Current and Voltage Sensors 7.7 CurrentWatch EAC Series 1 Standards and Certifications DANGER 7 UL Listed THIS SENSOR IS NOT A cUL Listed SAFETY DEVICE AND IS NOT 7 CE Certified INTENDED TO BE USED AS A UL 508 Industrial Control SAFETY DEVICE. This sensor 7 Equipment (USA and is designed only to detect Canada) and read certain data in an 7 electronic manner and perform no use apart from 7 that, specifically no safety- related use. This sensor product does not include 7 self-checking redundant circuitry, and the failure of 7 this sensor product could cause either an energized 7 or de-energized output condition, which could result 7 in death, serious bodily injury, or property damage. 7 Product Selection 7 EAC Series CurrentWatch Current Sensors 7 Top Terminal Current Sensors Power Supply Aperture Size Output Signal Current Range Catalog Number 7 Solid-Core Housing Solid-Core Housings Self-powered 0.74 in (19 mm) 05 Vdc 10, 20 or 50A EAC105SC 7 (no external power needed) 100, 150 or 200A EAC205SC 7 010 Vdc 10, 20 or 50A EAC110SC 100, 150 or 200A EAC210SC 7 24 Vdc loop-powered 420 mA 2 or 5A EAC0420SC 10, 20 or 50A EAC1420SC 7 100, 150 or 200A EAC2420SC Split-Core Housing Split-Core HousingsSelf-Powered and 24 Vdc 7 Self-powered 0.85 in (21.6 mm) 05 Vdc 10, 20 or 50A EAC105SP (no external power needed) 7 100, 150 or 200A EAC205SP 010 Vdc 10, 20 or 50A EAC110SP 7 100, 150 or 200A EAC210SP 24 Vdc loop-powered 420 mA 2 or 5A EAC0420SP 7 10, 20 or 50A EAC1420SP 7 100, 150 or 200A EAC2420SP Split-Core Housing Split-Core Housings120 Vac and 24 Vac/dc 7 2 120 Vac 0.85 in (21.6 mm) 420 mA 2 or 5A EACP0420120SP 2 10, 20 or 50A EACP1420120SP 7 2 100, 150 or 200A EACP2420120SP 2 24 Vac/dc 420 mA 2 or 5A EACP042024USP 7 2 10, 20 or 50A EACP142024USP 2 7 100, 150 or 200A EACP242024USP Notes 7 1 EACP models not listed. 2 Not UL listed. 7 7 7 Volume 8Sensing Solutions CA08100010EAugust 2012 www.eaton.com V8-T7-27Current and Voltage Sensors 7.7 CurrentWatch EAC Series Accessories 7 EAC Series CurrentWatch Current Sensors DIN Rail 7 Mounting Kit Description Catalog Number 1 DIN rail mounting kit EDINKIT 7 7 7 7 7 Technical Data and Specifications EAC Series CurrentWatch Current Sensors 7 EACP Series Only Models with 05 Vdc Output Models with 010 Vdc Output Models with 420 mA Output Description Specification Specification Specification Specification 7 Power supply Self-poweredno power supply needed Self-poweredno power supply needed 1240 Vdc loop-powered Models ending -0SP: 120 Vac Models ending -USP: 24 Vac/dc 7 (40V maximum) Output signal 05 Vdc 010 Vdc 420 mA 420 mA 7 Output limit 8.2 Vdc 15 Vdc 23 mA 22.4 mA Accuracy 1.0% FS 1.0% FS 1.0% FS 1% FS 7 Response time 100 ms 100 ms 300 ms 100 ms 7 Frequency range 5060 Hz 5060 Hz 20100 Hz 40100 Hz Loading 1M ohm minimum rated accuracy 1M ohm minimum rated accuracy See power supply above 50 kohms minimum 7 100 kohms, add 1.3% error 100 kohms, add 1.3% error 500 kohms maximum Isolation voltage UL listed to 1270 Vac (tested to 5kV) UL listed to 1270 Vac (tested to 5kV) UL listed to 1270 Vac (tested to 5kV) UL listed to 1270 Vac (tested to 5kV) 7 3 3 3 Input ranges Field selectable ranges from 0200A Field selectable ranges from 0200A Field selectable ranges from 0200A 0200A jumper selectable Sensing aperture Solid-core: 0.74 in (19 mm) dia. Solid-core: 0.74 in (19 mm) dia. Solid-core: 0.74 in (19 mm) dia. 0.85 in (21.6 mm) 7 Split-core: 0.85 in (21.6 mm) sq. Split-core: 0.85 in (21.6 mm) sq. Split-core: 0.85 in (21.6 mm) sq. Housing UL94 V0 flammability rated UL94 V0 flammability rated UL94 V0 flammability rated UL94 V0 flammability rated 7 Environmental Operating temperature: Operating temperature: Operating temperature: Operating temperature: 4 to 122F (20 to 50C) 4 to 122F (20 to 50C) 4 to 122F (20 to 50C) 4 to 122F (20 to 50C) 7 Humidity: 095% RH, non-condensing Humidity: 095% RH, non-condensing Humidity: 095% RH, non-condensing Humidity: 095% RH, non-condensing Notes 7 1 Sensor pictured for reference and not included in kit. 2 Does not apply to EACP series. 3 Additional custom ranges available from factory. 7 7 7 7 7 7 7 7 7 7 7 V8-T7-28 Volume 8Sensing Solutions CA08100010EAugust 2012 www.eaton.com