LTR REVISION DR CK AP AP DATE ECO No. NONE ENGINEERING RELEASE GH 09/14/99 A B 7028 CHANGE KICK GUARDS LS DK 28 MAY 02 C 7699 UPDATED FRONT PANEL LW DK 10 OCT 03 D 7907 COR. VOLTAGE RATINGS LW DK 28 MAY 04 E 8240 CHANGE TO BLACK CHASSISJ.O. 19 DEC 05 1. RACK MOUNTED, STEEL CHASSIS, BLACK MEDIUM TEXTURE 19.00 WIDTH STANDARD RACK MOUNTING 1.72 HEIGHT. 7.00 DEPTH. NOTE: CHASSIS SUPPORT BRACKETS OR SLIDES ARE REQUIRED 2. INPUT: 110-125 VAC OR 200-240 VAC, VOLTAGE SELECTABLE SINGLE-PHASE, 50/60 HZ. 16 AMP MAXIMUM TOTAL CURRENT. POWER INLET: IEC 320 C-20 INLET, RATED 16/20 AMP. 3. OUTPUT: 110-125 VAC OR 200-240 VAC, 12 IEC 320 C-13 RECEPTACLES, 4 OUTLETS PER SECTION, NO TIME DELAY BETWEEN EACH SECTION. 16 AMPS MAXIMUM TOTAL CURRENT. 4. CIRCUIT BREAKER: ONE 2-POLE, 20 AMP MAIN POWER, MAGNETIC, WITH HIGH INRUSH TIME DELAY. 5. INDICATOR LIGHT: 2 GREEN, ONE PER VOLTAGE RANGE, ON WHEN MAIN CIRCUIT BREAKER IS ON. 3 GREEN, ONE FOR EACH SECTION. 6. FILTER: EMI/RFI, 20AMP RATED, 50/60 HZ. COMMON MODE, LINE TO GROUND 7.00 DIFFERENTIAL MODE, LINE TO LINE 7. SPIKE & SURGE PROTECTION: LINE TO LINE 8. REMOTE I/O SWITCHING CONNECTOR MATES WITH AMP 1-480305-0 CONNECTOR WITH AMP 60620-1 PINS. SAMPLE EPO/START REMOTE STATION REMOTE CONNECTOR PIN 1 N.O. MOM CONTACT START/ POWER REQUEST PIN 2 N.C. MAINT CONTACT (EPO) EPO/ POWER OFF PIN 3 COMMON (NOT GROUND) COMMON (NOT GROUND) NOTE: THIS UNIT IS DESIGNED FOR REMOTE OPERATION. EVEN WHEN THEREMOTE/OFF/LOCA SWITCH IS SET TOLOCA THE UNIT STILL REQUIRES A POWER REQUEST FROM THE REMOTE PORTS. REMOTE START REQUIRES TWO CONDITIONS: 1) MAINTAINED CONTACT BETWEEN PINS 2 & 3 2) MOMENTARY CONTACT BETWEEN PINS 1 & 3 REMOTE POWER OFF/EPO REQUIRES OPENING OF MAINTAINED CONTACT BETWEEN PINS 2 & 3. THIS TURNS OFF SWITCHED OUTLETS REGARDLESS OF REMOTE SWITCH POSITION. FOR START UP OF ADDITIONAL LATCHING UNITS, TM SEQUENCE 115/230VAC POWER CONTROLLER CONNECT PINS 1 & 2 ON J3 (SEQUENCE PORT) TO ANY AVS 0N BOARD SWITCHED SECTIONS OFF ON R REMOTE PORT ON ANOTHER LATCHING UNIT. AUTO VOLTAGE SELECTION R PULIZZI DO NOT CONNECT TO ANOTHER SEQUENCE PORT. II O I 1.72 REMOTE LOCAL ENGINEERING, INC. www.pulizzi.com SEQUENCE PORT ACTIVATES 4 SECS AFTERSW 3 OUTLETS TURN ON. O I 115VAC 9. UL RECOGNIZED COMPONENTS WHERE APPLICABLE. 230VAC J1 J2 J3 OFF 1 2 3 19.00 PULIZZI ENGINEERING INC. R 3200 S. Susan Street, Santa Ana, CA 92704 CAGE CODE (714) 540-4229 Fax (714) 641-9062 70513 TITLE THE INFORMATION AND DESIGN DISCLOSED HEREIN WAS ORIGINATED DIMENSIONS IN INCHES ENGINEERING DRAWING BY AND IS THE PROPERTY OF PULIZZI ENGINEERING INC. PULIZZI TOLERANCES: ENGINEERING INC RESERVES ALL PATENT, PROPRIETARY, DESIGN, DECIMALS ANGLES TPC2365-LT ASSY 3090 MANUFACTURING, REPRODUCTION, USE AND SALE RIGHTS THERETO, .XX 0.5 .020 DRAWN BY: GH DWG FILENAME:TPC 2365 LT 3090E ME.DWG AND TO ANY ARTICLE DISCLOSED THEREIN, EXCEPT TO THE EXTENT UNLESS RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THE FOREGOING DOES .XXX SCALE SIZE SHEET DWG NO. REV OTHERWISE .010 NOT APPLY TO VENDOR PROPRIETARY PARTS. COPYRIGHT 2003 P.E.I. SPECIFIED 1:1 1 OF 1 TPC 2365 LT 3090E ME E D S S S W W W 1 2 3X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for eaton manufacturer: Other Similar products are found below : BK-MDL-3-R BK1-S506-500-R BK1-S506-6-3-R BK1-S506-2-R MPI4040R4-1R5-R TDC600-10A 89096-015 8946K153 8961K155 M22-DL-W-X0 M22-D-R-GB0/K11 M22-L-R/R M22S-ST-GB12 630NHG3B 63ET 6422 6580 CTX20-16-52LP-R CWL530FI CXM/CO/GP/R/BB 6HD36 714125 MBO-2 ESR5-NO-41-24VAC-DC 7314K36 7321K2 F02A-1-1/2A F02A-1-1/2AS F02A-1AS F02A- 2AS F02A-3/4A F03A250V12A F03B125V4A MCR-4 MDA-2-8/10-R MDA-30A MDA-V-1/16 F60C500V10AS F60C500V15AS 7563K84 7634K36 MDQ-3/16 MDQ-7/10 MDQ-V-1/10 MDQ-V-1-1/4 MDQ-V-1/16 MDQ-V-1/2 MDQ-V-1/4 MDQ-V-3/16 MDQ-V-3/8