Engineering Safety & Productivity Photocells for use with LED and H.I.D. Products Cooper Crouse-Hinds factory-sealed, eld installed photocells offer reliable, dusk-to-dawn lighting control for walkways, security lighting and any other outdoor lighting application. Applications Features Certi cations Cooper Crouse-Hinds photocells are Makes retro tting xtures easy - D2S Series designed: existing photocells in lighting system CSA Standard: C22.2 No. 55 can still be utilized To provide control for automatic Dry Locations dusk-to-dawn lighting Solid-state design for performance UL Ordinary Locations and dependability For safety by turning on outdoor luminaires in critical passageways Luminaires turn on at 3 footcandles, EV2IH Series at night off at 8 footcandles, ensuring that NEC/CEC: the luminaires are operating only To save energy by operating when needed Class I, Divisions 1 and 2, luminaires only when necessary Groups B, C, D Built-in 10 second time delay to For use with LED luminaires (VMVL, eliminate nuisance tripping Class II, Division 1, Groups E, F, G FMVL, V2L, EVLL, EV LED, LPL, and Pro Series) and H.I.D. luminaires Eight-year operating life Class II, Division 2, Groups F, G (LMV, DMV, VMV, VMV High V2PCT photocell is rated for 65C Class III Wattage, and FMV Series) ambient and up to 1000W, 1000VA NEMA: 3, 4, 7BCD, 9EFG For use on 20-400 watt LED, H.I.D., UL Standard: 844 - Hazardous incandescent, or uorescent lighting (Classi ed) Locations luminaires CSA Standard: C22.2 No. 30, 55 For remote mounting in FS boxes (D2S Series) *For Group B applications, seal within 1 of enclosure in accordance with Section 501-5 of the National Electric For mounting in EIH enclosures Code . for Class I, Division 1 applications (EV2IH Series)Photocells for use with LED and H.I.D. Products Ordering Information Photocell in DS Cover for use with FS/FD Box Catalog Number Voltage Range Current Rating D2S20 120V, 50/60 Hz 8.33A 4.81A-3.61A D2S208 277 208V-277V depending on voltage Can be used with the following LED luminaires: Champ VMV LED Champ FMV LED Vaporgard LED Pro Series LED Photocell in EIH enclosure for use in Cl. I, Div. 1, Gr. B, C, D Cl. II, Div. 1, Gr. E, F, G Cl. III locations Catalog Number Voltage Range Current Rating EV2IH20 120V, 50/60 Hz 8.33A 4.81A-3.61A EV2IH208 277 208V-277V, 50/60 Hz depending on voltage Can be used with the following LED luminaires: HazardGard EVLL LED EV LED HazardGard LPL LED Replacement photocell for D2S cover or EIH enclosure* Catalog Number Voltage Range Current Rating V2PCT20 120V, 50/60 Hz 8.33A 4.81A-3.61A V2PCT208 277 208V-277V, 50/60 Hz depending on voltage Can be used with the following LED luminaires: Champ VMV LED Champ FMV LED Vaporgard LED Pro Series LED *Must be factory installed in Canada. When mounting in EIH enclosures for Class I, Division 1 applications (EV2IH Series), seals are not required for Groups C and D.