Effective May 2017 Technical Data 2530 Supersedes March 2007 6125TD Time-delay surface mount fuse Environmental data Life test: MIL-STD-202, Method 108A, Test Condition D Load humidity: MIL-STD-202, Method 103B Moisture resistance: MIL-STD-202, Method 106E Terminal strength: MIL-STD-202, Method 211A Thermal shock: MIL-STD-202, Method 107D, air- to-air Case resistance: EIA/IS-722 Resistance to dissolution of metallization: ANSI Product features J-STD-002, Test D Mechanical shock: MIL-STD-202, Method 213B Time-delay surface mount fuse with exceptions per EIA/IS-722 Standard Satisfies the EIA/IS-722 Standard High frequency vibration: MIL-STD-202, Method Solder immersion compatible 204D, Test Condition D Resistance to solvents: MIL-STD-202, Method Agency information 215A UL Recognition Guide & File numbers: JDYX2 & E19180. Ordering CSA Component Acceptance: 053787 C 000 & Specify packaging and product code (i.e., Class No: 1422 30 TR1/6125TD500-R Soldering method ELECTRICAL CHARACTERISTICS Wave immersion: 260C, 10 Sec. max. % of Amp Rating Opening Time Infrared reflow: 260C, 30 Sec. max. 100% 4 Hours Minimum 200% 1 Second Minimum 200% 2-4 Seconds Typical 200% 60 Seconds Maximum SPECIFICATIONS Product Current Voltage Interrupting Resistance Typical Typical Code Rating Rating Rating* (ohms)** Melting Voltage 2 AC DC 125VAC 60VDC Typ. I t Drop 6125TD500-R 500mA 125V 60V 50A 50A 0.4025 0.716 245 mV 6125TD750-R 750mA 125V 60V 50A 50A 0.2350 1.07 250 mV 6125TD1-R 1A 125V 60V 50A 50A 0.1680 2.88 256 mV 6125TD1.5-R 1.5A 125V 60V 50A 50A 0.0630 2.35 125 mV 6125TD2-R 2A 125V 60V 50A 50A 0.0480 9.45 133 mV 6125TD2.5-R 2.5A 125V 60V 50A 50A 0.0350 16.2 130 mV 6125TD3-R 3A 125V 60V 50A 50A 0.0263 15.3 97 mV 6125TD3.5-R 3.5A 125V 60V 50A 50A 0.0195 14.5 95 mV 6125TD4-R 4A 125V 60V 50A 50A 0.0185 38.8 106 mV 6125TD5-R 5A 125V 60V 50A 50A 0.0133 34.4 100 mV 6125TD7-R 7A 125V 60V 50A 50A 0.0087 90.2 99 mV * AC Interrupting Rating (Measured at designated voltage, 100% power factor) DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source) ** DC Cold Resistance (Measured at 10% of rated current) 2 Typical Melting I t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds) Typical Voltage Drop (Measured at rated current after temperature stabilizes) Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.6125TD Technical Data 2530 Effective May 2017 Time-delay surface mount fuse TIME CURRENT CURVE mm Dimensions (inches) 2.6 3.0 Land Pattern (0.102) (0.118) 4.0 (0.157) 8.6 (0.338) PACKAGING CODE Packaging Code Description TR1 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch (177mm) reel per EIA Standard 481 Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Eaton Electronics Division 1000 Eaton Boulevard Cleveland, OH 44122 United States www.eaton.com/electronics 2017 Eaton Eaton is a registered trademark. All Rights Reserved Printed in USA All other trademarks are property Publication No. 2530 of their respective owners. May 2017