Effective August 2018 Technical Data 1007 Supersedes February 2016 Low-Peak LPJ Class J 600Vac/300Vdc, 70-600A, dual element, time-delay fuses Catalog numbers (amps) - non-indicating fuses* LPJ-70SP LPJ-125SP LPJ-250SP LPJ-500SP LPJ-80SP LPJ-150SP LPJ-300SP LPJ-600SP LPJ-90SP LPJ-175SP LPJ-350SP LPJ-100SP LPJ-200SP LPJ-400SP LPJ-110SP LPJ-225SP LPJ-450SP * Open fuse indication available on all part numbers by inserting the suffix I, e.g., LPJ-90SPI. Requires 75Vac minimum voltage. Indicating fuses are not Vdc rated. Available with easyID open fuse indication Carton Quantity: Amp rating Carton qty. 70200 5 225600 1 Catalog symbols: LPJ-(amp)SP (non-indicating) Dimensions - in: LPJ-(amp)SPI (indicating) 4.63 7.13 3.63 5.25 1.13 2.63 0.75 3.38 0.41 1.63 *2 Description: 1 0.28 0.38 0.13 0.53 1.88 0.25 65 to 100A 225 to 400A Bussmann series Ultimate protection LPJ Class 8.0 J dual element, current-limiting, time-delay fuses 5.75 6.0 4.38 3.75 0.53 available with optional open fuse indication. Time- 1.13 3.0 0.28 2 2.5 delay 10 seconds (minimum) at 500% of rated 1.5 current. 0.38 1.38 0.19 0.69 2.13 0.38 110 to 200A 450 to 600A Features: Specifications: Industrys only UL Listed and CSA Certified fuse Ratings with a 300kA interrupting rating that allows for Volts simple, worry-free installation in virtually any application. 600Vac Fast short-circuit protection and dual-element, 300Vdc* time-delay performance provide ultimate Amps 70-600A protection. Reduces existing fuse inventory by up to 33% IR when upgrading to Low-Peak fuses. 300kA Vac RMS Sym. Consistent 2:1 ampacity ratios for all Low-Peak 100kA Vdc fuses make selective coordination easy. Long time-delay minimizes needless fuse openings * Indicating versions not Vdc rated. due to temporary overloads and transient surges. Agency information Current-limitation protects downstream UL Listed, Guide JDDZ, File E4273 components against damaging thermal and magnetic effects of short-circuit currents. CSA Certified, Class 1422-02, File 53787, Dual-element fuses have lower resistance than Class J per CSA C22.2 No. 248.8 ordinary fuses so they run cooler. CE Can often be sized for back-up protection against RoHS compliant motor burnout from overload or single-phasing if other overload protective devices fail. Proper sizing can provide no damage Type 2 coordinated protection for NEMA and IEC motor controllers. Space-saving package for equipment downsizing.Technical Data 1007 Low-Peak LPJ Class J 600Vac/300Vdc, 70-600A, Effective August 2018 dual element, time-delay fuses Recommended fuse blocks: Time-current curves - average melt: Fuse amps 1-Pole 2-Pole 3-Pole 70-100 JM60100-1CR JM60100-2CR JM60100-3CR 110-200 JM60200-1CR JM60200-2CR JM60200-3CR AMP RATING 300 225-400 JM60400-1CR JM60400-2CR JM60400-3CR 450-600 JM60600-1CR JM60600-2CR JM60600-3CR 200 For additional information on the JM fuse blocks, see product brochure no. 3192. 100 Fuse reducers for Class J fuses: Desired fuse Catalog numbers Equipment fuse clips (case) size (pairs) 30A J-13 100A 60A J-16 60A J-26 200A 100A J-21 100A J-41 400A 200A J-42 10 200A J-62 600A 400A J-64 Not for bolt-in applications. 1 0.1 0.01 CURRENT IN AMPS 2 Eaton.com/bussmannseries TIME IN SECONDS 100 80A 100A 125A 200A 250A 400A 1000 600A 10,000