Connectivity Solutions 9.1 SmartWire-DT Panel Wiring Solution SmartWire-DT 9 System Overview Product Description V7-T9-2 9 Features . V7-T9-2 9 System Overview Diagram . V7-T9-3 System Components 9 Product Description V7-T9-6 Product Selection V7-T9-7 9 Accessories . V7-T9-8 9 System Controllers Product Description V7-T9-11 9 Features . V7-T9-11 XV Series HMI-PLC Standards and Certifications V7-T9-11 9 with SmartWire-DT Contactor Modules 9 Product Description V7-T9-12 Features . V7-T9-12 9 Product Identification . V7-T9-13 Product Selection V7-T9-14 9 Pilot Device Modules 9 Product Description V7-T9-15 Features . V7-T9-15 9 Product Identification . V7-T9-16 Product Selection V7-T9-18 9 Technical Data and Specifications V7-T9-20 9 Dimensions . V7-T9-34 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Volume 7Logic Control, Operator Interface and Connectivity Solutions CA08100008EMarch 2012 www.eaton.com V7-T9-1Connectivity Solutions 9.1 SmartWire-DT Panel Wiring Solution Contents SmartWire-DT Panel Wiring Solution 9 Description Page SmartWire-DT Panel Wiring Solution 9 System Components V7-T9-6 9 System Controllers . V7-T9-11 Contactor Modules . V7-T9-12 9 Pilot Device Modules V7-T9-15 Technical Data and Specifications V7-T9-20 9 Dimensions . V7-T9-34 9 9 9 9 9 9 System Overview Product Description Features 9 Typical faults such as loose Nodes on the SmartWire-DT The SmartWire-DT system Connects directly to connections and miswired network are automatically uses a continuous green standard XTCE contactors, 9 terminations are eliminated assigned addresses on the flat cable located in the XTRE control relays, and using the flat cable and the gateway with the push of a control cabinet to connect M22 pilot devices 9 specialized connectors. buttonassigning addresses motor starters, pushbutton Supports EtherNet/IP, Furthermore, each in the order that the nodes actuators, and indicator lights. Modbus TCP, 9 SmartWire-DT enabled device are connected. The system It eliminates the need for PROFIBUS-DP and has individual diagnostic LEDs employs time monitoring most of the conventional CANopen fieldbuses built in, which reduce and a watchdog timeout 9 point-to-point control wiring Supports up to 99 nodes commissioning time and using the established and even integrates 24 Vdc on Ethernet and CANopen, troubleshooting in the field. target configuration as a control power for contactor 9 and 58 nodes on referencesafely monitoring coils on the eight conductor PROFIBUS-DP the integrity of the control flat cable. The start of the 9 Automatically assigns scheme. SmartWire-DT has SmartWire-DT system is a addresses to SmartWire-DT a maximum network length gatewayit establishes the nodes 9 of 2000 ft, can be extended connection to standard to pushbutton control stations Integrates and supplies programmable logic controller outside of the control cabinet, 24 Vdc power to contactor (PLC) fieldbuses, such as 9 and can connect up to and relay coils over the EtherNet/IP, Modbus TCP, 99 nodes per gateway. A network PROFIBUS-DP and CANopen. 9 software program called Because SmartWire-DT directly Includes diagnostic bi-color SWD-Assist enables the integrates the input/output LEDs on each node 9 layout, planning, and (I/O) level in the switching connection system configuration of a devices, no conventional PLC SmartWire-DT network. 9 I/O modules are needed instead communication enabled modules are attached 9 to standard Eaton motor control components. Thus, 9 the PLC in the control cabinet simply consists of a central 9 processing unit (CPU) module. 9 9 9 9 V7-T9-2 Volume 7Logic Control, Operator Interface and Connectivity Solutions CA08100008EMarch 2012 www.eaton.com