Bussmann Specialty Fuse GMF, GRF Time-Delay, Non-Rejecting & HLR Dimensional Data FUSE 0.63 (15.9mm) FUSE AND CARRIER 57.15 2.250 21.59 Catalog Symbols: GMF and GRF 18.29 .850 .720 Time-Delay Non-Rejection Style Fuse 21.59 C GMF GRF L .850 Amperes -6 7-10 Volts AC 300 125 6.48 22.10 MOUNTING HOLE .255 .870 Interrupting Rating: 10,000 Amperes Agency Approvals: 16.13 18.80 .635 GMF and GRF Fuse: .740 U.L. Listed, Std. 248-14, Guide JDYX, File E14853 10.41 CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787 .410 Knockout Hole Keyhole Punch HLR Fuseholder: U.L. Recognized, 12A, 300 Vac, Guide IZLT2, File E14853 CSA Certified, 12A, 300 Vac, Class 6225-01, File 47235 HLR-2A: U.L. Recognized, 15A, 300 Vac, Guide IZLT2, File E14853 General Information: CSA Certified, 15A, 300 Vac, Class 6225-01, File 47235 HLR carrier comes with 6 of 18 red insulated solid copper wire attached to the line side. Electrical Ratings for Type GMF and GRF Fuses and Non-Rejection Style Carriers Customer inserts a 18 insulated solid copper wire into load Fuse Carrier Fuse Carrier side receptacle. GMF- HLR GMF-2 HLR Order part number HLR-2A to obtain 6 of 18 black insulat- GMF- HLR GMF-3 HLR ed solid copper wire pre-installed in a load side receptacle. GMF- HLR GMF-3 HLR Order part number HLR-2L to obtain 6 of 18 black insulated GMF- HLR GMF-4 HLR solid copper wire packaged loose (un-installed). GMF-1 HLR GMF-5* HLR Fuse and knob are an integral one-piece unit. There are no GMF-1 HLR GMF-6* HLR replacement knobs (caps). GMF-1 HLR GRF-7** HLR Units can be panel-mounted with a separate steel clip GMF-2 HLR GRF-8** HLR (BK/A-104). GMF-2 HLR GRF-10** HLR *300 Volts AC. **125 Volts AC. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. Form No. GMF, GRF 12-23-98 Page 1 of 2 rev. 8/4/98 BIF Doc 2031 Rev. A Bussmann Specialty Fuse GMF, GRF Time-Delay, Non-Rejecting & HLR Time-Current Characteristic CurvesAverage Melt Time-Current Characteristic CurvesAverage Melt AMPERE AMPERE RATING RATING 100 100 10 10 1 1 .1 .1 .01 .01 CURRENT IN AMPERES CURRENT IN AMPERES The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con- tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Form No. GMF, GRF 12-23-98 Page 2 of 2 BIF Doc 2031 rev. 8/4/98 Rev. A TIME IN SECONDS .1 .2 .3 .5 1 1 1.6 2 3 3.2 4 10 100 200 TIME IN SECONDS .1 1 5 7 10 8 10 100 200