Low-Peak CUBEFuse Finger-Safe, Dual-Element, Time-Delay Class CF Fuse, 1-100A, 600Vac/300Vdc Features and Product Benefits The worlds first finger-safe power fuse system. Smallest footprint of any class fuse including Class J, CC, T and RK. Meets Class CF and Class J time-delay electrical performance requirements. Available with and without open fuse indication. The indicating version features easyID open fuse technology for faster troubleshooting and reduced downtime. Faster response to damaging faults to help reduce destructive thermal and magnetic forces. 70-100A Case Size 35-60A Case Size 1-30A Case Size True dual-element fuse construction with a minimum of 10 seconds time- delay at 500% of rating. Catalog Symbols: TCF Indicating fuse (6-100A) TCF RN Non-indicating fuse (1-100A) Long time-delay minimizes nuisance circuit openings due to temporary Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at overloads and transient surges. 500% Rated Current High interrupting rating to safely interrupt faults up to 300kA. Ratings: No venting of arc or molten metal and gases during opening. Volts 600Vac/300Vdc Robust cycling and inrush current withstand. Amps 1 to 100A Low let-through currents under fault conditions. IR 300kA RMS Sym. (UL) 200kA RMS Sym. (CSA) Provides Type 2 No Damage protection for IEC motors starters when 100kA DC (UL & CSA) properly sized. Agency Information: Easy selective coordination with any other Cooper Bussmann Low-Peak UL Listed Fuse: Guide JFHR, File E4273 Class CC, L, J and RK1 fuse with simple 2:1 amp ration between upstream CSA Certified Fuse: Class 1422- 02, File 53787 and downstream fuses. CE compliance for the European Union low voltage directive RoHS Compliant Other Ratings/Specifications: CUBEFuse Holders, Disconnects and Panelboards Watts Loss at rated current: TCF30: 3.99W The CUBEfuse is used in the following Cooper Bussmann products. TCF60: 6.23W TCF100: 9.51W Operating and Storage Temperature Range: -40 to 80C At 100, 60 & 30A CUBEFuse holders can be dovetail Material Specifications: together for the smallest footprint possible of any Case: Glass filled PES (Polyethersulfone) Class J fuse solution. See CUBEFuse holder Data Sheet 9007 Terminals: Copper alloy Terminal plating: Electroless tin Indicator lens: PES (Polyethersulfone) (indicating version only) Indicator: Energetic chemical Catalog Numbers (amp rating) Indicating CUBEFuse The DIN-Rail mounted 1-, 2- and 3-Pole CCP CF 1 comes in 30, 60 and 100A versions. TCF6 TCF10 TCF15 TCF17- /2 TCF20 TCF25 See Data Sheet 1157 TCF30 TCF35 TCF40 TCF45 TCF50 TCF60 TCF70 TCF80 TCF90 TCF100 Non-Indicating CUBEFuse 1 TCF1RN TCF3RN TCF6RN TCF10RN TCF15RN TCF17- /2RN TCF20RN TCF25RN TCF30RN TCF35RN TCF40RN TCF45RN TCF50RN TCF60RN TCF70RN TCF80RN TCF90RN TCF100RN 1-, 2- & 3-pole CCPB is an ampacity rejecting Carton Quantity and Weight branch disconnect for the Quik-Spec Coordination Panelboard that uses the CUBEFuse up to 100A. Amp Carton Weight Per Carton See Data Sheet 1160 Rating Qty. lbs kg TCF1-30A 12 1.39 0.63 TCF35-60A 12 1.42 0.65 TCF70-100A 6 1.74 0.79 0312 BU-SB11754 Page 1 of 2 Data Sheet 9000TCF and TCF RN Dimensions in (mm) Fuse Dimensions - in (mm) Amps A B C D E F G 1.88 0.75 1.00 0.23 0.04 0.63 0.28 1-15 (47.75) (19.05) (25.40) (5.84) (1.02) (15.93) (7.11) 1.88 0.75) 1.00 0.31 0.04 0.63 0.28 1 17 2 (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 1.88 0.75) 1.00 0.31 0.04 0.63 0.28 20 (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 1.88 0.75 1.00 0.31 0.04 0.63 0.28 25-30 (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 2.13 1.00 1.13 0.36 0.04 0.63 0.38 35-40 (54.10) (25.40) (28.58) (9.10) (1.02) (15.93) (9.65) 2.13 1.00 1.13 0.44 0.04 0.63 0.38 45-50 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 2.13 1.00 1.13 0.44 0.04 0.63 0.38 60 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 3.01 1.00 1.26 0.49 0.06 0.58 0.38 70 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 3.01 1.00 1.26 0.49 0.06 0.58 0.38 80-90 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 3.01 1.00 1.26 0.57 0.06 0.58 0.38 100 (76.45) (25.40) (32.00) (14.48) (1.60) (14.78) (9.65) Time-Current Characteristic CurvesAverage Melt Current Limitation Curves The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical informa- tion that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 2012 Cooper Bussmann www.cooperbussmann.com 0312 BU-SB11754 Page 2 of 2 Data Sheet 9000