Effective June 2017 Technical Data 1030 Supersedes July 2013 250 V NON/600 V NOS Class K5 and H fuses Catalog numbers (amps) NON-1/8 NON-3 NON-12 NON-65 NON-200 NON-1/2 NON-3-2/10 NON-15 NON-70 NON-225 NON-3/4 NON-4 NON-20 NON-75 NON-250 NON-8/10 NON-5 NON-25 NON-80 NON-300 NON-1 NON-6 NON-30 NON-90 NON-350 NON-1-1/4 NON-6-1/4 NON-35 NON-100 NON-400 NON-1-1/2 NON-7 NON-40 NON-110 NON-450 NON-1-6/10 NON-8 NON-45 NON-125 NON-500 NON-2 NON-9 NON-50 NON-150 NON-600 NON-2-1/2 NON-10 NON-60 NON-175 Carton quantity Amps Qty. 1/8-60 10 65100 5 110600 1 Description Dimensions in Basic protection 250V NON Class K5 and H All Diameters 0.008 10.38 ( 0.094) general purpose, non-current-limiting, one-time 2 (0.031) fuses. 0.56 ( 0.008) 2.59 Catalog symbol 1/8 to 30A 450 to 600A NON-(amp) 3 8.63 ( 0.094) Ratings (0.031) 0.81 ( 0.008) 2.06 Volts 35 to 60A 250 Vac 225 to 400A 125 Vdc (1/8-100 A) 5.88 ( 0.062) 7.13 ( 0.062) Amps 1/8-600 A 1.06 1.56 IR 110 to 200A 65 to 100A Features 50 kA Vac RMS Sym. (1/8-60 A) 10 kA Vac RMS Sym. (65-600 A) Protect lighting, heating and other circuits not subject to temporary surges and where 50 kA Vdc (1/8-60 A) available short-circuit currents are relatively low 10 kA Vdc (65-100 A) NON one-time fuses do not have any Agency information appreciable degree of timedelay and thus should not be specified in circuits where UL Listed, Class K5 (1/8-60 A), Std. 248-9, Class large transients or motor overloads occur. H (65-600 A), Std. 248-6 (125 Vdc 1/8-100 A), UL Use Bussmann series advanced protection Guide JDDZ, File E4273 FUSETRON FRN-R or ultimate protection CSA Certified, Class 1421-01, File 53787 (1/8-12 Low-Peak LPN-RK dual-element, time-delay A, 65-600 A) fuses. CE For general purpose circuits, size at amp rating of circuit For CSA Certified 15-60 A, see PON data sheet no. 4126. For motor circuits, size at 300% to 400% according to the NEC motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)Technical Data 1030 250 V NON/600 V NOS Class K5 and H fuses Effective June 2017 Recommended fuse blocks NON time-current curves average melt 1-, 2- and 3-pole modular fuse blocks up to 600 amps see data sheet no. 10487 AMP RATING 1-, 2- and 3-pole modular power distribution fuse blocks up to 60 300 amps see data sheet no. 10490 Fuse reducers for Class R fuses 100 Desired fuse (case) Catalog no. (pairs) Equipment fuse clips size 250V 60 A 30 A NO.263 30 A NO.213 100 A 60 A NO.216 60 A NO.226 200 A 100 A NO.2621 100 A NO.2641 400 A 10 200 A NO.2642 100 A NO.2661 600 A 200 A NO.2662 400 A NO.2664 Not CSA certified. For additional information on Class K5 & H fuse reducers, see data sheet no. 1118. 1 0.1 0.01 CURRENT IN AMPS 2 Eaton.com/bussmannseries TIME IN SECONDS 20 15A 20A 30A 35A 60A 100 100A 200A 400A 600A 1000 10,000