HALOGEN 5 x 20mm Medium Time-Delay Glass Tube Fuses HF Pb FREE GMC Series Electrical Characteristics Rated Current % of Amp Rating Opening Time 100% None 63mA - 10A 135% 60 minutes maximum 200% 2 minutes maximum Agency Information UL Listed, Guide JDYX, File E19180, 63mA-6.3A UL Recognized Card: (7A-10A) Guide JDYX2, File E19180 CSA Certified, Class 1422-01, File E65063, 63mA-6.3A MITI Approval, 1A-10A KC-Mark: Certificate SU05011-4001 (63mA~250mA) SU05011-4002 Description (300mA~800mA) SU05011-4003 (1A~3.15A) SU05011-4004 (3.5A~6.3A) Medium time-delay, low breaking capacity Ordering Available with optional axial leads 5 x 20mm physical size Specify packaging code prefix, product number and option code suffix Glass tube, nickel-plated brass endcap construction For RoHS compliant version (suffix -R), drop mA or A from product code Designed to UL/CSA 248-14 (e.g., GMC-2-R) Specifications Voltage Typical DC Cold Typical Maximum 2 Product Rating Interrupting Rating (Amps)* Resistance Pre-Arc I t Voltage Number Vac 250Vac 125Vac ()** AC Drop (mV) GMC-63mA 250 35 10,000 10.350 0.0027 1400 GMC-80mA 250 35 10,000 - 0.0050 1400 GMC-100mA 250 35 10,000 4.775 0.0094 1200 GMC-125mA 250 35 10,000 3.400 0.014 1000 GMC-150mA 250 35 10,000 2.555 0.022 800 GMC-160mA 250 35 10,000 2.295 0.022 730 GMC-200mA 250 35 10,000 1.395 0.032 650 GMC-250mA 250 35 10,000 0.965 0.046 490 GMC-300mA 250 35 10,000 0.838 0.081 580 GMC-315mA 250 35 10,000 0.685 0.081 480 GMC-400mA 250 35 10,000 0.615 0.18 510 GMC-500mA 250 35 10,000 0.335 0.41 370 GMC-600mA 250 35 10,000 0.282 0.60 360 GMC-630mA 250 35 10,000 0.246 0.66 360 GMC-700mA 250 35 10,000 0.213 0.85 340 GMC-750mA 250 35 10,000 0.213 0.85 320 GMC-800mA 250 35 10,000 0.180 0.85 290 GMC-1A 250 35 10,000 0.156 1.8 250 GMC-1.25A 250 100 10,000 0.098 3.4 200 GMC-1.5A 250 100 10,000 0.076 5.4 190 GMC-1.6A 250 100 10,000 0.067 5.8 160 GMC-2A 250 100 10,000 0.043 8.9 130 GMC-2.5A 250 100 10,000 0.035 13 130 GMC-3A 250 100 10,000 0.026 19 130 GMC-3.15A 250 100 10,000 0.025 23 130 GMC-3.5A 125 - 10,000 0.022 25 130 GMC-4A 125 - 10,000 0.019 36 120 GMC-5A 125 - 10,000 0.014 58 120 GMC-6A 125 - 10,000 0.013 88 120 GMC-6.3A 125 - 10,000 0.012 110 120 GMC-7A 125 - 200 0.012 150 120 GMC-8A 125 - 200 0.009 200 110 GMC-10A 125 - 200 0.007 300 110 * Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC. ** DC Cold Resistance (Measured at <10% of rated current) 2 2 Typical Pre-Arching I t (I t was measured at listed interrupting rating and rated voltage) Maximum Voltage drop (Voltage drop was measured at 20C ambient temperature at rated current) 0711 BU-SB11757 Page 1 of 2 Data Sheet 4395Dimensions - mm Time-Current Curves Drawing Not to Scale 38.10mm (.38) 5.54mm (.20) AMP RATING 100 10mm 20mm 21.10mm (2.0) (0.5) (.81) 5.2mm 10 38.10mm (+0.1/-0.2) (.38) 0.65mm (REF) Ratings above 6.3A have a 0.8mm diameter lead With TR2 packaging code, lead wire length is 19.05mm 1 .1 .01 CURRENT IN AMPS Packaging Code Product Number Prefix Description BK- 100 fuses packed into a cardboard carton BK1- 1000 fuses packed into a poly bag TR2- 1500 Axial lead fuses packed into tape on a reel (19.05mm lead wire length) Option Code Product Number Suffix Description -V Axial leads - copper tinned wire with nickel plated brass overcaps (place before amp rating e.g., GMC-V-2) -R RoHS compliant version (drop mA or A from product number when ordering) The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information con- tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life sup- port systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. 2011 Cooper Bussmann www.cooperbussmann.com 0711 BU-SB11757 Page 2 of 2 Data Sheet 4395 TIME IN SECONDS 63mA .1 80mA 100mA 125mA 150mA 200mA 250mA 300mA 315mA 400mA 500mA 750mA 800mA 1 1A 1.5A 1.6A 2A 2.5A 3A 3.5A 5A 4A 6A 6.3A 10 7A 8A 10A 100