BUSSMANN Effective January 2016 Technical Data 2130 Supersedes September 2012 SERIES HEZ breakaway and non-breakaway in-line rejection fuse holders for UL Class CC fuses Use these part numbers to order insulating boots for a non-breakaway HEZ holder: Description Part no. Single conductor 2A0660 Dual conductor 2A0661 Catalog Symbol: HEZ Boot reference: Description: Bussmann series HEZ submersible, single-pole in-line rejection fuse holders are for UL Class CC 0.8 4.1 fuses. They are available in non-breakaway and (20) (104) breakaway versions with an array of terminal options to meet application needs. Breakaway versions come with insulating boots to provide submersibility per UL IP67. Non-breakaway versions require ordering optional insulating boots 1.3 4.7 (33) for submersibility. (119) Recommended fuses: Installation instructions: Strip wire insulation equal to the depth of the Catalog symbol Operation Data sheet No. crimp or screw terminal. Torque screw terminal LP-CC 1023 to 35 Lb-In (3.9 Nm) or crimp terminal twice, Time-delay FNQ-R 1014 spacing crimps a distance of one-third from each end (as shown below) using an appropriate KTK-R Fast-acting 1015 crimp tool and die. See page 3 for recommended Ratings: crimping tools. Volts: 600V Crimp terminal twice at locations 1/3 distance Amps: up to 30A limited by conductor size from each end Withstand: 200kA RMS Sym. Agency information: UL Listed, Guide IZLT, File E14853 CSA Certified, Class 6225-01, File 47235 Strip wire insulation to depth of terminal CE, RoHS compliant Related products: Coupling nut torque: 10-20 Lb-In (1.1-2.2 Nm) Catalog Data no. Description sheet no. Operating and storage temperature: Two-pole supplemental in-line HEX 2126 -40F (-40C) to 221F (105C) fuse holder Insulating boots: One-pole supplemental in-line HEB 2127 fuse holder Two insulating boots come standard with the Two-pole Class CC in-line breakaway holder configurations. Insulating boots HEY 2126 fuse holder are not included as standard with non-breakaway One-pole in-line, permanently holders. Two insulating boots must be ordered HET 2125 installed neutral separately, if required, for each non-breakaway Class CC neutral dummy link holder ordered. When insulating boots are utilized, NNB-R (not a fuse) extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current.Technical Data 2130 Bussmann series HEZ breakaway and non-breakaway Effective January 2016 in-line rejection fuse holders for UL Class CC fuses Non-breakaway catalog number system To order: Specify catalog symbol HEZ and the loadside terminal code. Then select a lineside HEZ - A A terminal code that is available with the loadside terminal. Example: HEZ-AA defines a non-breakaway holder with both loadside and lineside copper crimp terminals for a single 8-16 AWG or two 12-16 AWG wires. Agency Information Loadside terminal Lineside terminal Reference Wire Wire length Breakaway UL CSA Terminal type range* Terminal type range* A equivalent 8-16 8-16 X X Cu crimp Cu crimp 4.4 (112) HEZ-AW-RLC-A HEZ A A (2) 12-16 (2) 12-16 * Solid/stranded conductors unless otherwise noted. Non-breakaway terminal data Conductor data Terminal type Cu crimp 8-16 1 A 10-16 2 Non-breakaway dimensions - in (mm): A 9.125 (232) Assembled length 2 Eaton.com/bussmannseries Catalog symbol Loadside terminal Lineside terminal Size No. per terminal Solid Stranded Catalog symbol Load /Line