Tripbloc kAdvanc ed1-4A Partno. PKE-XTUA-4 Articleno. 121728 Deliveryprogramme Accessories Trip blocks Setting range of overload releases I A 1 - 4 r Expansions With communication capability Function With overload release Rated uninterrupted current I A 4 u Motor rating AC-3 220 V 230 V P kW 0.75 380 V 400 V P kW 1.5 440 V P kW 1.5 500 V P kW 2.2 660 V 690 V P kW 3 For use with PKE12 basic device Motor output/rated motor current Motor AC-3 power rated motor current 220, 230 380, 400, 440 V 500 V 660, 690 V 240 V 415 V 0.18 1.04 0.25 1.4 0.37 2 1.1 1.02 0.55 2.7 1.5 1.39 1.2 0.75 3.2 1.9 1.68 1.5 1.1 1.1 2.6 2.41 2.1 1.5 1.5 3.6 3.28 2.9 2.1 2.2 4 2.9 3 3.8 Approvals Product Standards UL 508 CSA-C22.2 No. 14-10 IEC60947-4-1 CE marking UL File No. E36332 UL CCN NLRV CSA File No. 12528 CSA Class No. 3211-05 NA Certification UL listed, CSA certified Specially designed for NA No General Standards IEC/EN 60947, VDE 0660 Climatic proofing Damp heat, constant to IEC 60068-2-78 Damp heat, cyclic to IEC 60068-2-30 Ambient temperature C Storage C -40 - +80 Open C -20 - +55 Enclosed C -20 - +40 Mounting position Direction of incoming supply as required Degree of protection Device IP20 Terminations IP00 Protection against direct contact Finger and back-of-hand proof Mechanical shock resistance half-sinusoidal shock 10 ms to IEC g 25 60068-2-27 Altitude m 2000 06/25/2012 HPL-ED2012 V1.1 EN 1 / 42 Terminal capacity screw terminals mm 2 Solid 1 x (1 - 6) mm 2 x (1 - 6) 2 Flexible with ferrule to DIN 46228 1 x (1 - 6) mm 2 x (1 - 6) Solid or stranded AWG 18 - 10 Specified tightening torque for terminal screws Main cable Nm 1.7 Control circuit cables Nm 1 Mainconductingpaths Rated impulse withstand voltage U V 6000 imp AC Overvoltage category/pollution degree III/3 Rated operational voltage U V 690 e AC Rated uninterrupted current = rated operational current I = I A 4 u e Rated frequency f Hz 40 - 60 Lifespan, mechanical Operations x 0.05 6 10 Lifespan, electrical (AC-3 at 400 V) Operations x 0.05 6 10 Maximum operating frequency Ops./ h Max. operating frequency Ops/ 60 h Motor switching capacity kA rms AC-3 (up to 690 V) A 4 Tripbloc k s Temperature compensation C -5 40 (to IEC/EN 60947, VDE 0660) -25 55 (operating range) Temperature compensation residual error for T > 40 C 0.1%/K Setting range of overload releases 0.25 - 1 x I u Fixed short-circuit release Trip block 12 x I r delayed approx. 60 ms Short-circuit release tolerance 20% Phase-failure sensitivity yes Tec hnic aldataETIM4.0 Final value of non-delayed short-circuit release setting range A 48 Initial value of non-delayed short-circuit release setting range A 1 Setting range of overload releases A 4 Short-circuit release function Delayed Number of poles 3 Rated uninterrupted current Iu A 4 Characteristic s 06/25/2012 HPL-ED2012 V1.1 EN 2 / 4