Bussmann Buss High Voltage Fuses HV 1000 - 10,000 Volts Series HVA (1000 Volts) Length *Wt./100 Amps Dia. In. mm Lbs. Kg 1/16 3/4 1/8 1 1/4 1-1/2 1/10 2 0.41 3 76.1 2 0.91 2/10 3 3/10 4 3/8 6 1/2 10 HVB (2500 Volts) CATALOG SYMBOL: HVA, HVB, HVJ, HVL, HVR, HVT, HVU, 1/2 1-1/2 HVW, AND HVX 3/4 2 0.41 4.5 114.2 3 1.36 NON-TIME DELAY 13 HVJ (5000 Volts) 1000 TO 10,000 VOLTS 1/16 1-1/2 1/8 2 13/32 and 13/16 x Length 1/4 4 0.81 5 126.9 9 4.08 1/2 6 (10.3mm and 20.6mm x Length) 3/4 10 For High Voltage Circuits 1 HVL (10,000 Volts) Non-Time Delay fuses for high voltage instruments and cir- 1/16 1 cuits. 1/8 1-1/2 Physical size varies with electical rating of fuse to prevent 0.81 10 253.8 15 6.80 1/4 2 over-fusing. 1/2 3 Use HVA, HVB, HVJ an d HVL for circuits up to 20kw dc or HVR (1000 Volts) (max. S.C. KVA-500) 30 KVA ac. For higher interrupting capacity, use HVR, HVT, 1/2 3 HVU, HVW and HVX. 14 0.41 3 76.1 3 1.36 25 HVT (2500 Volts) (max. S.C. KVA-1250) Test Spectifications 1/2 3 Catalog 15 0.41 4.5 114.2 4 1.81 Number Load Opening Time 2 HVA HVU (5000 Volts) (max. S.C. KVA-2500) HVB 110% 4 Hours (min.) 1/2 3 HVJ 135% 1 Hour (max.) 14 0.81 5 126.9 19 8.62 HVL 25 HVR HVW (1200 Volts) (max. S.C. KVA-5000) HVT 100% 4 Hours (min.) 1/2 3 HVU 150% 1 Hour (max.) 14 0.41 2.25 57.1 2 0.91 HVW 25 HVX 8 HVX (10,000 Volts) (max. S.C. KVA-12,000) 1/2 3 0.41 10.0 253.8 36 16.33 15 *Shipping. Carton quantity: 10. Form No. HV Series 12-21-98 Page 1 of 2 SB98107 Rev. A BIF Doc 6003 Bussmann Buss High Voltage Fuses HV 1000 - 10,000 Volts Series Time-Current Characteristic CurvesAverage Melt AMPERE RATING 300 100 CATALOG SYMBOL: 4528, 4529, 4530, AND 2960 FUSE BLOCKS 10 For BUSS High Voltage Fuses (1000 to 10,000 Volts) Bakelite base. Alloy plated terminals. 1 Dimensional Data B .1 C A *Dimensions For Bock Inches/(mms) Fuse Cat. Base .01 Sym. No. A B C Width HVA 3.75 1.125 0.38 1.0 4528 HVR (95.3) (28.6) (9.5) (25.4) CURRENT IN AMPERES HVB 5.25 1.125 0.38 1.0 4529 HVT (133.4) (28.6) (9.5) (25.4) HVJ 6.5 1.66 0.5 1.38 4530 HVU (165.1) (42.1) (12.7) (34.9) HVL 11.44 1.45 0.75 1.38 2960 HVX (290.5) (48.4) (19.1) (34.9) *Two mounting holes: Use 8 screws on blocks 4528 and 4529. Use 10 screws on blocks 4530 and 2960. The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select- ed, it should be tested by the user in all possible applications. Form No. HV Series 12-21-98 Page 2 of 2 BIF Doc 6003 SB98107 Rev. A TIME IN SECONDS .02 1/16 .1 1/4 1/2 1 3/4 1 2 3 10 20