Fast-Acting CUBEFuse Photovoltaic Applications Features and Product Benefits Maximize uptime and reliability using fuses designed and listed to UL 2579: Low Voltage Fuses- Fuses for 600Vdc Photovoltaic Systems Fast-acting protection specifically designed for low-fault current conditions that occur in PV systems Maximize return on investment with fuses proven to withstand harsh temperatures demonstrated performance in extreme temperature cycling conditions, ranging from -40C through 90C Minimize panel space by up to 70% with readily available Class CF holders Proven to clear faults faster than the UL requirement Catalog Symbol: PVCF RN Minimal energy consumption leading to increased efficiency Fast-Acting Fuse 6-minutes maximum clearing time at Ampacity rejecting holders help prevent overfusing 200% rated current for 30 to 60A fuse Finger-safe construction minimizes exposure to live parts, 8-minutes maximum clearing time at reducing hazard to personnel 200% rated current for 70 to 100A fuse Ratings: Volts 600Vdc CUBEFuse Holders Amps 35-100A Catalog Numbers IR 50kA DC (UL & CSA) (amps) Fits Fuse Holder Agency Information: Non-Indicating TCFH60N TCFH100N UL Listed Fuse: Guide JFGA, File E335324 PVCF35RN X X CSA component certified C22.2 PVCF40RN X X Other Ratings/Specifications: PVCF45RN X X PVCF50RN X X Watts Loss at rated current: PVCF35RN: 5.45W PVCF60RN X X PVCF60RN: 7.27W PVCF70RN X PVCF100RN: 11.50W PVCF80RN X Operating and Storage Temperature Range: -40 to 90C PVCF90RN X Material Specifications: PVCF100RN X Case: Glass filled PES (Polyethersulfone) Terminals: Copper alloy Terminal plating: Electroless tin CUBEFuse Holders Catalog Numbers (amp rating) Non-Indicating CUBEFuse PVCF35RN PVCF50RN PVCF80RN PVCF40RN PVCF60RN PVCF90RN PVCF45RN PVCF70RN PVCF100RN Carton Quantity and Weight Amp Carton Weight Per Carton Rating Qty. lbs kg All 100 and 60A CUBEFuse holders can dovetail together for PVCF-35-60A 12 1.42 0.65 the required number of poles with the smallest footprint PVCF-70-100A 6 1.74 0.79 possible compared to Class J solutions. See CUBEFuse holder Data Sheet 9007 1111 BU-SBXXXXX Page 1 of 2 Data Sheet 2155Fuse Dimensions - in (mm) PVCF RN Dimensions in (mm) Amps A B C D E F G 2.13 1.00 1.13 0.36 0.04 0.63 0.38 35-40 (54.10) (25.40) (28.58) (9.10) (1.02) (15.93) (9.65) 2.13 1.00 1.13 0.44 0.04 0.63 0.38 45-50 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 2.13 1.00 1.13 0.44 0.04 0.63 0.38 60 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 3.01 1.00 1.26 0.49 0.06 0.58 0.38 70 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 3.01 1.00 1.26 0.49 0.06 0.58 0.38 80-90 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 3.01 1.00 1.26 0.57 0.06 0.58 0.38 100 (76.45) (25.40) (32.00) (14.48) (1.60) (14.78) (9.65) Time-Current Characteristic CurvesAverage Melt Current Limitation Curves B 100,000 1000 100A 60A 10,000 50A 40A 35A 100 1,000 10 A 100 PROSPECTIVE SHORT CIRCUIT CURRENT SYMMETRICAL RMS AMPS 1 0.1 0.01 CURRENT IN AMPS 1111 BU-SBXXXXX Page 2 of 2 Data Sheet 2155 TIME IN SECONDS 1 10 35A 40A 50A 60A 100 100A 1,000 10,000 INSTANTANEOUS PEAK LET THRU CURRENT IN AMPS 100 1,000 10,000 100,000 300,000