Bussmann
Automotive In-Line Fuseholder HHC, HHD,
For ATC Blade-Type Fuses
HHF, & HHG
Dimensional Data
0.78"
0.364"
0.91"
0.5"
0.30"
0.38"
0.25"
+ +
4.0" 0.25" 1.125" 4.0" 0.25"
CATALOG SYMBOL: HHC, HHD, HHF, AND HHG COVER FOR HHD FUSEHOLDER
IN-LINE FUSEHOLDERS
RATED 32Vdc MAXIMUM CATALOG SYMBOL:
CURRENT RATING: See Table HHD-C
Electrical Ratings
Catalog Fuse Electrical Maximum Continuous
Symbol Description Size Connection Current Rating
HHC Yellow fuseholder 3-20A #16 black leadwire 16A*
HHD Black fuseholder 3-30A #12 yellow leadwire 24A*
Fits HHD
HHD-C Cover only Clear polycarbonate
only
HHF Black fuseholder 3-20A #16 yellow leadwire 16A*
with cover
HHG Black fuseholder 3-30A #12 yellow leadwire 24A*
with cover
* Or 80% of fuse rating, whichever is less.
For ATC blade-type fuses.
Write-in space for circuit identification on HHC holders (bright yellow).
Bulk Products
(Bulk Quantity - 1000 pieces)
Catalog Fuse Electrical Maximum Continuous
Symbol Description Size Connection Current Rating
BK/HHC-R Yellow fuseholder 3-20A #16 red leadwire 16A*
BK/HHF-B Black fuseholder 3-20A #16 black leadwire 16A*
with cover
* Or 80% of fuse rating, whichever is less.
A fuse must be properly and fully inserted into the holder to
provide a solid connection. Poor or improper insertion of the
fuse can result in failure of the fuse and holder, thus not
protecting the device for which it was intended.
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this Data Sheet are by definition uncontrolled. This bulletin is intended to clearly
present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products
and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it
should be tested by the user in all possible applications.
Form No. HHC, HHD ,HHF and HHG
Page 1 of 1
1-22-03 SB03020 Data Sheet: 2107