Pb S505H Series FREE Applications 5x20mm fuse with optional axial leads Power supplies - adapters Battery chargers Desktops/notebooks Printers B-SS 5MM fuse 2007-02 TVs / Displays Game systems Set top boxes Air conditioners Lighting ballasts Agency Information S505H-XXX-R (Ferrule) cURus approval: Guide JFHR2, File E56412 and Guide JFHR8, File E56412 CCC: 2A-4A, Cert. No.: 2010010207395946 5A-6.3A Cert. No.: 2010010207390567 CQC Approval: 8A-10A, Cert. No.: CQC10012043350 TUV Approval: 2A-10A, Cert. No.: R50172128 PSE Approval: 1A-5A, Cert. No.: JET1641-31003-1009 6.3A-10A, Cert. No: JET1641-31003-1011, Description S505H-V-XXX-R (Axial Leads) PSE Approval: 1A-5A, Cert. No.: JET1641-31003-1010 6.3A-10A, Cert. 400Vdc/500-600Vac Time-delay 5x20mm ceramic tube fuses with No: JET1641-31003-1012 electroplated end caps. The S505H Series provides higher voltage ratings and cURus approval: Guide JFHR2, File E56412 and Guide JFHR8, File E56412 breaking capacities than standard IEC 60127-2 fuses. Part Number System: TR2- S505H -V -2 -R Features Package Code Prefix Time-delay, high breaking capacity Series Number 5 x 20mm physical size Option Code Ceramic tube with plated end cap construction Fuse Amps Designed to IEC 60127-2, Standard, Sheet 5 RoHS Compliance RoHS Compliant, lead free and halogen free Ordering Optional axial leads available Specify product by package code prefix and option code. Specifications Typical Typical 2 Voltage Max. Voltage Interrupting Rating (A) Under DC Cold Voltage Typical Agency Approvals 1 Catalog Rating Rating 250 Max 400 Resistance Drop Value 250Vac 3 4 2 2 5 6 6 6 7 Number Vac AC DC Vac Volts Vdc (mV) I t (A s) TUV CQC CCC PSE/JET cURus S505H-500-R 250 600 400 1500 100 1500 0.507 295 0.188 x S505H-800-R 250 600 400 1500 100 1500 0.237 189 0.632 x S505H-1-R 250 600 400 1500 100 1500 0.14 153 1.28 X x S505H-1.25-R 250 600 400 1500 100 1500 0.108 150 2.22 X x S505H-1.6-R 250 600 400 1500 100 1500 0.07 125 6.78 X x S505H-2-R 250 600 400 1500 100 1500 0.055 128 11.44 X X X x S505H-2.5-R 250 600 400 1500 100 1500 0.04 126 24.23 X X X x S505H-3.15-R 250 600 400 1500 100 1500 0.031 121 43.55 X X X x S505H-4-R 250 600 400 1500 100 1500 0.019 90 38.45 X X X x S505H-5-R 250 600 400 1500 100 1500 0.015 89 71.3 X X X x S505H-6.3-R 250 500 400 1500 100 1500 0.011 80 111.4 X X X x S505H-8-R 250 500 400 1500 100 1500 0.007 76 228.2 X X X x S505H-10-R 250 500 400 1500 100 1500 0.006 72 349.5 X X X x 1. Max. Voltage rating: Base on the breaking capacity test according to UL. 3. Cold Resistance: Measure at <10% rated current. 2. - Breaking Capacity of 250VAC/1500A is tested by all agency approvals, test condition is 4. Typical Voltage Drop: Voltage drop is measured under ambient 20C with rated current 2 250Vac, PF: 0.7-0.8. 5. Typical Pre-Arc I t: Measured at 10I DC n - Breaking Capacity of Max. voltage is tested by UL, PF:1. 6. Does not apply to axial leaded versions. - Breaking Capacity Test of DC is tested by UL under Capacitor Bank 4800mF (for 400V, 1500A), 7. 600/500Vac, 400Vdc. 2400mF (for 400V, 500A). 1111 BU-SB11276 Page 1 of 3 Data Sheet 4406Dimensions - mm Electrical Characteristics 1.5I 2.1I 2.75I 4I 10I n n n n n Min Max Min Max Min Max Min Max Amps min. min. ms s ms s ms ms <1A >60 <30 >250 <80 >50 <5 >5 <150 1A-3.15A >60 <30 >750 <80 >95 <5 >10 <150 4A-6.3A >60 <30 >750 <80 >150 <5 >10 <150 8A-10A >30 <30 >750 <80 >150 <5 >10 <150 Construction Time-Current Curves 500-800mA 1-1.6 Amps 2 Amps & Above 1. Ceramic Tube 2. Wire Fuse Element 3. Plated Fuse Cap 4. Filler 5. Solder 6. Eyelet Current in Amps Axial Leaded Versions 1. S505H-XXX-R 2. Axial Leaded Cap 1111 BU-SB11276 Page 2 of 3 Data Sheet 4406 Time in Seconds