Bussmann One-Time General Purpose Fuses NON and NOS 250 and 600 Volts, to 600 Amps Dimensions All diameters ( 0.008) 5 (600V) 2 (250V) ( 0.031) ( 0.031) 0.81 ( 0.008) .56 ( 0.008) to 30A to 30A 5.5 (600V) 3 (250V) ( 0.031) ( 0.031) 1.06 ( 0.008) .81 ( 0.008) 35A to 60A 35A to 60A 7.13 (250V) ( 0.062) 5.88 (250V) ( 0.062) 9.63 (600V) ( 0.062) 7.9 (600V) ( 0.062) Catalog Symbol: NON (250V) NOS (600V) 1.56 (250V) 1.06 (250V) For general purpose application 1.84 (600V) 1.34 (600V) Ampere Rating: to 600A 110A to 200A 70A to 100A Voltage Rating: NON: 250Vac, 125Vdc (0-100A) NOS: 600Vac 8.63 (250V) ( 0.094) 10.38 (250V) ( 0.094) 11.63 (600V) ( 0.094) 13.38 (600V) ( 0.094) Non-Current-Limiting 2.59 (250V) Interrupting Rating: 50,000A RMS Sym. (0-60A), 2.06 (250V) 3.13 (600V) 2.59 (600V) 10,000A RMS Sym. (65-600A), 50,000A 125Vdc (NON 0-60), 10,000A 125Vdc (NON 65-100A) 225A to 400A 450A to 600A Agency Information: UL Listed - 250V: Class K5 (0-60A), Std. 248-9 General Information: Class H (65-600A), Std. 248-6 Protect lighting, heating and other circuits not subject to tem- (125Vdc: NON 0-100) porary surges and where available short-circuit currents are 600V: Class K5 (0-60A), Std. 248-9 relatively low. Class H (70-600A), Std. 248-6 UL Guide JDDZ, File E4274 ONE-TIME fuses do not have any appreciable degree of time- CSA Certified, Class 1421-01, File 53787 (0-12 & 65-600A) 250V delay and thus should not be specified in circuits where large (0-600A) 600V transients or motor overloads occur. Use Buss FUSETRON Catalog NumbersNON ONE-TIME (250Vac) or LOW-PEAK dual-element, time-delay fuses. NON- NON-5 NON-40 NON-175 For general purpose circuits, size at ampere rating of circuit. NON- NON-6 NON-45 NON-200 For motor circuits, size at 300% to 400%. NON- NON-6 NON-50 NON-225 Catalog NumbersNOS ONE-TIME (600Vac) NON- NON-7 NON-60 NON-250 NOS-1 NOS-12 NOS-70 NOS-225 NON-1 NON-8 NON-65 NON-300 NOS-2 NOS-15 NOS-75 NOS-250 NON-1 NON-9 NON-70 NON-350 NOS-3 NOS-20 NOS-80 NON-300 NON-1 NON-10 NON-75 NON-400 NOS-4 NOS-25 NOS-90 NOS-350 NON-1 NON-12 NON-80 NON-450 NOS-5 NOS-30 NOS-100 NOS-400 NON-2 NON-15 NON-90 NON-500 NOS-6 NOS-35 NOS-110 NOS-450 NON-2 NON-20 NON-100 NON-600 NOS-7 NOS-40 NOS-125 NOS-500 NON-3 NON-25 NON-110 NOS-8 NOS-45 NOS-150 NOS-600 NON-3 NON-30 NON-125 NOS-9 NOS-50 NOS-175 NON-4 NON-35 NON-150 NOS-10 NOS-60 Carton Quantity and WeightNON ONE-TIME (250Vac) Weight** Catalog Carton Number Qty. Lbs. Kg. NON 30 10 0.38 0.172 Carton Quantity and WeightNOS ONE-TIME (600Vac) NON 3560 10 1.00 0.453 Weight** Catalog Carton NON 65100 5 0.79 0.358 Number Qty. Lbs. Kg. NON 110200 1 0.79 0.358 NOS 130 10 1.45 0.657 NON 225400 1 1.65 0.748 NOS 3560 10 2.6 1.179 NON 450600 1 2.76 1.251 NOS 70100 5 2.80 1.270 NON -(1/8-60) is rated at 125Vdc with 50,000 AIC Rating. NOS 110200 1 1.24 0.562 NON -(65-100) is rated at 125Vdc with 10,000 AIC Rating. NOS 225400 1 3.03 1.374 **Weight per carton. NOS 450600 1 4.63 2.100 For CSA Certified 15-60A Ratings, see PON Data Sheet: 4126 Weight per carton. ** Recommended fuseblocks for CE logo denotes compliance with European Union Low Voltage Directive Class H & K5, 250V & 600V fuses (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. See Data Sheets: 1112 (250V) and Applies to OPM-1038 and OPM-1038R. 1113 (600V) Form No. NON/ NOS Page 1 of 2 10-2-02 SB02295 Data Sheet: 1030 Bussmann One-Time General Purpose Fuses NON and NOS 250 and 600 Volts, to 600 Amps Time-Current Characteristic CurvesAverage Melt NON ONE-TIME (250Vac) NOS ONE-TIME (600Vac) AMPERE AMPERE RATING RATING 300 300 100 100 10 10 1 1 .1 .1 .08 .06 .04 .03 .02 .01 .01 CURRENT IN AMPERES CURRENT IN AMPERES The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con- tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Form No. NON/NOS Page 2 of 2 10-2-02 SB02295 Data Sheet: 1030 TIME IN SECONDS 20 15A 20A 30A 35A 60A 100 100A 200A 400A 600A 1,000 10,000 TIME IN SECONDS 20 15A 20A 30A 35A 60A 100 100A 200A 400A 600A 1,000 10,000