BUSSMANN Effective December, 2015 Technical Data 2032 Supersedes May, 2002 SERIES GLR and HLR Non-rejecting, fast-acting fuse and inline fuse holders Catalog symbols: GLR (Fuse) HLR-2A and HLR-2L fuse holders HLR (Fuse holder) UL Recognized, 15A, 300Vac, Guide IZLT2, File E14853 Description: CSA Certified, 15A, 300Vac, Class 6225-01, Fast-acting, non-rejection style inline fuse and File 47235 fuse holder system A fuseholder Specifications: CSA Certified, 10A, 300Vac, Class 6225-01, Ratings File 47235 Volts GLR fuse catalog numbers 300Vac or less Fuse (amps) Amps GLR-3/16 GLR-1-6/10 GLR-5 GLR-9 3/16-15A GLR-1/2 GLR-2 GLR-6 GLR-10 Interrupting rating GLR-1 GLR-3 GLR-7 GLR-12 GLR-1-1/2 GLR-4 GLR-8 GLR-15* 10kA * Must be used with the HLR-2A holder rated to 15A. Agency information HLR fuse holder catalog numbers GLR fuse Catalog No. Description UL Listed, Std. 248-14, 3/16-15A/300Vac, Guide JDYX, File E19180 Holder with installed linseide HLR terminal wire for 3/16 to 12 amp CSA Cer tified, C22.2 No. 248.14, 0-10A/300Vac, GLR fuses Class 1422-01, File 53787 Holder with installed lineside and HLR-2A loadside terminal wires for 3/16 to HLR fuse holder 15 amp GLR fuses Holder with uninstalled lineside UL R ecognized, 12A, 300Vac, Guide IZLT2, HLR-2L and loadside terminal wires for File E14853 3/16 to 15 amp GLR fuses CSA Cer tified, 12A, 300Vac, Class 6225-01, Holder without lineside or loadside A termianl wires for for 3/16 to 15 File 47235 amp GLR fuses Non-rejecting, fast-acting GLR fuse and HLR in-line fuse holders Technical Data 2032 Effective December 2015 Features: Dimensions - in (mm): GLR fuse and knob are an integral one-piece unit. There are GLR fuse no replacement knobs (caps) Units can be panel mounted with a separate steel clip. For knockout hole mounting (see dimensions), order catalog number BK/A-104. For the keyhole punch type hole mounting, 0.63 (15.9) order catalog number 6374 for panels 0.043 to 0.062 thick, HLR fuse holder or catalog number 4909 for panels 0.030 to 0.042 thick. 2.250 (57.1) The HLR holder comes with 6 inches of red 18 insulated solid 0.850 (21.6) 0.720 (18.3) copper wire attached to the lineside terminal, customer inserts a 18 insulated solid copper wire into loadside terminal Lineside terminal lead Order holder catalog number HLR-2A to obtain 6 inches of C 0.850 21.6) L black 18 insulated solid copper wire pre-installed in the loadside terminal Order catalog number HLR-2L to obtain 6 inches of black 18 insulated solid copper wire packaged loose (uninstalled) Loadside terminal lead Mounting holes An alternative to the HLR fuse holder is the A fuse holder. 0.870 (22.1) 0.255 (6.5) The A fuse holder comes WITHOUT leads. The customer inserts 18 insulated solid copper wire into the lineside and the loadside terminals. The A fuse holder has the same body 0.635 (16.1) dimensions, utilizes the same mounting hole, and takes the 0.740 18.8) same mounting clips as the HLR, HLR-2A and HLR-2L 0.410 (10.4) Do not put tension on the fuse holders lineside terminal Knockout hole Keyhole punch 2 Eaton.com/bussmannseries