Effective August 2017 Technical Data 2031 Supersedes June 2016 GMF and GRF(fuse) HLR (fuse holder) Non-rejecting, time- delay fuse and in-line fuse holders GMF, GRF Catalog symbol: GMF, GRF (fuse) HLR (fuse holder) Ampere Rating: GMF 3/10 - 6 1/4 A, GRF 7 - 10 A Voltage Rating: 300 Volts AC or less Interrupting Rating: 10,000 A Agency information Fuse HLR UL Listed, Std. 248-14, Guide JDYX, File E19180 CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787 CE Fuse holder Product features HLR UL Recognized, 12A, 300 Vac, Guide IZLT2, File E14853 HLR carrier comes with 6 of 18 red insulated solid CSA Certified, 12A, 300 Vac, Class 6225-01, File 47235 copper wire attached to the line side CE Customer inserts a 18 insulated solid copper wire into HLR-2 and HRL-2L load side receptacle UL Recognized, 15A, 300 Vac, Guide IZLT2, File E14853 Order part number HLR-2 to obtain 6 CSA Certified, 15A, 300 Vac, Class 6225-01, File 47235 of 18 black insulated solid copper wire pre-installed in a CE load side receptacle Order part number HLR-2L to obtain 6 of 18 black insulated solid copper wire packaged loose Catalog numbers (un-installed) An alternative to the HLR fuseholder is Fuse Holder Fuse Holder the A fuseholder. The A fuseholder comes WITHOUT GMF-3/10 HLR GMF-3 HLR leads. The customer inserts 18 insulated solid copper GMF-1/2 HLR GMF-3 2/10 HLR wire into the line side receptacle as well as into the load GMF-6/10 HLR GMF-4 HLR side receptacle. It has the same body dimensions, utilizes GMF-8/10 HLR GMF-5 HLR the same mounting hole, and takes the same mounting GMF-1 HLR GMF-6 1/4 HLR clips as the HLR. The A fuseholder is UL Recognized, 10A, GMF-1 1/4 HLR GRF-7 HLR 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235 GMF-1 6/10 HLR GRF-8 HLR Fuse and knob are an integral one-piece unit. There are no GMF-2 HLR GRF-10 HLR replacement knobs (caps) GMF-2 1/2 HLR GMF-10 HLR Units can be panel mounted with a separate steel clip. For GMF-2 8/10 HLR the knockout hole (see above), choose BK/A-104. For the keyhole punch type hole, choose 6374 for panels 0.043 to 0.062 thick, or 4909 for panels 0.030 to 0.042 thick Do not put tension on line (rear) terminal of fuseholderGMF and GRF(fuse) HLR (fuse holder) Technical Data 2031 Non-rejecting, time-delay fuse and in-line fuse holders Effective August 2017 Time-current curvesaverage melt Time-current curvesaverage melt Amp Amp rating rating 100 100 10 10 1 1 .1 0.1 0.01 0.01 RMS symmetrical current in amps RMS symmetrical current in amps Dimensions - in (mm): Fuse 0.63 (15.9mm) Fuse and carrier 2.250 (57.15mm) 0.850 (21.59mm) Line lead 0.850 C L (21.59mm) 0.720 (18.29mm) Load lead Mounting hole 0.410 (10.41mm) 0.870 (22.10mm) 0.635 (16.13mm) 0.740 0.255 (18.80mm) (6.48mm) Knockout hole Keyhole punch Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Eaton Electronics Division 1000 Eaton Boulevard Cleveland, OH 44122 United States www.eaton.com/electronics 2017 Eaton Eaton is a registered trademark. All Rights Reserved Printed in USA All other trademarks are property Publication No. 2031 SB02233 of their respective owners. August 2017 0.1 Time in seconds 0.3 0.5 1 1 1.6 2 3 3.2 4 10 100 200 Time in seconds 0.1 1 5 10 7 8 10 100 200