Low-Peak CUBEFuse With and Without Indication Finger-Safe, Dual-Element, Time-Delay Class J Performance Fuse, 1-100A, 600Vac/300Vdc Catalog Numbers (amp rating) Indicating CUBEFuse 1 TCF6 TCF10 TCF15 TCF17- /2 TCF20 TCF25 TCF30 TCF35 TCF40 TCF45 TCF50 TCF60 TCF70 TCF80 TCF90 TCF100 Non-Indicating CUBEFuse 1 TCF1RN TCF3RN TCF6RN TCF10RN TCF15RN TCF17- /2RN TCF20RN TCF25RN TCF30RN TCF35RN TCF40RN TCF45RN TCF50RN TCF60RN TCF70RN TCF80RN TCF90RN TCF100RN Features and Product Benefits 70-100A Case Size 35-60A Case Size 1-30A Case Size The worlds first finger-safe power fuse system. Smallest footprint of any class fuse including Class J, CC, T and RK. Catalog Symbols: TCF Indicating fuse (6-100A) Meets Class J time-delay electrical performance requirements. TCF RN Non-indicating fuse (1-100A) Available with and without open fuse indication to meet every customer Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at requirement. 500% Rated Current The indicating version features easyID open fuse technology for faster Ampere Rating: 1 to 100A troubleshooting and reduced downtime. Voltage Rating: 600Vac/300Vdc Faster response to damaging faults to help reduce destructive thermal and Interrupting Rating: 300kA RMS Sym. (UL) magnetic forces. 200kA RMS Sym. (CSA) 100kA DC (UL & CSA) True dual-element fuse construction with a minimum of 10 seconds time- Agency Information: delay at 500% of rating. UL Listed Special Purpose Fuse: Guide JFHR, File E56412 Long time-delay minimizes nuisance circuit openings due to temporary CSA Certified Fuse: Class 1422- 02, File 53787 overloads and transient surges. CE compliance for the European Union low voltage directive High interrupting rating to safely interrupt faults up to 300kA. Other Ratings/Specifications: No venting of arc or molten metal and gases during opening. Watts Loss at rated current: TCF30: 3.99W Robust cycling and inrush current withstand. TCF60: 6.23W Low let-through currents under fault conditions. TCF100: 9.51W Provides Type 2 No Damage protection for IEC motors starters when Operating and Storage Temperature Range: 14 to 149F(-10 to 65C) properly sized. Material Specifications: Case: Glass filled PES (Polyethersulfone) Easy selective coordination with any other Cooper Bussmann Low-Peak Class L, J and RK1 fuse with simple 2:1 amp ration between upstream and Terminals: Copper alloy Terminal plating: Electroless tin downstream fuses. Indicator lens: PES (Polyethersulfone) (indicating version only) CUBEFuse Holders, Disconnects and Safety Switch Indicator: Energetic chemical The CUBEfuse is used in the following Cooper Bussmann products. Carton Quantity and Weight Amp Carton Weight Per Carton Rating Qty. lbs kg TCF1-30A 12 1.39 0.63 TCF35-60A 12 1.42 0.65 TCF70-100A 6 1.74 0.79 TCFH N 100, 60 & 30A Holders. CCP CF 1-, 2- & 3-Pole CCPB 1-, 2- & 3-Pole disconnects for CF Quik-Spec Safety Data Sheet 9007 switched disconnects the Quik-Spec Coordination Switch disconnect (optional Data Sheet 1157 Panelboard. Data Sheet 1160 window). Data Sheet 1156 0309 BU-SB09230 Page 1 of 2 Data Sheet 9000TCF and TCF RN Dimensions in (mm) Fuse Dimensions - in (mm) Amps A B C D E F G 1.88 0.75 1.00 0.23 0.04 0.63 0.27 1-15 (47.75) (19.05) (25.40) (5.84) (1.02) (15.88) (6.86) 1.88 0.75) 1.00 0.27 0.04 0.63 0.27 17.5-20 (47.75) (19.05) (25.40) (6.86) (1.02) (15.88) (6.86) 1.88 0.75 1.00 0.31 0.04 0.63 0.27 25-30 (47.75) (19.05) (25.40) (7.94) (1.02) (15.88) (6.86) 2.13 1.00 1.13 0.36 0.04 0.63 0.38 35-40 (54.10) (25.40) (28.58) (9.14) (1.02) (15.88) (9.65) 2.13 1.00 1.13 0.40 0.04 0.63 0.38 45-50 (54.10) (25.40) (28.58) (10.16) (1.02) (15.88) (9.65) 2.13 1.00 1.13 0.44 0.04 0.63 0.38 60 (54.10) (25.40) (28.58) (11.11) (1.02) (15.88) (9.65) 3.01 1.00 1.26 0.57 0.06 0.63 0.39 70-100 (76.45) (25.40) (32.00) (14.4) (1.60) (15.88) (9.93) Time-Current Characteristic CurvesAverage Melt Current Limitation Curves The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information con- tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 2009 Cooper Bussmann St. Louis, MO 63178 www.cooperbussmann.com 0309 BU-SB09230 Page 1 of 2 Data Sheet 9000