Softstarter,3p,32A,200-480VAC,us=110/230VAC Partno. DS7-342SX032N0-N Articleno. 134932 CatalogNo. DS7-342SX032N0-N Deliveryprogramme Description With internal bypass contacts Function Soft starters for three-phase loads Mains supply voltage (50/60 Hz) U V AC 200 - 480 LN Supply voltage U 110 - 230 V AC s Control voltage U 110 - 230 V AC C Assignedmotorrating(Standardconnection,In-Line) at 400 V, 50 Hz P kW 15 at 460 V, 60 Hz P HP 25 Ratedoperationalcurrent AC-53 I A 32 e Startup class CLASS 10 (star-delta replacement) CLASS 20 (heavy starting duty 3 x I for 45 s) e Rated operational voltage U 200 V e 230 V 400 V 480 V Connection to SmartWire-DT no Technicaldata General Standards IEC/EN 60947-4-2 UL 508 CSA22.2-14 Approvals CE Approvals UL CSA C-Tick UkrSEPRO Climatic proofing Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Ambient temperature Operation C -5 - +40 up to 60 at 2% derating per Kelvin temperature rise Storage C -25 - +60 Altitude m 0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m Mounting position Vertical Degree of protection Degree of Protection IP20 Protection against direct contact Finger- and back-of-hand proof Overvoltage category/pollution degree II/2 Shock resistance 8 g/11 ms Vibration resistance to EN 60721-3-2 2M2 Radio interference level (IEC/EN 55011) A Static heat dissipation, non-current-dependent P W 1.5 vs Weight kg 0.45 Mainconductingpaths Rated operating voltage U V AC 200 - 480 e Supply frequency f Hz 50/60 LN 03/18/2016 134932 - HPL-ED2016 V20.0 EN 1 / 5Rated operational current I A e AC-53 I A 32 e Assigned motor rating (Standard connection, In-Line) at 230 V, 50 Hz P kW 7.5 at 400 V, 50 Hz P kW 15 at 200 V, 60 Hz P HP 10 at 230 V, 60 Hz P HP 10 at 460 V, 60 Hz P HP 25 Overload cycle to IEC/EN 60947-4-2 AC-53a 32 A: AC-53a: 3 - 5: 75 - 10 Internal bypass contacts Short-circuit rating Type 1 coordination PKM0-32 (+ CL-PKZ0) Type 2 coordination (additional with the fuses for coordination type 1) 3 x 170M1366 Fuse base (number x part no.) 3 x 170H1007 Terminalcapacities Cable lengths 2 Solid 1 x (0.75 - 16) mm 2 x (0.75 - 10) 2 Flexible with ferrule 1 x (0.75 - 16) mm 2 x (0.75 - 10) 2 Stranded 1 x 16 mm Solid or stranded AWG 18 - 6 Tightening torque Nm 3.2 Screwdriver (PZ: Pozidriv) mm PZ2 1 x 6 mm Control cables 2 Solid 1 x (0.5 - 2.5) mm 2 x (0.5 - 1.0) 2 Flexible with ferrule 1 x (0.5 - 1.5) mm 2 x (0.5 - 0.75) 2 Stranded 1 x (0.5 - 1.5) mm 2 x (0.5 - 1.0) Solid or stranded AWG 1 x (21 - 14) 2 x (21 - 18) Tightening torque Nm 1.2 Screwdriver mm 0,8 x 5,5 1 x 6 Controlcircuit Digital inputs Control voltage AC operated V AC 110 V AC - 15 % - 230 V AC +10 % Current consumption 24 V mA External 24 V mA 1.6 Current consumption 230 V mA 4 Pick-up voltage x U s AC operated V AC 108 - 253 Drop-out voltage x U s AC operated V AC 0 - 15 Pick-up time AC operated ms 250 Drop-out time AC operated ms 350 Regulator supply Voltage U V 110 V AC -15 % - 230 V AC +10 % s Current consumption I mA 50 e Notes External supply voltage 03/18/2016 134932 - HPL-ED2016 V20.0 EN 2 / 5