Electronic fuses Electronic PCB and small dimension fuses 4 Contents Description Page 5 x 15mm fuses 4-2 5 x 20mm IEC fuses . 4-3 5 x 20mm UL fuses 4-5 1/4 x 5/8 to 1 fuses .4-6 1/4 x 1 1/4 fast-acting fuses .4-7 1/4 x 1 1/4 time-delay fuses .4-8 PCB mount fuse holders 4-9 PCB fuseclips for 5mm dia. fuses . 4-11 PCB fuseclips for 1/4 dia. fuses 4-12 PCB fuseclips for 9/32, 13/32 and 9/16 dia. fuses 4-14 4-1 BUSSMANN SERIES FULL LINE CATALOG 1007July 2015 Eaton.com/bussmannseriesElectronic PCB and small dimension fuses 4 5 x 15mm fuses C515 (axial leads) C518 (axial leads) C517 (axial leads) C519 C520 Specifications Description: Fast-acting Specifications Specifications fuse. Description: Description: Construction: Glass tube. Time-delay fuse. Fast-acting fuse. Ratings: Dimensions: Dimensions: Volts 350Vac* 5 x 15mm 5 x 15mm 32Vdc (self (0.197 X 0.591). (0.197 X 0.591). certified) Construction: Construction: Amps 3A Glass tube. Glass tube. IR 100A 350Vac Ratings: Ratings: 100A Volts 125Vac (3.5- Volts 250Vac 250Vac 7A) 32Vdc (self 10kA 250Vac certified) 125Vac (125mA-3A) Amps 100mA-5A *350Vac/100A IR is UL Recognized 32Vdc (self certified) IR 35A (100mA-750mA Agency information: CE, UL Listing Amps 125mA-7A 250Vac) File E19180, Guide JDYX, CSA IR 25A (350mA 600Vac) 10kA (100mA-5A 125Vac) Certification File 53787, Class 35A (125mA-1A 250Vac) 100A (1.5-3.5A 250Vac) 1422-01, UL Recognized, File E19180, Guide JDYX2. 100A (1.25-3A 250Vac) 200A (4-5A 250Vac) Small footprint saves space in 400A (3.5-7A 125Vac) Agency information: CE, equipment. UL Recognized File E19180, Guide 10kA (125mA-3A 125Vac) Fast-acting for maximum component JDYX2CSA Certification File 53787, Agency information: CE, UL Listed protection. Class 1422-01. File E19180, Guide JDYX 350Vac rating for 277V ballast circuit 125mA-250mA and 375mA-3A, UL Features and benefits protection. Recognized, File E19180, Guide Small footprint saves space in JDYX2, 350mA and 3.5A-7A, CSA equipment. Typical applications Certification File 53787, Class Fast-acting for maximum component Electronic circuits 1422-01, 125mA-250mA and protection. Printed circuit boards 375mA-3A. Available in ferrule and axial leaded Electronic ballast protection configurations Features and benefits Catalog number (amps) Time-delay for closer sizing on With axial leads Typical applications inductive circuits. C517-3-R Electronic circuits Typical application Printed circuit boards Electronic circuits Catalog numbers (amps) Printed circuit boards With axial leads C518-100-R C518-750-R C518-4-R Catalog numbers (amps) C518-125-R C518-2-R C518-5-R With axial leads C518-250-R C518-2.5-R C515-125-R C515-800-R C515-2.5-R C518-375-R C518-3-R C515-250-R C515-1-R C515-3-R C518-500-R C518-3.5-R C515-350-R C515-1.25-R C515-3.5-R Without axial leads C515-375-R C515-1.5-R C515-4-R C520-100-R C520-750-R C520-3.5-R C515-500-R C515-1.6-R C515-5-R C520-125-R C520-1.5-R C520-4-R C515-600-R C515-2-R C515-6-R C520-250-R C520-2-R C520-5-R C515-750-R C515-2.25-R C515-7-R C520-375-R C520-2.5-R Without axial leads C520-500-R C520-3-R C519-125-R C519-750-R C519-2.25-R C519-250-R C519-1-R C519-2.5-R C519-350-R C519-1.25-R C519-3-R C519-375-R C519-1.5-R C519-3.5-R C519-500-R C519-1.6-R C519-4-R C519-600-R C519-2-R C519-5-R Data Sheet: 2006 (C515) and Data Sheet: 2026 (C518) and Data Sheet: 2025 2007 (C519) 2027 (C520) 4-2 BUSSMANN SERIES FULL LINE CATALOG 1007July 2015 Eaton.com/bussmannseries