Mainswitch,3pole+1N/O+1N/C,63A,Emergency-Stopfunction, Lockableinthe0(Off)position,surfacemounting Partno. P3-63/I4/SVB/HI11 Articleno. 207348 Deliveryprogramme Product range Main switch maintenance switch Repair switch Part group reference P3 STOPP-Funktion Emergency switching off function With red rotary handle and yellow locking ring Information about equipment supplied Auxiliary contact or neutral conductor fitted by user. Number of poles 3 pole Auxiliarycontacts N/O 1 N/C 1 Locking facility Lockable in the 0 (Off) position Degree of Protection IP65 Design surface mounting Contact sequence Function MotorratingAC-23A,50-60Hz 400 V P kW 30 Rated uninterrupted current I A 63 u Technicaldata General Standards IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnector according to IEC/EN 60947-3 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Enclosed C -25 - +40 03/18/2016 207348 - HPL-ED2016 V20.0 EN 1 / 6Overvoltage category/pollution degree III/3 Rated impulse withstand voltage U V AC 6000 imp Mechanical shock resistance g 15 Mounting position As required Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Contacts Mechanical variables Number of poles 3 pole Auxiliary contacts N/O 1 N/C 1 Electrical characteristics Rated operational voltage U V AC 690 e Rated uninterrupted current I A 63 u Note on rated uninterrupted current Rated uninterrupted current Iu is specified for max. cross-section. u Load rating with intermittent operation, class 12 AB 25 % DF x I 2 e AB 40 % DF x I 1.6 e AB 60 % DF x I 1.3 e Short-circuit rating Fuse A gG/gL 80 Rated short-time withstand current (1 s current) I A 1260 cw rms Note on rated short-time withstand current lcw Current for a time of 1 second Rated conditional short-circuit current Iq kA 4 Switchingcapacity cos rated making capacity as per IEC 60947-3 A 800 Rated breaking capacity cos to IEC 60947-3 A 230 V A 640 400/415 V A 600 500 V A 590 690 V A 340 Safe isolation to EN 61140 between the contacts V AC 440 Current heat loss per contact at I W 4.5 e Current heat loss per auxiliary circuit at I (AC-15/230 V) CO 0.2 e 6 Lifespan, mechanical Operations > 0.1 x 10 Maximum operating frequency Operations/h 1200 AC AC-3 Rating, motor load switch P kW 220 V 230 V P kW 15 400 V 415 V P kW 30 500 V P kW 30 690 V P kW 30 Rated operational current motor load switch 230 V I A 51 e 400V 415 V I A 55 e 500 V I A 44 e 690 V I A 22.1 e AC-21A Rated operational current switch 440 V I A 63 e AC-23A Motor rating AC-23A, 50 - 60 Hz P kW 03/18/2016 207348 - HPL-ED2016 V20.0 EN 2 / 6