Auxiliarycontact,forFAZ,PKNM,2W,0.5HP Partno. FAZ-XAM002 CatalogNo. 262414 EatonCatalogNo. FAZ-XAM002 EL-Nummer 1695385 (Norway) Deliveryprogram Basic function Accessories for miniature circuit-breaker Basic function accessories Auxiliary contacts Product range Accessory Contact sequence Technicaldata Electrical Contact function 2 C/O Rated operational voltage U V AC 250 e Rated frequency f Hz 50/60 Rated current I A 4 e Conventional free air thermal current I A 4 th Rated operational current AC-15 I A 2 (250 V AC) e AC-12 I A 3 (250 V AC) e DC-13 I A 0.5 (110 V DC) e Rated insulation voltage U V AC 250 i Minimum operating voltage per contact U V DC 5 min Rated impulse withstand voltage U kV 2.5 imp Rated conditional short-circuit current With 6 A back-up fuse I kA 1 sc Max. admissible back-up fuse A gL Max. admissible back-up fuse A gL 4 Mechanical Standard front dimension mm 45 Enclosure height mm 80 Mounting width mm 8.8 (0.5 space unit) Mounting On MCB Degree of protection Integrated IP40 Terminal protection Protection against electric shock to IEC 536 Terminals Lift terminals 2 Terminal capacities mm 2 Solid 0.5 2.5 mm 2 flexible 0.5 2.5 mm Tightening torque of terminal screws Nm 0.8 1.0 DesignverificationasperIEC/EN61439 Technical data for design verification 10/03/2017 262414 - HPL-ED2017 V36.0 EN 1 / 3Operating ambient temperature min. C -5 Operating ambient temperature max. C 40 TechnicaldataETIM6.0 Devices for distribution board-/surface mounting (EG000062) / Auxiliary contact unit for distribution board (EC001286) Electric engineering, automation, process control engineering / Electrical installation, device / Breaker switch component / Auxiliary contact unit for distribution board (ecl ss8.1-27-14-35-02 AKE327010 ) Device fitting Earth leakage circuit breaker and miniature circuit breaker (MCB) Additional equipment - Attached at delivery No Assembly width (TE) 0.5 Number of normally open contacts 0 Number of normally closed contacts 0 Number of change-over contacts 2 Number of fault-signal switches 0 Rated switch current A 3 Nominal rated voltage V 250 Control voltage type AC With autotest for earth leakage function No Suitable for max. number of poles main contact unit (total) 2 Suitable for max. current main contact unit A 0 Approvals Product Standards IEC/EN 60947-2 IEC/EN 60898 UL 1077 CSA-C22.2 No. 235 CE marking UL File No. E177451 UL Category Control No. QVNU2, QVNU8 CSA File No. CSA Class No. 3215-30 North America Certification UL recognized, certified by UL for use in Canada Degree of Protection IEC: IP20 UL/CSA Type: - 10/03/2017 262414 - HPL-ED2017 V36.0 EN 2 / 3