FUSETRON 600V Class RK5 1 FRS-R 600Vac/300Vdc, 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5.5 5 ( 0.31) ( 0.31) 0.81 (0.008) 1.06 (0.008) 1/10 to 30A 35 to 60A Description: Advanced protection, energy efficient Class RK5 Features: Provides motor overload, ground fault and short-circuit dual element, current-limiting, time-delay fuses with optional protection. When used in circuits subject to surge currents open fuse indication on select ratings. such as those caused by motors, transformers and other Time-delay 10 second (minimum) at 500% of rated current. inductive components, these fuses can be sized close to full-load amps to give maximum overcurrent protection. Catalog Symbol: FRS-R-(amp) (non-inducating) Permits the use of smaller and less costly switches. The FRS-R-(amp)ID (indicating time-delay feature makes it possible to use fuse amp ratings Ratings: which are much smaller than those of non-time delay fuses. 1 Volts 600Vac, 300Vdc ( 10-30A) Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves. 600Vac, 250Vdc (35-60A) Provides a higher degree of short-circuit protection (greater 1 Amps 10-60A current-limitation) in circuits in which surge currents or IR 200kA Vac RMS Sym. temporary overloads occur. Helps protect motors against burnout from overloads 20kA Vdc Gives motor running back-up protection to motors without Agency Information: extra costs Helps protect motors against burnout from single phasing CE, UL Listed, Std. 248-12, Class RK5, Guide JDDZ, on three phase systems File E4273 Simplifies and improves blackout prevention CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787 (selective coordination) Catalog Numbers (amps) Non-indictaing fuses Dual-element fuses can be applied in circuits subject to 1 8 temporary motor overloads and surge currents to provide FRS-R- 10 FRS-R-1 10 FRS-R-8* 1 both high-performance, short-circuit and overload FRS-R- 8 FRS-R-2 FRS-R-9* 15 1 protection FRS-R- 100 FRS-R-2 4 FRS-R-10* 2 1 The overload element provides protection against low level FRS-R- 10 FRS-R-2 2 FRS-R-12* 1 8 overcurrent of overloads and will hold an overload which is FRS-R- 4 FRS-R-2 10 FRS-R-15* 3 1 five times greater than the amp rating of the fuse for a FRS-R- 10 FRS-R-3 FRS-R-17 2* 4 2 minimum of ten seconds FRS-R- 10 FRS-R-3 10 FRS-R-20* 1 1 FRS-R- 2 FRS-R-3 2 FRS-R-25* Recommended Fuse Blocks 6 FRS-R- 10 FRS-R-4 FRS-R-30* Fuse Amps 1-Pole 2-Pole 3-Pole 8 1 FRS-R- 10 FRS-R-4 2 FRS-R-35* 0-30 R60030-1 R60030-2 R60030-3 FRS-R-1 FRS-R-5 FRS-R-40* 35-60 R60060-1 R60060-2 R60060-3 1 6 FRS-R-1 8 FRS-R-5 10 FRS-R-45* 1 For additional information on the R600 Series of 600 volt fuse FRS-R-1 4 FRS-R-6* FRS-R-50* 4 1 blocks, see Data Sheet 1111. FRS-R-1 10 FRS-R-6 4* FRS-R-60* 1 FRS-R-1 2 FRS-R-7* Fuse Reducers For Class R Fuses 6 1 FRS-R-1 10 FRS-R-7 2* Equipment Desired Fuse Catalog Numbers * Open fuse indication available by inserting the sufix ID. E.g., FRS-R-15ID. Fuse Clips (Case) Size (Pairs) 600V 60A 30A NO.663-R Carton Quantity and Weight 30A NO.216-R Amp Rating Carton Qty. 100A 1 60A NO.616-R 1015 10 1 200A 60A NO.626-R 17 230 10 35-60 10 For additional information on Class R fuse reducers, see Data Sheet 1118. 0713 BU-SB13728 Page 1 of 3 Data Sheet 1017FUSETRON 600V Class RK5 1 FRS-R 600Vac/300Vdc, 10-60A, Dual Element, Time-Delay Fuses Time-Current Curves - Average Melt 1 10 to 8 Amps AMP RATING CURRENT IN AMPS 0713 BU-SB13728 Page 2 of 3 Data Sheet 1017 TIME IN SECONDS