Industrial miniature circuit breakers UL 489 DIN rail miniature circuit breakers Features Optimum product quality, tested reliability and safety stand for the best protection of personnel, Complete range of ULT 489 Fulfill UL 489, CSAT C22.2 Listed DIN rail mounted No. 5 and also IEC 60947-2 installations and plant. Eatons FAZ-NA DIN rail miniature circuit breakers, St andard mountable circuit breakers are designed for use up to 40A current rating For use in applications for in branch service applications. Rated for 10 kAIC at which UL 1077 or CSA C22.2 277/480 Vac No. 235 are also allowed Current limiting design Field-inst allable shunt trip provides fast short-circuit and auxiliar y switch interruption, reducing the subsequent mounting let-through energy that Separate version for can damage the circuit ring tongue connection Suit able for branch circuit (Type FAZ-RT) terminal device protection screws can be removed (on both sides) Thermal-magnetic overcurrent protection Module width of only 17.7 mm (per pole) Three levels of short-circuit protection, categorized by Cont act position indicator B, C and D cur ves (red/green) Trip-free designbreaker Easy inst allation on DIN rail can not be defeated by Possibilit y for sealing holding the handle in the the toggle in ON or ON position OFF position Captive screws cannot be lost Complements UL 1077 offering SWD (switching dut y) suit able for switching fluorescent lighting loads (I 20A) nFAZ-NA UL 489 miniature circuit breakers catalog numbering system FAZ - C 6 / 1 - NA - SP Single Packaging Breaker Family Trip Characteristic Terminal SP = Single packaging FAZ = FAZ UL Ampere Rating Number of Poles A B = 35X I NA = UL 489 branch circuit for C and D curve, circuit breaker n 0.5 = 0.5A 10 = 10A 1 = Single-pole A C = 510X I with screw terminals single-pole only n 1 = 1A 13 = 13A 2 = Two-pole A D = 1020X I RT = UL 489 branch circuit Blank = Standard packaging n 1.5 = 1.5A 15 = 15A 3 = Three-pole with ring tongue terminals 2 = 2A 16 = 16A DC = UL 489 branch circuit at 3 = 3A 20 = 20A 125 Vdc per pole 4 = 4A 25 = 25A 5 = 5A 30 = 30A 6 = 6A 32 = 32A 7 = 7A 35 = 35A 8 = 8A 40 = 40A A I = Rated current for instantaneous trip characteristics. n FAZ-NA UL 489 circuit breakers10 kAIC A A A A2 A A Single-Pole Two-Pole Three-Pole Single-Pole Two-Pole Three-Pole Amperes Catalog Number Catalog Number Catalog Number Amperes Catalog Number Catalog Number Catalog Number D Curve (1020X I Current Rating) B Curve (35X I Current Rating) n n 1 FAZ-B1/1-NA FAZ-B1/2-NA FAZ-B1/3-NA 0.5 FAZ-D0.5/1-NA-SP FAZ-D0.5/2-NA FAZ-D0.5/3-NA 1.5 FAZ-B1.5/1-NA FAZ-B1.5/2-NA FAZ-B1.5/3-NA 1 FAZ-D1/1-NA-SP FAZ-D1/2-NA FAZ-D1/3-NA 2 FAZ-B2/1-NA FAZ-B2/2-NA FAZ-B2/3-NA 1.5 FAZ-D1.5/1-NA-SP FAZ-D1.5/2-NA FAZ-D1.5/3-NA 3 FAZ-B3/1-NA FAZ-B3/2-NA FAZ-B3/3-NA 2 FAZ-D2/1-NA-SP FAZ-D2/2-NA FAZ-D2/3-NA 3 FAZ-D3/1-NA-SP FAZ-D3/2-NA FAZ-D3/3-NA 4 FAZ-B4/1-NA FAZ-B4/2-NA FAZ-B4/3-NA 5 FAZ-B5/1-NA FAZ-B5/2-NA FAZ-B5/3-NA 4 FAZ-D4/1-NA-SP FAZ-D4/2-NA FAZ-D4/3-NA 6 FAZ-B6/1-NA FAZ-B6/2-NA FAZ-B6/3-NA 5 FAZ-D5/1-NA-SP FAZ-D5/2-NA FAZ-D5/3-NA 7 FAZ-B7/1-NA FAZ-B7/2-NA FAZ-B7/3-NA 6 FAZ-D6/1-NA-SP FAZ-D6/2-NA FAZ-D6/3-NA 8 FAZ-B8/1-NA FAZ-B8/2-NA FAZ-B8/3-NA 7 FAZ-D7/1-NA-SP FAZ-D7/2-NA FAZ-D7/3-NA 8 FAZ-D8/1-NA-SP FAZ-D8/2-NA FAZ-D8/3-NA 10 FAZ-B10/1-NA FAZ-B10/2-NA FAZ-B10/3-NA 13 FAZ-B13/1-NA FAZ-B13/2-NA FAZ-B13/3-NA 10 FAZ-D10/1-NA-SP FAZ-D10/2-NA FAZ-D10/3-NA 15 FAZ-B15/1-NA FAZ-B15/2-NA FAZ-B15/3-NA 13 FAZ-D13/1-NA-SP FAZ-D13/2-NA FAZ-D13/3-NA 16 FAZ-B16/1-NA FAZ-B16/2-NA FAZ-B16/3-NA 15 FAZ-D15/1-NA-SP FAZ-D15/2-NA FAZ-D15/3-NA 20 FAZ-B20/1-NA FAZ-B20/2-NA FAZ-B20/3-NA 16 FAZ-D16/1-NA-SP FAZ-D16/2-NA FAZ-D16/3-NA 20 FAZ-D20/1-NA-SP FAZ-D20/2-NA FAZ-D20/3-NA 25 FAZ-B25/1-NA FAZ-B25/2-NA FAZ-B25/3-NA 30 FAZ-B30/1-NA FAZ-B30/2-NA FAZ-B30/3-NA 25 FAZ-D25/1-NA-SP FAZ-D25/2-NA FAZ-D25/3-NA 32 FAZ-B32/1-NA FAZ-B32/2-NA FAZ-B32/3-NA 30 FAZ-D30/1-NA-SP FAZ-D30/2-NA FAZ-D30/3-NA C 35 FAZ-B35/1-NA FAZ-B35/2-NA FAZ-B35/3-NA 32 FAZ-D32/1-NA-SP FAZ-D32/2-NA FAZ-D32/3-NA C C 40 FAZ-B40/1-NA FAZ-B40/2-NA FAZ-B40/3-NA 35 FAZ-D35/1-NA-SP FAZ-D35/2-NA FAZ-D35/3-NA C 40 FAZ-D40/1-NA-SP FAZ-D40/2-NA FAZ-D40/3-NA A For ring tongue terminals, remove suffix NA and add suffix RT. A2 A A Single-Pole Two-Pole Three-Pole B For single packaging on single-pole C and D curves only, add suffix SP when ordering. Amperes Catalog Number Catalog Number Catalog Number C 240 Vac only. C Curve (510X I Current Rating) n 0.5 FAZ-C0.5/1-NA-SP FAZ-C0.5/2-NA FAZ-C0.5/3-NA 1 FAZ-C1/1-NA-SP FAZ-C1/2-NA FAZ-C1/3-NA 1.5 FAZ-C1.5/1-NA-SP FAZ-C1.5/2-NA FAZ-C1.5/3-NA 2 FAZ-C2/1-NA-SP FAZ-C2/2-NA FAZ-C2/3-NA 3 FAZ-C3/1-NA-SP FAZ-C3/2-NA FAZ-C3/3-NA 4 FAZ-C4/1-NA-SP FAZ-C4/2-NA FAZ-C4/3-NA 5 FAZ-C5/1-NA-SP FAZ-C5/2-NA FAZ-C5/3-NA 6 FAZ-C6/1-NA-SP FAZ-C6/2-NA FAZ-C6/3-NA 7 FAZ-C7/1-NA-SP FAZ-C7/2-NA FAZ-C7/3-NA 8 FAZ-C8/1-NA-SP FAZ-C8/2-NA FAZ-C8/3-NA 10 FAZ-C10/1-NA-SP FAZ-C10/2-NA FAZ-C10/3-NA 13 FAZ-C13/1-NA-SP FAZ-C13/2-NA FAZ-C13/3-NA 15 FAZ-C15/1-NA-SP FAZ-C15/2-NA FAZ-C15/3-NA 16 FAZ-C16/1-NA-SP FAZ-C16/2-NA FAZ-C16/3-NA 20 FAZ-C20/1-NA-SP FAZ-C20/2-NA FAZ-C20/3-NA 25 FAZ-C25/1-NA-SP FAZ-C25/2-NA FAZ-C25/3-NA 30 FAZ-C30/1-NA-SP FAZ-C30/2-NA FAZ-C30/3-NA 32 FAZ-C32/1-NA-SP FAZ-C32/2-NA FAZ-C32/3-NA C 35 FAZ-C35/1-NA-SP FAZ-C35/2-NA FAZ-C35/3-NA C 40 FAZ-C40/1-NA-SP FAZ-C40/2-NA FAZ-C40/3-NA Eaton Corporation Electrical Sector 1111 Superior Avenue Cleveland, OH 44114 USA Eaton.com Eaton is a registered trademark 2013 Eaton Corporation All Rights Reser ved of Eaton Corporation. Printed in USA All other trademarks are propert y Publication No. PA011010 03E / Z12781 Januar y 2013 of their respective owners.